87 resultados para Lung Compliance
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
The surgical removal of the post-hepatic septum (PHS) in the tegu lizard, Tupinambis merianae, significantly reduces resting lung volume (VLr) and maximal lung volume (VLm) when compared with tegus with intact PHS. Standardised for body mass (MB), static lung compliance was significantly less in tegus without PHS. Pleural and abdominal pressures followed, like ventilation, a biphasic pattern. In general, pressures increased during expiration and decreased during inspiration. However, during expiration pressure changes showed a marked intra- and interindividual variation. The removal of the PHS resulted in a lower cranio-caudal intracoelomic pressure differential, but had no effect on the general pattern of pressure changes accompanying ventilation. These results show that a perforated PHS that lacks striated muscle has significant influence on static breathing mechanics in Tupinambis and by analogy provides valuable insight into similar processes that led to the evolution of the mammalian diaphragm. © 2003 Elsevier Science B.V. All rights reserved.
Resumo:
Background. The best way to study compensatory lung growth (CLG) is in a transplant without rejection. Since immunosuppressive drugs may influence CLG, it is better to not use them. Therefore we studied CLG in a reimplant of only one lobe after its removal. The objective was to compare lobar transplant CLG with CLG after lobectomy.Methods. Forty eight dogs were distributed in three groups: G1 = control, G2 = left cranial lobectomy, and G3 = left pneumonectomy with reimplantation of the caudal lobe. Five months after surgery the animals underwent lung scintigraphy and were sacrificed for morphometric study.Results. There was no correlation between scintigraphy and lung mass or lung volume. There was both mass and residual volume CLG in the operated groups, both contralateral and ipsilateral to surgery. There was no compensation for total lung capacity or compliance in the remaining caudal lobe (G2) or the reimplanted caudal lobe (G3) at 5 months after surgery. There was more damage in the reimplanted lobe. As previous studies have shown that CLG starts with increased mass and residual volume and compliance is compensated later. This study seemed to document the beginning of CLG, with lung compliance being the limiting factor of CLG at 5 months.Conclusion. There was CLG in both the reimplanted lobe and the contralateral lung, but compliance was still reduced. CLG was similar in both groups, but in the implanted lobe compliance was more prejudiced.
Resumo:
OBJETIVO: Avaliar se existe crescimento compensatório pulmonar em transplante lobar e verificar se este crescimento é semelhante ao que ocorre após lobectomia. MÉTODOS: Foram utilizados 48 cães, distribuídos em 3 grupos (G1=controle, G2=lobectomia cranial esquerda e G3=pneumonectomia com reimplante do lobo caudal esquerdo). Após 5 meses da cirurgia, os animais foram submetidos à cintilografia pulmonar e a seguir sacrificados para estudo morfométrico pulmonar. RESULTADOS: Os resultados mostraram que não existe correlação da cintilografia nem com a massa nem com o volume do pulmão. Houve crescimento compensatório em massa e volume residual nos dois grupos operados, tanto no pulmão contralateral como no ipsilateral à cirurgia, não existindo até os 5 meses de estudo compensação em capacidade pulmonar total, nem em complacência pulmonar no lobo caudal remanescente do G2 e no lobo caudal reimplantado do G3, havendo maior prejuízo para o lobo reimplantado. Como estudos prévios mostram que o crescimento compensatório pulmonar se inicia com aumento da massa e do volume residual, e que a complacência é compensada posteriormente, este estudo parece ter documentado o início do crescimento compensatório, sendo a complacência pulmonar o fator limitante do crescimento compensatório após 5 meses de estudo. CONCLUSÃO: Conclui-se que existe crescimento compensatório tanto no lobo reimplantado como no pulmão contralateral, mas a complacência ainda encontra-se reduzida. O crescimento compensatório foi semelhante nos dois grupos, mas a complacência do lobo implantado está mais prejudicada.
Resumo:
OBJECTIVE: To evaluate the effects of 2 different doses of exogenous surfactant on pulmonary mechanics and on the regularity of pulmonary parenchyma inflation in newborn rabbits. METHOD: Newborn rabbits were submitted to tracheostomy and randomized into 4 study groups: the Control group did not receive any material inside the trachea; the MEC group was instilled with meconium, without surfactant treatment; the S100 and S200 groups were instilled with meconium and were treated with 100 and 200 mg/kg of exogenous surfactant (produced by Instituto Butantan) respectively. Animals from the 4 groups were mechanically ventilated during a 25-minute period. Dynamic compliance, ventilatory pressure, tidal volume, and maximum lung volume (P-V curve) were evaluated. Histological analysis was conducted using the mean linear intercept (Lm), and the lung tissue distortion index (SDI) was derived from the standard deviation of the means of the Lm. One-way analysis of variance was used with a = 0.05. RESULTS: After 25 minutes of ventilation, dynamic compliance (mL/cm H2O.kg) was 0.87 +/- 0.07 (Control); 0.49 +/- 0.04 (MEC*); 0.67 +/- 0.06 (S100); and 0.67 +/- 0.08 (S200), and ventilatory pressure (cm H2O) was 9.0 +/- 0.9 (Control); 16.5 +/- 1.7 (MEC*); 12.4 +/- 1.1 (S100); and 12.1 +/- 1.5 (S200). Both treated groups had lower Lm values and more homogeneity in the lung parenchyma compared to the MEC group: SDI = 7.5 +/- 1.9 (Control); 11.3 +/- 2.5 (MEC*), 5.8 +/- 1.9 (S100); and 6.7 +/- 1.7 (S200) (*P < 0.05 versus all the other groups). CONCLUSIONS: Animals treated with surfactant showed significant improvement in pulmonary mechanics and more regularity of the lung parenchyma in comparison to untreated animals. There was no difference in results after treatment with either of the doses used.
Resumo:
BACKGROUND AND OBJECTIVES: Pressure controlled ventilation (PCV) is available in anesthesia machines, but there are no studies on its use during CO 2 pneumoperitoneum (CPP). This study aimed at evaluating pressure-controlled ventilation and hemodynamic and ventilatory changes during CPP, as compared to conventional volume controlled ventilation (VCV). METHODS: This study involved 16 dogs anesthetized with thiopental, fentanyl and pancuronium, which were randomly assigned to two groups: VC - volume controlled ventilation (n=8) and PC - pressure controlled ventilation (n=8). Hemodynamic and ventilatory parameters were monitored and recorded in 4 moments: M1 (before CPP), M2 (30 minutes after CPP = 10 mmHg), M3 (30 minutes after CPP=15 mmHg) and M4 (30 minutes after deflation). RESULTS: With CPP, there has been significant increase in tidal volume in PC group; there has been increase in airway pressures (peak and plateau), decrease in compliance with increase in CPP pressure, increase in heart rate, maintenance of mean blood pressure with higher values in the VC group in all stages; there was also increase in right atrium pressure with significant decrease after deflation, decrease in arterial pH with minor variations in PC group, greater arterial pCO 2 stability in PC group, and no significant changes in arterial pO 2. CONCLUSIONS: There were some differences in hemodynamic and ventilatory data between both ventilation control modes (VC and PC). It is possible to use pressure controlled ventilation during CPP, but the anesthesiologist must monitor and take a close look at alveolar ventilation, adjusting inspiratory pressure to ensure proper CO 2 elimination and oxygenation. © Sociedade Brasileira de Anestesiologia, 2005.
Resumo:
Pós-graduação em Fisiopatologia em Clínica Médica - FMB
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In patients with acute respiratory distress syndrome, positive end-expiratory pressure is associated with alveolar recruitment and lung hyperinflation despite the administration of a low tidal volume. The best positive end-expiratory pressure should correspond to the best compromise between recruitment and distension, a condition that coincides with the best respiratory elastance.
Resumo:
Objective: To compare the efficiency of an Aeroneb Pro vibrating plate and an Atomisor MegaHertz ultrasonic nebulizer for providing ceftazidime distal lung deposition.Design: In vitro experiments. One gram of cetazidime was nebulized in respiratory circuits and mass median aerodynamic diameter of particles generated by ultrasonic and vibrating plate nebulizers was compared using a laser velocimeter. In vivo experiments. Lung tissue concentrations and extrapulmonary depositions were measured in ten anesthetized ventilated piglets with healthy lungs that received 1 g of ceftazidime by nebulization with either an ultrasonic (n = 5), or a vibrating plate (n = 5) nebulizer.Setting: A two-bed Experimental Intensive Care Unit of a University School of Medicine.Intervention: Following sacrifice, 5 subpleural specimens were sampled in dependent and nondependent lung regions for measuring ceftazidime lung tissue concentrations by high-performance liquid chromatography.Measurements and results: Mass median aerodynamic diameters generated by both nebulizers were similar with more than 95% of the particles between 0.5 and 5 mu m. Lung tissue concentrations were 553 +/- 123 [95% confidence interval: 514-638] mu g g(-1) using ultrasonic nebulizer, and 452 +/- 172 [95% confidence interval: 376-528] mu g g(-1) using vibrating plate nebulizers (NS). Extrapulmonary depositions were, respectively, of 38 +/- 5% (ultrasonic) and 34 +/- 4% (vibrating plate) (NS).Conclusions: Vibrating plate nebulizer is comparable to ultrasonic nebulizers for ceftazidime nebulization. It may represent a new attractive technology for inhaled antibiotic therapy.
Resumo:
Purpose of reviewLung ultrasound at the bedside can provide accurate information on lung status in critically ill patients with acute respiratory distress syndrome.Recent findingsLung ultrasound can replace bedside chest radiography and lung computed tomography for assessment of pleural effusion, pneumothorax, alveolar- interstitial syndrome, lung consolidation, pulmonary abscess and lung recruitment/de-recruitment. It can also accurately determine the type of lung morphology at the bedside (focal or diffuse aeration loss), and therefore it is useful for optimizing positive end-expiratory pressure. The learning curve is brief, so most intensive care physicians will be able to use it after a few weeks of training.SummaryLung ultrasound is noninvasive, easily repeatable and allows assessment of changes in lung aeration induced by the various therapies. It is among the most promising bedside techniques for monitoring patients with acute respiratory distress syndrome.
Resumo:
The aim this study was to evaluate systolic and diastolic function in volume overload induced myocardial hypertrophy in rats.Volume overload myocardial hypertrophy was induced in thirteen male Wistar rats by creating infrarenal arteriovenous fistula (AVF). The results were compared with a SHAM operated group (n = 11). Eight weeks after surgery, tail-cuff blood pressure was recorded, then rats were sacrificed for isolated heart studies using Langendorffs preparation.AVF rats presented increased left and right ventricular weights, compared to controls. The increased normalized ventricular volume (V0/LVW, 0.141 +/- 0.035 mL/g vs. 0.267 +/- 0.071 mL/g, P < 0.001) in the AVF group indicated chamber dilation. Myocardial hydroxyproline concentration remained unchanged. There was a significant decrease in +dP/dt (3318 +/- 352 mm Hg s(-1) vs. 2769 +/- 399 mm Hg s(-1); P=0,002), end-systolic pressure-volume relation (246 +/- 56 mm Hg mL(-1) vs. 114 +/- 63 mm Hg mL(-1);, P < 0,001), and -dP/dt (1746 +/- 240 min Hg s(-1) vs. 1361 +/- 217 mm Hg s(-1), P < 0.001) in the AVF group, which presented increased ventricular compliance (Delta V-25: SHAM=0.172 +/- 0.05 mL vs. AVF=0.321 +/- 0.072 mL, P < 0.001) with preserved myocardial passive stiffness (Strain(25): SHAM=13.5 +/- 3.0% vs. AVF=12.3 +/- 1.9%, P > 0.05).We conclude that volume-overload induced hypertrophy causes myocardial systolic and diastolic dysfunction with increased ventricular compliance. These haemodynamic features help to explain the long-term compensatory phase of chronic volume overload before transition to overt congestive heart failure. (c) 2006 European Society of Cardiology. Published by Elsevier B.V. All rights reserved.
Resumo:
Scorpaena plumieri venomous fish inflicted severe injuries in humans characterized by systemic effects and cardiovascular abnormalities. Although cardiotoxic and hypotensive effects induced in rats by this venom have been studied, little is known about their effect on bronchial epithelial permeability and airway inflammation in mice. The primary goal of this study was to determine whether the intraplantar or intraperitoneal injection of S. plumieri venom results in systemic response, and whether this event initiates acute lung injure. We found that BALB/c mice developed neutrophilic infiltrates, areas of lung hemorrhage and alveolar macrophage activation within 24 h after injection with S. plumieri venom. These histopathological changes were associated with an early increase in BAL fluid protein and early induction of cytokines, chemokines and matrix metaloproteinases, followed by a later increase in BAL fluid neutrophils. These findings provide clear evidence that the injection of S. plumieri venom in footpad or peritoneal cavity of mice results in venom deposition in the airway and initiates a sustained inflammatory response in the lungs. (C) 2007 Elsevier Ltd. All rights reserved.