25 resultados para Line design

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The use of non-pressure compensating drip hose in horticultural and annual cycle fruits is growing in Brazil. In this case, the challenge for designers is getting longer lateral lines with high values of uniformity. The objective of this study was to develop a model to design longer lateral lines using non-pressure compensating drip hose. Using the developed model, the hypotheses to be evaluated were: a) the use of two different spacing between emitters in the same lateral line allows longer length; b) it is possible to get longer lateral lines using high values of pressure variation in the lateral lines since the distribution uniformity stays below allowable limits. A computer program was developed in Delphi based on the model developed and it is able to design lateral lines in level using non-pressure compensating drip hose. The input data are: desired distribution uniformity (DU); initial and final pressure in the lateral line; coefficients of relationship between emitter discharge and pressure head; hose internal diameter; pipe cross-sectional area with the dripper; and roughness coefficient for the Hazen-Williams equation. The program allows calculate the lateral line length with three possibilities: selecting two spacing between emitters and defining the exchange point; using two pre-established spacing between emitters and calculating the length of each section with different spacing; using one emitter spacing. Results showed that the use of two sections with different spacing between drippers in the lateral line didn't allow longer length but got better uniformity when compared with lateral line with one spacing between emitters. The adoption of two spacing increased the flow rate per meter in the final section which represented approximately 80% of the lateral line total length and this justifies their use. The software allowed DU above 90% with pressure head variation of 40% and the use of two spacing between emitters. The developed model/software showed to be accurate, easy to handle and useful for lateral line design using non-pressure compensating drip hose.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A presente pesquisa teve como objetivo estudar os efeitos fitotóxicos de fungicidas, acaricidas e inseticidas e algumas associações entre eles, em plantas de mamoeiros (Carica papaya L.) cv. Sunrise Solo Improved Line 72/12, em condições de campo, no município de São Mateus -- ES, pertencente à maior região produtora do Estado. O experimento foi arranjado em delineamento de blocos casualizados, com 4 repetições e 03 plantas úteis por parcela. Foram utilizados os seguintes produtos, com as respectivas doses, para cada 100 L de água: chlorothalonil (Daconil PM-200g); mancozeb (Dithane PM -- 200g); oxicloreto de cobre (Reconil -- 400g); thiabendazole (Tecto 450 -- 100ml); dicofol + tetradifon (Carbax -- 200ml); triazophós (Hostathion 400 BR -- 150ml); óxido de fenbutatina (Torque 500 SC -- 60ml); e abamectin (Vertimec 18 CE -- 50ml): Analisou-se a fitotoxicidade dos produtos testados, em relação à altura da planta, nº de folhas, número de flores e frutos ; diâmetro do caule e queimaduras ou injúrias foliares. As datas das avaliações foram: 01 dia antes das pulverizações, 15 dias e 30 dias após as mesmas. Os fungicidas Daconil BR, Reconil e Tecto 450; o fungicida acaricida Dithane PM; os acaricidas Carbax e Torque 500 SC; e o inseticida-acaricida Vertimec 18 CE, aplicados isoladamente, não afetaram o crescimento e a produção das plantas, nem causaram injúrias nas folhas das mesmas. A associação de fungicidas e fungicida-acaricida, com os acaricidas, ou inseticida-acaricida, não mostrou nenhum efeito fitotóxico sobre os parâmetros de crescimento avaliados, nem causaram queimaduras ou injúrias foliares.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Estudaram-se os efeitos fitotóxicos de fungicidas, acaricidas e inseticidas e algumas associações entre eles, em plantas de mamoeiros (Carica papaya L.) cv. Sunrise Solo Improved Line 72/12, em condições de verão, no município de São Mateus - ES, localizado na região produtora do Estado. O experimento foi arranjado em delineamento de blocos casualizados, com 4 repetições e 03 plantas úteis por parcela experimental. Foram utilizados os seguintes produtos, com as respectivas doses, para cada 100 l de água: abamectin (Vertimec 18 CE - 50 ml); dicofol + tetradiphon (Carbax - 200 ml), fenbutatin oxide (Torque 500 SC - 60 ml); mancozeb (Dithane PM - 200g); oxicloreto de cobre (Reconil - 400g) e thiabendazole (Tecto 450 - 100ml). Analisou-se a fitotoxicidade dos produtos em relação à altura da planta, nº de folhas, número de flores e frutos ; diâmetro do caule e queimaduras ou injúrias foliares. As medições e contagens foram feitas um dia antes das pulverizações, 15 e 30 dias após. Constatou-se que o Vertimec 18 CE, associado ao Reconil ou ao Tecto 450, ocasionou leves injúrias foliares, detectadas aos 15 dias após as pulverizações, que se tornaram praticamente imperceptíveis, aos 30 dias após as pulverizações; e que Dithane PM, Reconil, Tecto 450, Carbax, Torque 500 SC, Dithane PM + Carbax, Dithane PM + Torque 500 SC, Dithane PM + Vertimec 18 CE, Reconil + Carbax, Reconil + Torque 500 SC, Tecto 450 + Carbax e, Tecto 450 + + Torque 500 SC não interferiram nos parâmetros de desenvolvimento e de produção estudados, bem como não causaram injúrias ou queimaduras nas folhas dos mamoeiros.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work has as objective to develop an interesting research line in the Optical Instrumentation area, that is to associate the Optical Design to the Ophthalmology area. The purpose of it is handling the optical design techniques to design a widely used ophthalmologic instrument called slit lamp. The optical and mechanical design of the slit lamp prototype was carefully projected in order to improve the best quality image, the comfort of the patient and the user, the simplicity of handling, the facility of production the availability of optical and mechanical components in the national market and the low cost of production. The main goal of this work was to realize a project using totally national technology, cheapening the cost and forming the optimum image required for the slit lamp optical system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper explains the conceptual design of instrumentation that measures electric quantities defined in the Std. 1459-2000. It is shown how the instantaneous-space-phasor approach, based on alpha, beta, 0 components, can be used to monitor electric energy flow, evaluate the utilization of transmission line, and quantify the level of harmonic pollution injected by nonlinear loads.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When an area to be irrigated has a high slope gradient in the manifold line direction, an option is to use a tapered pipeline to economize on pipe costs and to keep pressure head variations within desired limits. The objective of this paper is to develop a linear optimization model to design a microirrigation system with tapered, downhill manifold lines, minimizing the equivalent annual cost of the hydraulic network and the annual pumping cost, and maximizing the emission uniformity previously established to the subunit. The input data are irrigation system layout, cost of all hydraulic network components, and electricity price. The output data are equivalent annual cost, pipeline diameter in each line of the system, pressure head in each node, and total operating pressure head. To illustrate its capability, the model is applied in a citrus orchard in Sao, Paulo State, Brazil, considering slopes of 3, 6, and 9%. The model proved to be efficient in the design of the irrigation system in terms of the emission uniformity desired.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the search for new therapeutic tools against tuberculosis two novel iron complexes, [Fe(L-H)3], with 3-aminoquinoxaline-2-carbonitrile N(1),N(4)-dioxide derivatives (L) as ligands, were synthesized, characterized by a combination of techniques, and in vitro evaluated. Results were compared with those previously reported for two analogous iron complexes of other ligands of the same family of quinoxaline derivatives. In addition, the complexes were studied by cyclic voltammetry and EPR spectroscopy. Cyclic voltammograms of the iron compounds showed several cathodic processes which were attributed to the reduction of the metal center (Fe(III)/Fe(II)) and the coordinated ligand. EPR signals were characteristic of magnetically isolated high-spin Fe(III) in a rhombic environment and arise from transitions between m(s) = +/- 1/2 (geff-9) or m(s) = +/- 3/2 (g(eff)similar to 4.3) states. Mossbauer experiments showed hyperfine parameters that are typical of high-spin Fe(III) ions in a not too distorted environment. The novel complexes showed in vitro growth inhibitory activity on Mycobacterium tuberculosis H(37)Rv (ATCC 27294), together with very low unspecific cytotoxicity on eukaryotic cells (cultured murine cell line J774). Both complexes showed higher inhibitory effects on M. tuberculosis than the "second-line" therapeutic drugs. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper explains the conceptual design of instrumentation that measures electric quantities defined in the trial-use Std. 1459-2000. It is shown how the Instantaneous-Space-Phasor (ISP) approach, based on α, β, 0 components, can be used to monitor electric energy flow, evaluate the utilization of transmission line and quantify the level of harmonic pollution injected by nonlinear loads.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The present study evaluated the cytotoxic effects of hard setting applied on the odontoblastlike cells MDPC-23. Study design: Eighty round-shaped samples were prepared with the following experimental materials: calcium hydroxide, Vitrebond, RelyX Luting, and RelyX Unicem. The samples were placed in serum-free culture medium and incubated for 24 hours or 7 days at 37°C with 5% CO 2 and 95% air. The odontoblast cells were plated in the wells and incubated for 72 hours. After this period, the complete culture medium was replaced by the extracts obtained from every sample, and the methyltetrazolium assay was carried out to evaluate the cell metabolism. Results: For the 24-hour period, the experimental materials calcium hydroxide, Vitrebond, RelyX Luting, and RelyX Unicem decreased the cell metabolic activity by 91.52%, 81.14%, 78.17%, and 2.64%, respectively. For the 7-day period, calcium hydroxide, Vitrebond, RelyX Luting, and RelyX Unicem decreased the metabolic activity of the MDPC-23 cells by 91.13%, 87.27%, 79.04%, and 10.51%, respectively. Conclusion: RelyX Unicem presented the lowest cytopathic effects to the cultured odontoblast cell line. © 2007 Mosby, Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multipulse rectifiers can replace a conventional six pulse three-phase rectifier (diode bridge) providing a DC voltage with low ripple, low Total Harmonic Distortion of current (THDi) and a high Power Factor (PF). In this context is presented a multipulse rectifier with generalized Delta-differential autotransformer topology, which can provide any level of DC output voltage for any level of three-phase AC input voltage. This paper presents all the possible configurations for Delta topology in order to choose, through graphics, one configuration that presents reduced weight and volume. The average voltage on the DC bus must be compatible with the DC voltage in the six pulse rectifier used in commercial ASDs. Therefore, it is possible to apply the retrofit technique to replace the conventional bridge rectifier by the proposed multipulse rectifier. Based on mathematic models and simulation results, an 18-pulse rectifier with Delta topology, 220 V of line voltage, 315 V of DC output, and rating 2.5 kW of power was designed, implemented and applied for three different commercial ASDs. Experimental results as voltage and current waveforms and results about PF and THDi will be presented. © 2012 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This research aims to investigate a topic sometimes overlooked among the research of ergonomics. Particularly, we treat the garments as personal protective equipment. In this study we abode on clothing produced and used in Brazil, making notes about the management of occupational safety for the use of such equipment. In turn, identify Relevant requirements for the design of personal protective equipment used in Brazil, in line with what is being studied in global forums on the subject. © 2013 Taylor & Francis Group.