38 resultados para Medicine, Experimental.

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: We describe an experimental model for transanal endorectal pull-through surgery using the method of de]a Torre and Ortega that can be used for training purposes in experimental laboratories.Methods: Ten rabbits were submitted to the transanal endorectal pull-through technique of de la Torre and Ortega. Animals were randomly selected in the Botucatu School of Medicine experimental laboratory. Animals weighted between 2800 and 4400 g. Colons were not prepared, and antibiotic therapy was not used; dipyrone(1) was administered postoperatively for analgesic purposes. We standardized resected segment size, recorded surgical time, and observed Survival and possible complications for 1 month.Results: All animals survived the initial follow-up period without infection. Bowel movements returned quickly, and all animals were evacuating regularly within the first 24 hours. Mean surgical time was 48.6 minutes.Conclusions: the experimental model proposed in this study is very useful for training and improving surgical techniques using the method of de la Torre and Ortega. The rabbit is an excellent animal for this surgery because of its size and postoperative resistance. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Autologous fibrin gel is commonly used as a scaffold for filling defects in articular cartilage. This biomaterial can also be used as a sealant to control small hemorrhages and is especially helpful in situations where tissue reparation capacity is limited. In particular, fibrin can act as a scaffold for various cell types because it can accommodate cell migration, differentiation, and proliferation. Despite knowledge of the advantages of this biomaterial and mastery of the techniques required for its application, the durability of several types of sealant at the site of injury remains questionable. Due to the importance of such data for evaluating the quality and efficiency of fibrin gel formulations on its use as a scaffold, this study sought to analyze the heterologous fibrin sealant developed from the venom of Crotalus durissus terrificus using studies in ovine experimental models. The fibrin gel developed from the venom of this snake was shown to act as a safe, stable, and durable scaffold for up to seven days, without causing adverse side effects. Fibrin gel produced from the venom of the Crotalus durissus terrificus snake possesses many clinical and surgical uses. It presents the potential to be used as a biomaterial to help repair skin lesions or control bleeding, and it may also be used as a scaffold when applied together with various cell types. The intralesional use of the fibrin gel from the venom of this snake may improve surgical and clinical treatments in addition to being inexpensive and adequately consistent, durable, and stable. The new heterologous fibrin sealant is a scaffold candidate to cartilage repair in this study.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This report evaluates the carotid artery exteriorization technique to allow repeated percutaneous artery catheterization in six brown brocket deer (Mazama gouazoubira). Repeated percutaneous catheterization of the carotid artery was possible for periods of 3 mo to obtain arterial blood and monitor arterial blood pressure of deer without risk of arterial rupture. The artery pulse was easily palpable for periods tip to 15 mo. Postoperative complication and/or arterial damage was not observed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: To physiologically reconstruct the biliary tract, Crema et al suggested the application of the Monti principle to the biliary tract, already used in humans for the urinary tract. With this technique, a jejunal segment is transversely retubularized. This study aimed to evaluate the efficacy of jejunal tube interposition between the common bile duct and duodenum in dogs.METHODS: Thirteen dogs underwent a laparoscopic common bile duct ligature, followed by a biliodigestive connection by jejunal tube interposition after one week. The levels of glutamic-pyruvic and glutamic-oxalacetic transaminases, total bilirubins, alkaline phosphatase and gamma-glutamyltransferase were assessed before surgery and thereafter weekly until euthanasia, which was performed 6 weeks after biliodigestive connection.RESULTS: Data on 9 dogs were analyzed statistically. The dogs presented with obstructive jaundice after common bile duct ligature, as confirmed by biochemical examination. They showed a statistically significant reduction in cholestasis after biliodigestive connection by jejunal tube interposition and were healthy until the end of the experiment.CONCLUSION: A statistically significant reduction was seen in total bilirubin and canalicular enzymes (alkaline phosphatase and gamma-glutamyltransferase) in the 9 dogs 6 weeks after biliodigestive conviction by jejunal tube interposition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Research in humans has demonstrated that high serum iron (sFe) concentration can predispose to infection, and many infections subsequently result in alterations of host sFe. A decrease in sFe concentration is an early and sensitive indicator of systemic inflammation caused by tissue necrosis, bacterial infections, or endotoxemia in horses. Serum iron parameters in acute equine herpesvirus type 1 (EHV-1) infection have not been evaluated previously. Objectives To document the sFe response to EHV-1 infection and to determine whether or not significant differences in sFe concentration exist between EHV-1 infected horses that develop neurologic disease and those that do not. Animals A total of 14 horses experimentally infected with EHV-1. Methods Data were collected as an ancillary data set during a blinded experimental EHV-1 infection. Horses were infected with the rAb4 strain of EHV-1. Temperature, neurologic score, packed cell volume (PCV), and sFe parameters (sFe concentration, % saturation, and total iron-binding capacity) were recorded daily for 2weeks. Data were evaluated using Wilcoxon signed rank tests and Wilcoxon rank sum tests with Bonferroni corrections. Conclusions and Clinical Relevance Serum iron concentration decreases significantly in a biphasic pattern after EHV-1 infection. There was no significant difference in sFe concentration in horses that developed neurologic disease and those that did not in these experimentally infected animals. Serum iron parameters may be useful in monitoring the clinical course of viral infections such as EHV-1.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate the rat alveolar socket response to implanted polyethylene tubes filled with a light-cured MTA or Angelus MTA.Study design. Fifty-seven Wistar rats received an implant filled with one of the materials in the dental socket of the right central incisor. After 30, 60, and 90 days, animals were killed, and the right hemimaxillas were removed and processed to be analyzed on light microscopy. After embedding in paraffin, 6-mu m-thick sections were obtained and stained with hematoxylin and eosin. Qualitative and quantitative analyses of the reaction were performed.Results. It was observed that the light-cured MTA presented a similar response compared with Angelus MTA, characterized by the reduction of the chronic inflammatory response and organization of the alveolar bone close to the materials, especially at the 90th day of observation.Conclusions. It was concluded that both materials were well accepted by the alveolar tissue of rats, with the formation of mineralized tissue close to the materials. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e93-e97)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate the pH, calcium release, setting time, and solubility of two commercially available mineral trioxide aggregate (MTA) cements (white MTA Angelus and MTA Bio), and of three experimental cements (light-cured MTA, Portland cement with 20% bismuth oxide and 5% calcium sulfate, and an epoxy resin-based cement).Study design. For evaluation of pH and calcium ion release, polyethylene tubes with 1.0 mm internal diameter and 10.0 mm length were filled with the cements and immediately immersed in flasks containing 10 mL deionized water. After 3, 24, 72, and 168 hours, the tubes were removed and the water from the previous container was measured for its pH and calcium content with a pH meter and an atomic absorption spectrophotometer. For analysis of the setting time, Gilmore needles weighing 100 g and 456.5 g were used, in accordance with the American Society for Testing and Materials specification no. C266-03. Solubility of each cement was also tested.Results. All the cements were alkaline and released calcium ions, with a declining trend over time. After 3 hours, Portland cement + bismuth oxide and MTA Bio had the highest pH and light-cured MTA the lowest. After 1 week, MTA Bio had the highest pH and light-cured MTA and epoxy resin-based cement the lowest. Regarding calcium ion release, after 3 hours, Portland cement + bismuth oxide showed the highest release. After 1 week, MTA Bio had the highest. Epoxy resin-based cement and light-cured MTA had the lowest calcium release in all evaluation periods. Regarding setting times, white MTA Angelus and MTA Bio had the shortest, Portland cement + bismuth oxide had an intermediate setting time, and the epoxy resin-based cement had the longest. The materials that showed the lowest solubility values were the epoxy resin-based cement, Portland cement + bismuth oxide, and light-cured MTA. The highest solubility values were presented in white MTA Angelus and MTA Bio.Conclusions. The white MTA Angelus and MTA Bio had the shortest setting times, higher pH and calcium ion release, and the highest solubility. In contrast, the epoxy resin-based cement and light-cured MTA showed lower values of solubility, pH, and calcium ion release. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 110: 250-256)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)