35 resultados para Matsushita Electric Industrial Co.

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEB

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we present the results of the use of a methodology for multinodal load forecasting through an artificial neural network-type Multilayer Perceptron, making use of radial basis functions as activation function and the Backpropagation algorithm, as an algorithm to train the network. This methodology allows you to make the prediction at various points in power system, considering different types of consumers (residential, commercial, industrial) of the electric grid, is applied to the problem short-term electric load forecasting (24 hours ahead). We use a database (Centralised Dataset - CDS) provided by the Electricity Commission de New Zealand to this work.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The addition of different dopants affects the densification, mean grain size and electrical properties of TiO2-based varistor ceramics. This paper discusses the microstructural and electrical properties of (Ta, Co, Pr) doped TiO2 systems, demonstrating that some of these systems display electrical properties that allow for their use as low voltage varistor. Dopants such as Ta2O5 play a special role in the formation of barriers at the grain boundary and in the nonlinear behavior in TiO2-based systems. The higher values of nonlinear coefficient and breakdown electric field were obtained in the system just doped with Ta2O5 and CoO.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The sol-gel method combined with a spin-coating technique has been successfully applied for the preparation of rare-earth doped silica:germania films used for the fabrication of erbium-doped waveguide amplifiers (EDWA), presenting several advantages over other methods for the preparation of thin films. As with other methods, the sol-gel route also shows some drawbacks, such as cracks related to the thickness of silica films and high hydrolysis rate of certain precursors such as germanium alkoxides. This article describes the preparation and optical characterization of erbium and ytterbium co-doped SiO2:GeO2 crack-free thick films prepared by the sol-gel route combined with a spin-coating technique using a chemically stable non-aqueous germanium oxide solution as an alternative precursor. The non-crystalline films obtained are planar waveguides exhibiting a single mode at 1,550 nm with an average thickness of 3.9 mu m presenting low percentages of porosity evaluated by the Lorentz-Lorenz Effective Medium Approximation, and low stress, according to the refractive index values measured in both transversal electric and magnetic polarizations. Weakly confining core layers (0.3% < Delta n < 0.75%) were obtained according to the refractive index difference between the core and buffer layers, suggesting that low-loss coupling EDWA may be obtained. The life time of the erbium I-4(13/2) metastable state was measured as a function of erbium concentration in different systems and based on these values it is possible to infer that the hydroxyl group was reduced and the formation of rare-earth clusters was avoided.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three pig genetics lineages A, B and C marketed in Brazil, were stunning with the manual electric stunning (Karl Schermer 220-230/250 volts, 45-60 Hz and 1.4 - 1.5 A) and the collective gaseous system (COMBI-BUTINA 90% CO 2). The electric stunning provided higher blood splashed levels in the areas of the inside round (0.477 and 0.26, p ≤ 0.01), shoulder/cranial (0.154 and 0.039, p ≤ 0.005), shoulder/central (0.261 e 0.052, p ≤ 0.001), shoulder/caudal (0.180 and 0.030, p ≤ 0.01), loin/central (0.185 and 0.065, p ≤ 0.01), loin/caudal (0.06 and 0.207, p ≤ 0.01) and loin/lateral external (0.061 and 0.013, p ≤ 0.05), as well as more diffuse blood splashed in the areas of the inside round (0.461 and 0.279, p ≤ 0.05), shoulder/cranial (0.154 and 0.039, p ≤ 0.001), shoulder/central (0.231 and 0.039, p ≤ 0.001) and shoulder/caudal (0.185 and 0.026, p ≤ 0.001). The electric stunning also provided higher skin damage levels in the areas of the shoulder (1.098 and 0.795, p ≤ 0.001), body (1.04 and 0.948, p ≤ 0.05) and ham (0.84 and 0.68, p ≤ 0.001), as well as higher eyelid reflex levels (11.57%) comparatively to the gaseous system (2.86%) of a total of 426 pigs. Small indexes of bone fractures and muscle bruises were found in both systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pigs of three genetics lineages A, B and C marketed in Brazil, with alive weight from 100 to 120 kg were submitted to the manual electric stunning (Karl Schermer 220-230/250 volts, 45-60 Hz and 1.4 -1.5 A) and to the collective gaseous system (COMBI-BUTINA 90% CO 2). Blood samples, for levels determination of creatine phosphokinase (CPK), lactate and cortisol, as well as samples of the semimembranosus muscle (10 g) for the determination of the gene halothane, were collected. Being compared the electric and gaseous stunning systems, the electric stunning did demonstrate to be more stressful providing larger plasmatic concentrations of cortisol (p ≤ 0.001) and lactate (p ≤ 0.001) for the genetic lineages A and C, in the studied conditions. However it didn't observe significant differences beween the sanguine indicators and stunning systems in subject when the lineage B was considered. Significant differences among the genetic lineages A, B and C were obtained being compared the plasmatic values of creatine phosphokinase (p ≤ 0.001), lactate (p ≤ 0.001) and cortisol (p ≤ 0.001) when stunned with the gaseous system, however when the electric system was used only the cortisol values presented significant differences (p ≤ 0.001). The presence of the gene halothane (Nn) was only observed in the lineage B.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: This crossover study compared the efficacy of an ultrasonic toothbrush for the reduction of plaque, gingival inflammation, and levels of Streptococcus mutans, in relation to an electric and a manual toothbrush. Materials and Methods: Twenty-one patients with orthodontic appliances were divided into three groups. All patients were evaluated by a periodontist and samples of saliva were collected for quantification of S mutans. The patients received their first brushes with appropriate instructions. For each crossover leg, patients used each toothbrush for a period of 30 days. At the end of each washout period, participants received a periodontal evaluation and new samples of saliva were collected. After 15 days of using their own toothbrushes, patients received the next toothbrushes in the experimental sequence. Results: The ultrasonic brush group presented significant improvement in the reduction of visible plaque on the buccal surfaces (-6.36%, P = .007). The counts of S mutans decreased in the electric (2.04 × 105 to 1.36 × 105 colony-forming units [CFU]/mL) and ultrasonic (2.98 × 105 to 1.84 × 105 CFU/mL) groups. There were no statistical differences among the three brushes for the clinical and microbiological parameters evaluated. Conclusions: This study did not demonstrate that the ultrasonic toothbrush was better in reducing gingival inflammation in adolescent orthodontic patients, but plaque scores were lowered on buccal surfaces of teeth with orthodontic brackets. In addition, S mutans counts were markedly decreased in the electric and ultrasonic groups, which should be related to a reduced risk of oral disease. © 2006 by The EH Angle Education and Research Foundation, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work has as objectives the implementation of a intelligent computational tool to identify the non-technical losses and to select its most relevant features, considering information from the database with industrial consumers profiles of a power company. The solution to this problem is not trivial and not of regional character, the minimization of non-technical loss represents the guarantee of investments in product quality and maintenance of power systems, introduced by a competitive environment after the period of privatization in the national scene. This work presents using the WEKA software to the proposed objective, comparing various classification techniques and optimization through intelligent algorithms, this way, can be possible to automate applications on Smart Grids. © 2012 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Geociências e Meio Ambiente - IGCE

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA