13 resultados para Micropattern gaseous detectors
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
The Compact Muon Solenoid (CMS) detector is described. The detector operates at the Large Hadron Collider (LHC) at CERN. It was conceived to study proton-proton (and lead-lead) collisions at a centre-of-mass energy of 14 TeV (5.5 TeV nucleon-nucleon) and at luminosities up to 10(34)cm(-2)s(-1) (10(27)cm(-2)s(-1)). At the core of the CMS detector sits a high-magnetic-field and large-bore superconducting solenoid surrounding an all-silicon pixel and strip tracker, a lead-tungstate scintillating-crystals electromagnetic calorimeter, and a brass-scintillator sampling hadron calorimeter. The iron yoke of the flux-return is instrumented with four stations of muon detectors covering most of the 4 pi solid angle. Forward sampling calorimeters extend the pseudo-rapidity coverage to high values (vertical bar eta vertical bar <= 5) assuring very good hermeticity. The overall dimensions of the CMS detector are a length of 21.6 m, a diameter of 14.6 m and a total weight of 12500 t.
Resumo:
The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 pb-1 of data collected in pp collisions at s = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV/c is above 95% over the whole region of pseudorapidity covered by the CMS muon system, < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeVc is higher than 90% over the full η range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100GeV/c and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV/c. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation. © 2012 IOP Publishing Ltd and Sissa Medialab srl.
Resumo:
We are presenting here p/n junctions obtained with a modified opened liquid-phase epitaxy (LPE) system, used to diffuse indium antimonide (InSb) doped with Cd over InSb doped with Te wafers, in order to make InSb infrared (IR) sensors. This technique has several advantages: the diffusion can be performed in bigger substrate areas improving the device production; this method decreases the device manipulation, decreasing human mistakes and increasing the process reproducibility. The opened LPE in this work produced sensors in the first case with vapor of the diffusion material, coming from a microholed carbon boat full of the diffusion material, over which is positioned the substrate at atmospheric pressure. In the second, the diffusion material is on the bottom of a quartz recipient, and the InSb/Te wafer works as its cover, and vacuum was used. The IR sensors produced with the first method measured 8.9 x 10(7) cm Hz(1/2)/W as detectivity value and higher IR spectral response at 4.6 mu m, and those produced with the second 2.8 x 10(9) cm Hz(1/2)/W, at 4.4 mu m. Besides the electrical-optical properties, the structural properties of diffused layers were investigated by X-ray diffraction (XRD), scanning electron and atomic force microscopy (SEM, AFM), energy-dispersive and secondary ion mass spectroscopy (EDS, SIMS). (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
The behavior of uniformly accelerated detectors in the Minkowski and Rindler vacua is analyzed when the detector is coupled to a scalar field during a finite amount of time T. We point out that the logarithmic ultraviolet divergences reported in the literature are due to the instantaneous switching of the detector. We explicitly show this by considering a detector switched on and off continuously. The usual Planckian spectrum for the excitation probability is recovered in the limit T --> infinity.
Resumo:
We analyze the response of Unruh-DeWitt detectors in the presence of inertial scalar sources. We show that, in general, a detector responds to the corresponding Coulomb field. However, in some cases, pure vacuum contributions can overwhelm the influence of the Coulomb field rendering the effect of the external source on the detector's response arbitrarily small. We revisit in this context the celebrated question of whether uniformly accelerated observers can see the radiation coming from an inertial charge, and point out the present impediments to answering this question.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
An experimental investigation of the noise generated by cavitation in turbulent shear flows produced by confined sharp-edge orifice-plates is reported. The acoustic source strength of cavitation was determined by means of reciprocity type measurements. Experimentally determined scaling parameters are applied to a model to prototype scaling formula derived from dimensional analysis. The proposed formula is checked experimentally. Comparative photographic observations of the cavitation patterns for two different values of gas content are presented. The observed sound reduction, that occurs when supersaturated conditions exist downstream the orifice-plates, is explained by the effects of gas diffusion into the cavitation bubbles, and by simple acoustic attenuation.
Resumo:
Mammals keep their body temperature (Tb) relatively constant even under a wide range of ambient temperature variation. However, in some particular situations it may be beneficial to increase or to decrease Tb. For instance, under hypoxic conditions, a regulated drop in Tb (anapyrexia) takes place which has been reported to be crucial for survival in a number of different species. This review highlights major advances in the research about nitric oxide (NO) and carbon monoxide (CO-where data are relatively less abundant), before focusing on the role played by these gaseous neuromediators in thermoregulation, under the conditions of euthermia and anapyrexia. Available data are consistent with the notion that both NO and CO, acting on the CNS, participate in thermoregulation, with NO decreasing Tb and CO increasing it. However further studies are required before definitive conclusions can be made as to their physiological mechanisms of action.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this paper we report on a search for short-duration gravitational wave bursts in the frequency range 64 Hz-1792 Hz associated with gamma-ray bursts (GRBs), using data from GEO 600 and one of the LIGO or Virgo detectors. We introduce the method of a linear search grid to analyze GRB events with large sky localization uncertainties, for example the localizations provided by the Fermi Gamma-ray Burst Monitor (GBM). Coherent searches for gravitational waves (GWs) can be computationally intensive when the GRB sky position is not well localized, due to the corrections required for the difference in arrival time between detectors. Using a linear search grid we are able to reduce the computational cost of the analysis by a factor of O(10) for GBM events. Furthermore, we demonstrate that our analysis pipeline can improve upon the sky localization of GRBs detected by the GBM, if a high-frequency GW signal is observed in coincidence. We use the method of the linear grid in a search for GWs associated with 129 GRBs observed satellite-based gamma-ray experiments between 2006 and 2011. The GRBs in our sample had not been previously analyzed for GW counterparts. A fraction of our GRB events are analyzed using data from GEO 600 while the detector was using squeezed-light states to improve its sensitivity; this is the first search for GWs using data from a squeezed-light interferometric observatory. We find no evidence for GW signals, either with any individual GRB in this sample or with the population as a whole. For each GRB we place lower bounds on the distance to the progenitor, under an assumption of a fixed GW emission energy of 10(-2)M circle dot c(2), with a median exclusion distance of 0.8 Mpc for emission at 500 Hz and 0.3 Mpc at 1 kHz. The reduced computational cost associated with a linear search grid will enable rapid searches for GWs associated with Fermi GBM events once the advanced LIGO and Virgo detectors begin operation.
Resumo:
The physics of plasmas encompasses basic problems from the universe and has assured us of promises in diverse applications to be implemented in a wider range of scientific and engineering domains, linked to most of the evolved and evolving fundamental problems. Substantial part of this domain could be described by R–D mechanisms involving two or more species (reaction–diffusion mechanisms). These could further account for the simultaneous non-linear effects of heating, diffusion and other related losses. We mention here that in laboratory scale experiments, a suitable combination of these processes is of vital importance and very much decisive to investigate and compute the net behaviour of plasmas under consideration. Plasmas are being used in the revolution of information processing, so we considered in this technical note a simple framework to discuss and pave the way for better formalisms and Informatics, dealing with diverse domains of science and technologies. The challenging and fascinating aspects of plasma physics is that it requires a great deal of insight in formulating the relevant design problems, which in turn require ingenuity and flexibility in choosing a particular set of mathematical (and/or experimental) tools to implement them.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)