77 resultados para MANDIBULAR ANGLE FRACTURE

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fractures of the mandibular angle deserve particular attention because they represent the highest percentage of mandibular fractures and have the highest postsurgical complication rate, making them the most challenging and unpredictable mandibular fractures to treat. Despite the evolution in the treatment of maxillofacial trauma and fixation methods, no single treatment modality has been revealed to be ideal for mandibular angle fractures. Several methods of internal fixation have been studied with great variation in complications rates, especially postoperative infections. Recently, new studies have shown reduction of postsurgical complications rates using three-dimensional plates to treat mandibular angle fractures. Nevertheless, only few surgeons have used this type of plate for the treatment of mandibular angle fractures. The aim of this clinical report was to describe a case of a patient with a mandibular angle fracture treated by an intraoral approach and a three-dimensional rectangular grid miniplate with 4 holes, which was stabilized with monocortical screws. The authors show a follow-up of 8 months, without infection and with occlusal stability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the clinical outcome of patients with mandibular angle fractures treated by intraoral access and a rectangular grid miniplate with 4 holes and stabilized with monocortical screws.Patients and Methods: This study included 45 patients with mandibular angle fractures from the Department of Oral and Maxillofacial Surgery São Paulo State University, Araraquara, Brazil, and from the Clinic of Oral and Maxillofacial Surgery at the University of Frankfurt, Germany. The 45 fractures of the mandibular angle were treated with a rectangular grid miniplate of a 2.0-mm system by an intraoral approach with monocortical screws. Clinical evaluations were postoperatively performed at 15 and 30 days and 3 and 6 months, and the complications encountered were recorded and treated.Results: The infection rate was 4.44% (2 patients), and in 1 patient it was necessary to replace hardware. This patient also had a fracture of the left mandibular body; 3 patients (6.66%) had minor occlusal changes that have been resolved with small occlusal adjustments. Before surgery, 15 patients (33.33%) presented with hypoesthesia of the inferior alveolar nerve; 4 (8.88%) had this change until the last clinical control, at 6 months.Conclusions: The rectangular grid miniplate used in this study was stable for the treatment of simple mandibular angle fractures through intraoral access, with low complication rates, easy handling, and easy adjustment, with a low cost. Concomitant mandibular fracture may increase the rate of complications. This plate should be indicated in fractures with sufficient interfragmentaty contact. (C) 2011 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 69:1436-1441, 2011

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This in vitro study evaluated the influence of the type of miniplate and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy's osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to four groups (n = 15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0 mm miniplates and 2.0 mm x 6 mm rnonocortical screws. In groups 1 and 2, two conventional (G1) or locking (G2) screws were installed in each bone segment using a conventional (G1) or a locking (02) straight miniplate; in groups 3 and 4, three conventional (03) or locking (04) screws were installed in the proximal segment and four conventional (G3) or locking (04) screws were installed in the distal segment using a conventional (G3) or a locking (G4) seven-hole straight miniplate. The hemimandibles were loaded in compressive strength until a 4 mm displacement occurred between the segments, vertically or horizontally. Locking plate/screw systems provided significantly greater resistance to displacement than conventional ones (p < .01). Locking miniplates offered more resistance than conventional miniplates. Long locking miniplates provided greater stability than short ones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As every surgical procedure extraction of third molars can result in several complications, among them the mandibular angle fracture. Predisposing factors for fracture should be analyzed during and after the surgery. This paper aims to discuss the predisposing factors to the occurrence of mandibular angle fractures during and after the procedure for third molars extraction, as well as surgical principles to avoid this complication.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to perform a physicochemical and morphological characterization and compare the mechanical behavior of an experimental Ti-Mo alloy to the analogous metallic Ti-based fixation system, for mandibular angle fractures. Twenty-eight polyurethane mandibles were uniformly sectioned on the left angle. These were divided into 4 groups: group Eng 1P, one 2.0-mm plate and 4 screws 6 mm long; group Eng 2P, two 2.0-mm plates, the first fixed with 4 screws 6 mm long and the second with 4 screws 12 mm long. The same groups were created for the Ti-15Mo alloy. Each group was subjected to linear vertical loading at the first molar on the plated side in a mechanical testing unit. Means and standard deviations were compared with respect to statistical significance using ANOVA. The chemical composition of the Ti-15Mo alloy was close to the nominal value. The mapping of Mo and Ti showed a homogeneous distribution. SEM of the screw revealed machining debris. For the plates, only the cpTi plate undergoes a surface treatment. The metallographic analysis reveals granular microstructure, from the thermomechanical trials. A statistically significant difference was found (P < 0.05) when the comparison between both internal fixation techniques was performed. The 2P technique showed better mechanical behavior than 1P.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study aims to compare three types of internal fixation for fractures of the mandibular angle. Mechanical testing was performed on replicas of polyurethane hemimandibles sectioned at the angle region to simulate a fracture and fixed with three different hardwares. Fixation devices enrolled on this survey included the grid plates with and without an intermediate bar and the method described by Champy and colleagues in 1978 and the sample consisted of 10 hemimandibles for each group. Vertical loadings were applied on each hemimandible and recorded after a vertical displacement of 3 and 5 mm. Statistical analysis was made by means of the variance analysis (ANOVA) and the Duncan test with a significance level of 5%. The Champy technique showed a statistically significant increased resistance when compared to the grid plates after vertical displacements of 3 and 5 mm. The results of this survey suggest that the Champy technique, when compared to the grid plate positioned at the middle of the mandibular bone (placement site selected for this study), is more resistant than the grid plate and that the inclusion or not of an intermediate bar to the grid plates does not improve its resistance after linear vertical loadings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mandibular fractures are the injury most commonly found in the facial bones. They have varied etiology, such as automobile, motorcycle and cycling accidents, physical abuse and falls. The choice of treatment of mandibular fractures most often employed is the reduction and fixation of bone fragments. Regarding fractures involving the mandibular angle, access headgear is the most widely used, in view of the action of masticatory muscles causing greater displacement of fractured stumps. Therefore, the proposal to introduce a conservative approach and facilitated for the treatment of fractures of the mandibular angle, as well as to demystify the contraindication to intraoral approach cases unfavorable fracture displacement, this work is to report a clinical casesurgical mandibular angle fracture, treated by intraoral approach. The fracture was fixed with two plates, one following the external oblique line system (1.5 mm) and a lower system (2.0 mm), with the help of percutaneous trocar. This approach is very promising for these cases, in order to ease the technical as well as by reducing the technical complications of extraoral approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The treatment of mandibular fractures has undergone many changes, especially after the introduction of rigid internal fixation techniques. Currently, the use of resorbable materials presents some advantages over metallic devices, particularly when applied in children. Objective: The authors discuss the controversies involved in the treatment of mandibular fractures in children, mainly related to fixation of fractures. Case Report: In this paper, we present a case of a 5 years treatment patient with mandibular angle fracture treated by open reduction and internal fixation with plates and screws. Final Comments: Aiming to not interfere in the development of tooth germs and mandibular bone growth a second surgery for removal of the fixation devices is indicated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to gather data on trauma etiology and mandibular fracture localization in patients who presented at the General Hospital of Nova Iguacu, Rio de Janeiro, Brazil. From March 2007 to December 2008, 95 patients with mandibular fracture were registered in a medical form, at the Bucomax-illofacial Surgery Department of the General Hospital of Nova Iguacu, Rio de Janeiro, Brazil. Concerning mandibular fracture etiology, 21.05% were caused by motorcycle accidents, followed by interpersonal violence without use of weapons (punches, kicks, bumps with the head, blows with the elbow, etc) (16.84%) and interpersonal violence with firearm (14.73%). It was found that 52.63% of the patients had a single fracture line. The most affected fracture area was the parasymphysis (26.02%), followed by the condyle (22.60%) and mandibular angle (18.49%). Concerning the injury area, 24.21% were directed to the mandibular symphysis, 22.17% of the patients did not remember the injury area, and 18.94% had multiple injuries. When the injury was directed to the symphysis, the result was more condyle fractures (11.64%), and injuries at the mandibular angle resulted in fractures at the angle itself (8.90%). The most common fracture cause was traffic accidents, mainly motorcycle accidents, and the most affected areas were the parasymphysis and the condyle. The mandible isolated fractures occurred in half of the cases. Motorcycle accidents resulted in more fractures in the parasymphysis area, and when the symphysis area is affected by injuries, the result is a higher percentage in condyle fractures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our goal was to study the use of 2.0-mm miniplates for the fixation of mandibular fractures. Records of 191 patients who experienced a total of 280 mandibular fractures that were treated with 2.0-mm miniplates were reviewed. One hundred twelve of those patients, presenting 160 fractures, who attended a late follow-up were also clinically evaluated. Miniplates were used in the same positions described by AO/ASIF. No intermaxillary fixation was used. All patients included had a minimum follow-up of 6 months. Demographic data, procedures, postoperative results, and complications were analyzed. Mandibular fractures occurred mainly in males (mean age, 30.3 years). Mean follow-up was 21.92 months. The main etiology was motor vehicle accident. The most common fracture was the angle fracture (28.21%). Twenty-two fractures developed infection, for an overall incidence of 7.85%. When only angle fractures are considered, that incidence is increased to 18.98%. Although only 1 patient (0.89%) described inferior alveolar nerve paresthesia, objective testing revealed sensitivity alterations in 31.52% of the patients who had fractures in regions related to the inferior alveolar nerve. Temporary mild deficit of the marginal mandibular branch was observed in 2.56% of the extraoral approaches performed and 2.48% presented with hypertrophic scars. Incidence of occlusal alterations was 4.0%. Facial asymmetry was observed in 2.67% of the patients, whereas malunion incidence was 1.78%. Fibrous union, mostly partial, occurred in 2.38% of the fractures, but only 1 of those presented with mobility (0.59%). Condylar resorption developed in 6.25% of the fixated condylar fractures. Mean mouth opening was 42.08 mm. The overall incidence of complications, including infections, was similar to those described for more rigid methods of fixation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: the purpose of the present study was to evaluate the histologic results of bone cavities that were surgically created in the mandibles of Cebus apella monkeys and filled with autogenous bone, PerioGlas, FillerBone, or Bone Source. Materials and Methods: Surgical cavities 5 mm in diameter were prepared through both mandibular cortices in the mandibular angle region. The cavities were randomly filled, and the animals were divided into groups according to the material employed: Group 1 cavities were filled with autogenous corticocancellous bone; group 2 cavities were filled with calcium phosphate cement (BoneSource); and group 3 and group 4 cavities were filled with bioactive glass (FillerBone and PerioGlas, respectively). After 180 days the animals were sacrificed, and specimens were prepared following routine laboratory procedures for hematoxylin/eosin staining and histologic evaluation. Results: the histologic analysis showed that autogenous bone allowed total repair of the bone defects; bioactive glasses (FillerBone and PerioGlas) allowed total repair of the defects with intimate contact of the remaining granules and newly formed bone; and the cavities filled with calcium phosphate cement (BoneSource) were generally filled by connective fibrous tissue, and the material was almost totally resorbed. Discussion: the autogenous bone, FillerBone, and PerioGlas provided results similar to those in the current literature, showing that autogenous bone is the best Choice for filling critical-size defects. Synthetic implanted materials demonstrated biocompatibility, but the bioglasses demonstrated osteoconductive activity that did not occur with calcium phosphate (BoneSource). Conclusion: According to the methodology used in this study, it can be concluded that the utilization of autogenous bone and bioactive glasses permitted the repair of surgically created critical-size defects by newly formed bone; the synthetic implanted materials demonstrated biocompatibility, and the bioactive glasses demonstrated osteoconductive activity. The PerioGlas was mostly resorbed and replaced by bone and the remaining granules were in close contact with bone; the FillerBone showed many granules in contact with the newly formed bone; BoneSource did not permit repair of the critical-size defects, and the defects were generally filled by connective fibrous tissue.