4 resultados para M mode echocardiography

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

1. A method for obtaining the end-systolic left ventricular (LV) pressure-diameter and stress-diameter relationships in man was critically analyzed.2. Pressure-diameter and stress-diameter relationships were determined throughout the cardiac cycle by combining standard LV manometry with M-mode echocardiography. Nine adult patients with heart disease and without heart failure were studied during intracardiac catheterization under three different conditions of arterial pressure, i.e., basal (B) condition (mean +/- SD systolic pressure, 102 +/- 10 mmHg) and two stable states of arterial hypertension (H(I), 121 +/- 12 mmHg; H(II), 147 +/- 17 mmHg) induced by venous infusion of phenylephrine after parasympathetic autonomic blockade with 0.04 mg/kg atropine.3. Significant reflex heart rate variation with arterial hypertension was observed (B, 115 +/- 20 bpm; H(I), 103 +/- 14 bpm; H(II), 101 +/- 13 bpm) in spite of the parasympathetic blockade with atropine. The linear end-systolic pressure-diameter and stress-diameter relationships ranged from 53.0 to 160.0 mmHg/cm and from 97.0 to 195.0 g/cm3, respectively.4. The end-systolic LV pressure-diameter and stress-diameter relationship lines presented high and variable slopes. The slopes, which are indicators of myocardial contractility, are susceptible to modifications by small deviations in the measurement of the ventricular diameter or by delay in the pressure curve recording.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE--To provide a critical analysis of the fluid filled manometric system and M-mode echocardiography and, by their association, to standardize the determination of left ventricular (LV) pressure-diameter and stress-diameter relationships in humans. MATERIAL AND METHODS--The pressure curve and the LV M-mode image was obtained in 24 patients with cardiopathy. The dynamic characteristics of the fluid-filled system have been studied to define the amplitude, the resonance and the time gap of the pressure curve register. The delay of the pressure curve recording was determined in all cases by comparing pressure curve and echocardiographic aortic valve registers. The values of pressure, diameter, posterior wall thickness and LV meridional stress was calculated at every 0.02s. RESULTS--Preliminary analyses of the fluid-filled manometric system indicated that this system has variable dynamic characteristics. The pressure-diameter and stress-diameter loops obtained were similar to those of the literature. The values of end-systolic stress, percentage of fractional shortening, ejection fraction and circumferential fiber shortening rate of patients with dilated cardiomyopathy (n = 5) were significantly reduced when compared to the values of patients without left ventricular overload (n = 8) and patients with ventricular volume overload. It has been verified, also, that the retard of the pressure curve record introduced by the fluid-filled manometric system does not modify the values of these variables. CONCLUSION--The LV pressure-diameter and stress-diameter relationships obtained by the association of echocardiography and LV manometry showed functional characteristics of the ventricle that could not appear by the use of the echocardiography or by the LV manometry themselves.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective - To evaluate plication of the free wall of the left ventricle, which reduces the left ventricular area and volume, as a method to improve the left ventricular systolic function without cardiopulmonary bypass. Animals - 8 mixed-breed adult dogs. Procedure - Dilated cardiomyopathy (DCM) was induced in each dog by administration of doxorubicin (30 mg/m2, IV, q 21 d for 168 days). Two dogs died during induction of cardiomyopathy. Plication surgery was performed in 4 dogs. Two dogs did not ondergo to surgery (control group). Values for cardiac output (CO), 2-dimensional and M-mode echocardiography, arterial blood pressure, electrocardiography, blood cell counts, and serum biochemical analyses were recorded after induction of DCM (baseline) and 1, 2, 7, 15, 21, 30, 60, 90, 120, 150, and 180 days after plication surgery. Ambulatory ECG (Holter) recordings were conducted for 24 hours on the day of surgery. Results - 1 dog died after plication surgery. The remaining dogs undergoing ventricular plication had a significant improvement in CO, ejection fraction, and fractional shortening and reductions of left ventricular area and volume after surgery. Electrocardiographic and Holter recordings revealed premature ventricular complexes, which resolved without treatment during the first week after surgery. Clinical condition of the control dogs declined, and these 2 dogs died approximately 40 days after induction of cardiomyopathy. Conclusions and Clinical Relevance - Plication of the free wall of the left ventricle improved left ventricular systolic function in dogs with doxorubicin-induced cardiomyopathy. Additional studies are needed to evaluate its application in dogs with naturally developing DCM.