25 resultados para Locking
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
This in vitro study evaluated the influence of the type of miniplate and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy's osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to four groups (n = 15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0 mm miniplates and 2.0 mm x 6 mm rnonocortical screws. In groups 1 and 2, two conventional (G1) or locking (G2) screws were installed in each bone segment using a conventional (G1) or a locking (02) straight miniplate; in groups 3 and 4, three conventional (03) or locking (04) screws were installed in the proximal segment and four conventional (G3) or locking (04) screws were installed in the distal segment using a conventional (G3) or a locking (G4) seven-hole straight miniplate. The hemimandibles were loaded in compressive strength until a 4 mm displacement occurred between the segments, vertically or horizontally. Locking plate/screw systems provided significantly greater resistance to displacement than conventional ones (p < .01). Locking miniplates offered more resistance than conventional miniplates. Long locking miniplates provided greater stability than short ones.
Resumo:
Purpose: The aim of this in vitro study was to assess the biomechanical stability of 9 different osteosynthesis methods after sagittal split ramus osteotomy by simulating the masticatory forces and using a 3-point biomechanical test method.Materials and Methods: Forty-five polyurethane hemimandibles with bone-like consistency were randomly assigned to 9 groups (n = 5) and subjected to sagittal split ramus osteotomy. After 4-mm advancement of the distal segment, the bone segments were fixed by different osteosynthesis methods using 2.0-mm miniplate/screw systems: group A, one 4-hole conventional straight miniplate; group B, one 4-hole locking straight miniplate; group C, one 4-hole conventional miniplate and one bicortical screw; group D, one 4-hole locking miniplate and 1 bicortical screw; group E, one 6-hole conventional straight miniplate; group F, one 6-hole locking straight miniplate; group (3: two 4-hole conventional straight miniplates; group H. two 4-hole locking straight miniplates; and group 1, 3 bicortical screws in an inverted-L. pattern. All models were mounted on a base especially constructed for this purpose. Using a 3-point biomechanical test model, the hemimandibles were loaded in compressive strength in an Instron machine (Norwood, MA) until a 3-mm displacement occurred between segments vertically or horizontally. Data were analyzed by analysis of variance and Tukey test (alpha = 1%).Results: The multiparametric comparison of the groups showed a statistically significant difference (P<.01) between groups that used 2 miniplates (groups G and H), 1 miniplate and 1 bicortical screw (groups C and D), and only bicortical screws (group D compared with groups that used only 1 miniplate with 2 screws per segment (groups A and B) and 3 screws per segment (groups E and F).Conclusion: The placement of 2.0-mm-diameter bicortical screws in the retromolar region, associated or not with conventional and locking miniplates with monocortical screws, promoted a better stabilization of bone segments. Locking miniplates presented a better performance in bone fixation in all groups. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:724-730, 2010
Resumo:
The superposition of optical interference patterns in a photoresist film can produce a rich variety of diffractive structures. In particular, a periodic non-sinusoidal surface relief profile can be synthesized by adding the Fourier components (sinusoidal gratings) of the desired profile. In order to control the shape of the grooves it is very important an accurate adjustment of the relative spatial shift between the recorded sinusoidal components. We describe the implementation of an opto-electronic feedback loop to select and lock such spatial shift at any desired position, thus allowing the synthesis of structures varying from symmetrical to asymmetrical relief profiles in a continuous range. To demonstrate the feasibility of the technique, the Fourier synthesis of two spatial harmonics is accomplished. The superposed sinusoidal gratings were recorded in positive photoresist films using a holographic setup operating at the line lambda = 457.9 run of an argon-ion laser. A detailed description of the procedure as well as the resulting profiles recorded in the photoresist is presented. (C) 2002 Elsevier B.V. B.V. All rights reserved.
Resumo:
Atrophic mandible fractures are frequently a challenge to stabilize. This study evaluated, through mechanical testing in vitro, the number of locking screws that is sufficient to withstand loading when applied with a locking reconstruction plate in the fixation of atrophic mandible fractures. Polyurethane mandibles with a simulated linear fracture at the midline were used as substratum. Results show that resistance of the fixation is poor when one and two screws are used on each side of the fracture. Three screws on each side of the fracture significantly increases the resistance to displacement. However, no additional strength is added to the construct when more than three screws per side are used. © 2013 International Association of Oral and Maxillofacial Surgeons.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: Avaliar o método de Ulson de fixação intramedular associado à fixação externa variando a altura do travamento externo dos fios de Kirschner e sem fixação externa. MÉTODO: Foram utilizadas 18 tíbias de porcos, sendo realizada osteotomia transversal na região da tuberosidade e introduzidos dois fios de Kirschner intramedulares em cada peça, em três diferentes padrões de montagem: grupo I - travamento com minifixador externo com 3,0cm de altura; grupo II - travamento com 4,5cm de altura; grupo III: sem travamento externo. Realizaram-se ensaios mecânicos de cisalhamento, obtendo-se: carga máxima, limite de proporcionalidade e coeficiente de rigidez. RESULTADOS: Não foram encontradas diferenças significativas de carga máxima e limite de proporcionalidade entre os grupos; o grupo II apresentou maior coeficiente de rigidez. CONCLUSÃO: A altura do travamento dos fios de Kirschner no método de Ulson, dentro dos limites avaliados, não prejudicou a estabilidade do sistema de fixação da fratura.
Resumo:
This study verified the resistance to displacement of six miniplate fixation methods after sagittal split osteotomy (SSO). SSO was performed in 30 polyurethane synthetic mandible replicas. The distal segments were advanced (4 mm) and specimens were grouped according to the fixation method: four-hole standard miniplate; four-hole locking miniplate; six-hole standard miniplate; six-hole locking miniplate; six-hole standard sagittal miniplate; six-hole locking sagittal miniplate. Biomechanical evaluation was performed by applying compression loads to three points on the second molar region, using an Instron universal testing machine until a 3 mm displacement of the segments occurred. Compression loads able to produce 3 mm displacement were recorded in kN and subjected to analysis of variance (P < 0.01) and Tukey's tests for comparison between groups (P < 0.05). The locking sagittal miniplate showed higher resistance to displacement than the regular four- and six-hole locking and standard miniplates. No significant differences were observed between the locking sagittal miniplate and the regular sagittal or the four-hole locking miniplates. Two of the three groups with the best results had locking plate fixation methods. Fixation of SSO with a single miniplate is better accomplished using six-hole locking sagittal miniplates, six-hole standard sagittal miniplates, or four-hole locking miniplates; these methods are more resistant to displacement.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this work we study the basic aspects concerning the stability of the outer satellites of Jupiter. Including the effects of the four giant planets and the Sun we study a large grid of initial conditions. Some important regions where satellites cannot survive are found. Basically these regions are due to Kozai and other resonances. We give an analytical explanation for the libration of the pericenters (ω) over bar - (ω) over bar (J). Another different center is also found. The period and amplitude of these librations are quite sensitive to initial conditions, so that precise observational data are needed for Pasiphae and Sinope. The effect of Jupiter's mass variation is briefly presented. This effect can be responsible for satellite capture and also for locking (ω) over bar - (ω) over bar (J) in temporary libration.
Resumo:
A minimalist representation of protein structures using a Go- like potential for interactions is implemented to investigate the mechanisms of the domain swapping of p13suc1, a protein that exists in two native conformations: a monomer and a domain- swapped dimer formed by the exchange of a beta- strand. Inspired by experimental studies which showed a similarity of the transition states for folding of the monomer and the dimer, in this study we justify this similarity in molecular descriptions. When intermediates are populated in the simulations, formation of a domain- swapped dimer initiates from the ensemble of unfolded monomers, given by the fact that the dimer formation occurs at the folding/ unfolding temperature of the monomer ( T-f). It is also shown that transitions, leading to a dimer, involve the presence of two intermediates, one of them has a dimeric form and the other is monomeric; the latter is much more populated than the former. However, at temperatures lower than T-f, the population of intermediates decreases. It is argued that the two folded forms may coexist in absence of intermediates at a temperature much lower than T-f. Computational simulations enable us to find a mechanism, `` lock- and- dock'', for domain swapping of p13suc1. To explore the route toward dimer formation, the folding of unstructured monomers must be retarded by first locking one of the free ends of each chain. Then, the other free termini could follow and dock at particular regions, where most intrachain contacts are formed, and thus de. ne the transition states of the dimer. The simulations also showed that a decrease in the maximum distance between monomers increased their stability, which is explained based on confinement arguments. Although the simulations are based on models extracted from the native structure of the monomer and the dimer of p13suc1, the mechanism of the domain- swapping process could be general, not only for p13suc1.
Resumo:
The consequences of the use of embedded crack finite elements with uniform discontinuity modes (opening and sliding) to simulate crack propagation in concrete are investigated. It is shown the circumstances in which the consideration of uniform discontinuity modes is not suitable to accurately model the kinematics induced by the crack and must be avoided. It is also proposed a technique to embed cracks with non-uniform discontinuity modes into standard displacement-based finite elements to overcome the shortcomings of the uniform discontinuity modes approach.
Resumo:
A general technique to embed non-uniform displacement discontinuities into standard solid finite elements is presented. The technique is based on the decomposition of the kinematic fields into a component related to the deformation of the solid portion of the element and one related to the rigid-body motion due to a displacement discontinuity. This decomposition simplifies the incorporation of discontinuity interfaces and provides a suitable framework to account for non-uniform discontinuity modes. The present publication addresses two families of finite element formulations: displacement-based and stress hybrid finite element. © 2005 Elsevier Ltd. All rights reserved.
Resumo:
STUDY DESIGN. Observational cohort study. OBJECTIVE. To investigate spinal coordination during preferred and fast speed walking in pain-free subjects with and without a history of recurrent low back pain (LBP). SUMMARY OF BACKGROUND DATA. Dynamic motion of the spine during walking is compromised in the presence of back pain (LBP), but its analysis often presents some challenges. The coexistence of significant symptoms may change gait because of pain or adaptation of the musculoskeletal structures or both. A history of LBP without the overlay of a current symptomatic episode allows a better model in which to explore the impact on spinal coordination during walking. METHODS. Spinal and lower limb segmental motions were tracked using electromagnetic sensors. Analyses were conducted to explore the synchrony and spatial coordination of the segments and to compare the control and subjects with LBP. RESULTS. We found no apparent differences between the groups for either overall amplitude of motion or most indicators of coordination in the lumbar region; however, there were significant postural differences in the mid-stance phase and other indicators of less phase locking in controls compared with subjects with LBP. The lower thoracic spinal segment was more affected by the history of back pain than the lumbar segment. CONCLUSION. Although small, there were indicators that alterations in spinal movement and coordination in subjects with recurrent LBP were due to adaptive changes rather than the presence of pain. © 2013, Lippincott Williams & Wilkins.