123 resultados para Methylammonium lead iodide
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A new strategy for minimization of Cu2+ and Pb2+ interferences on the spectrophotometric determination of Cd2+ by the Malachite green (MG)-iodide reaction using electrolytic deposition of interfering species and solid phase extraction of Cd2+ in flow system is proposed. The electrolytic cell comprises two coiled Pt electrodes concentrically assembled. When the sample solution is electrolyzed in a mixed solution containing 5% (v/v) HNO3, 0.1% (v/v) H2SO4 and 0.5 M NaCl, Cu2+ is deposited as Cu on the cathode, Pb2+ is deposited as PbO2 on the anode while Cd2+ is kept in solution. After electrolysis, the remaining solution passes through an AG1-X8 resin (chloride form) packed minicolumn in which Cd2+ is extracted as CdCl4/2-. Electrolyte compositions, flow rates, timing, applied current, and electrolysis time was investigated. With 60 s electrolysis time, 0.25 A applied current, Pb2+ and Cu2+ levels up to 50 and 250 mg 1-1, respectively, can be tolerated without interference. For 90 s resin loading time, a linear relationship between absorbance and analyte concentration in the 5.00-50.0 μg Cd 1-1 range (r2 = 0.9996) is obtained. A throughput of 20 samples per h is achieved, corresponding to about 0.7 mg MG and 500 mg KI and 5 ml sample consumed per determination. The detection limit is 0.23 μg Cd 1-1. The accuracy was checked for cadmium determination in standard reference materials, vegetables and tap water. Results were in agreement with certified values of standard reference materials and with those obtained by graphite furnace atomic absorption spectrometry at 95% confidence level. The R.S.D. for plant digests and water containing 13.0 μg Cd 1-1 was 3.85% (n = 12). The recoveries of analyte spikes added to the water and vegetable samples ranged from 94 to 104%. (C) 2000 Elsevier Science B.V.
Resumo:
This paper reports a study regarding the distribution of lead in the organic matter fractions of a loamy oxisol treated with stable manure, and its effect on the soil microbial biomass. The experimental design was a completely randomized factorial with three replicates. Treatments were four lead (Pb) rates (0, 200, 400, and 600 mg kg(-1) soil), two levels of manure (0 and 30 Mg ha(-1)) and two sampling times (30 and 60 days after lead application). Total and soil lead soluble in Mehlich 1 extractant, and Ph in the different fractions of the organic matter (fulvic acid, humic acid, and residual) were evaluated along with the soil microbial biomass. Data showed that lead, applied as PbCl2, was concentrated in the residual fraction. The application of manure at the rate of 30 Mg ha(-1) did not affect lead distribution in the fractions until 60 days after incorporation. Lead extracted by Mehlich 1 increased as function of the quantity applied. Manure stimulated the growth of the soil microbial biomass which was reduced by the 200 mg kg(-1) doses of lead, with manure application, increasing, however, with larger rates. Mehlich 1 extracted only part of the lead present in the residual fraction.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Composite made of Lead Zirconate Titranate (PZT) ceramic powder and castor oil based polyurethane (PU) were prepared in the thin film form with 0-3 connectivity by spin coating. The composite films were obtained in the thickness range of 100 mum to 300 mum using 33-vol.% of ceramic. The samples mechanical resistance. The material was characterised by dielectric spectroscopy, thermally stimulated discharge current (TSDC), hysteresis measurements and laser-intensity-modulation method (LIMM). The pyroelectric coefficient at 343 K was 7x10(-5) C.m(-2) K-1 for the sample poled with 10 MV/m at 373 K for Ih. The results show that this new composite can be used as suitable piezo and pyroelectric sensors.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Tradicionalmente, os limites de tolerância biológica são utilizados exclusivamente para a promoção e a preservação da saúde dos trabalhadores, não sendo aplicados com fins diagnósticos. Entretanto, com relação a algumas intoxicações profissionais, o assunto é polêmico. Neste artigo, defende-se a utilização do limite de tolerância aplicado atualmente no Brasil à plumbemia como um critério importante para a realização do diagnóstico da intoxicação profissional pelo chumbo. Argumenta-se que, em oposição ao tradicional critério clínico, deve-se abordar o problema do diagnóstico da intoxicação pelo chumbo sob um ponto de vista epidemiológico, utilizando-se o atual valor do limite de tolerância para a plumbemia como um marcador de risco relativo significativamente aumentado.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)