83 resultados para Laser Dye Rhodamine B

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents the study of substrate surface effects on rhodamine B-containing silica films obtained from TEOS (tetraethylorthosilicate) acid hydrolysis. Soda-lime glass substrates were treated with basic solution under different reaction times and temperatures. Rhodamine B-containing silica films were deposited on pre-treated substrates by the spin-coating method. The substrate surface directly affects film morphology and homogeneity. The films are formed by packed silica spheres which protect the dye against acid-base attack. Luminescence spectra present shifts on the dye emission maximum as expected for different pH values on the substrate surface depending on the alkaline treatment. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Semiconductor-mediated photocatalytic oxidation is an interesting method for water decontamination and a specially modified TiO2 is said to be a promising material. This study verified that the synthesis of 1wt%Ag modified-Sc0.01Ti0.99O1.995 powder samples prepared by Polymeric Precursor Method is capable of forming a mixture of anatase-rutile phase with high photocatalytic performance. This kind of material is found to have a lower bandgap compared to the TiO2-anatase commercial powders, which can be associated to an innovative hybrid modification. The simultaneous insertion of scandium in order to generate a p-type semiconductor and a metallic silver nanophase acting as an electron trapper demonstrated being capable of enhancing the degradation of rhodamine B compared to the commercial TiO2. In spite of the different thermal treatments or phase amounts, the hybrid modified powder samples showed higher photocatalytic activity than the commercial ones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Semiconductor-mediated photocatalytic oxidation is an interesting method for water decontamination and a specially modified TiO2 is said to be a promising material. This study verified that the synthesis of 1wt%Ag modified-Sc0.01Ti0.99O1.995 powder samples prepared by Polymeric Precursor Method is capable of forming a mixture of anatase-rutile phase with high photocatalytic performance. This kind of material is found to have a lower bandgap compared to the TiO2-anatase commercial powders, which can be associated to an innovative hybrid modification. The simultaneous insertion of scandium in order to generate a p-type semiconductor and a metallic silver nanophase acting as an electron trapper demonstrated being capable of enhancing the degradation of rhodamine B compared to the commercial TiO2. In spite of the different thermal treatments or phase amounts, the hybrid modified powder samples showed higher photocatalytic activity than the commercial ones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The sensitized photolysis of [Ru(NH3)(6)](2+) by the organic dye rhodamine B and biacetyl was studied under conditions in which only the sensitizer absorbs. The reaction products resulting from ammonia aquation and Ru(II) to Ru(III) oxidation are the same for direct and sensitized photolysis. The energy transfer rate constant, calculated from the fluorescence quenching of rhodamine B, is similar to that estimated from the limiting quantum yield of the photosensitized photoaquation of the complex. Both reactions originate from a common reactive low-lying ligand-field (LF) state, which is also responsible for the direct photolysis reactions. This state, which leads directly to photoaquation, seems to have a certain charge transfer to solvent (CTTS) character, which is responsible for the photo-oxidation products. Sensitization is effective with rhodamine B (17 450 cm(-1)) and biacetyl (19 000 cm(-1)), whereas no reaction is observed with neutral red (16 900 cm(-1)). These results show that the excited state responsible for the photochemical reactions lies in the energy range between 16 900 cm(-1) and 17 700 cm(-1) and possesses spin-orbit character.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Toxic baits are the most used control method for leaf-cutting ants due to their high effectiveness and because they are considered the safest for humans. Taking into account that the importance of leaf-cutting ants as pests, knowing the process by which dispersal and worker contamination is achieved becomes essential to understand several aspects about the functioning of a bait-borne AI (active ingredient) used in toxic baits. It has been established that an effective toxic bait should have a delayed- action AI, but its dispersion among the different sizes of workers is unknown. Workers of different sizes are involved in quite different tasks such foraging, cultivation of symbiotic macrofungus or control of deleterious microfungi. Therefore, we prepared a toxic bait containing the delayed-action AI sulfluramid and a dye (Rhodamine B) as an AI tracer in order to study dispersal and contamination in colonies, evaluated at different periods and in relation to different workers' sizes. Both field and laboratory colonies were evaluated. The great level of contamination, about 50% at 24 hours, in all sizes of workers demonstrates that worker contact with toxic bait is intense within this period. The distribution in field and laboratory colonies was similar. This contamination pattern is probably enough to cause the colony to die because of contamination of smaller workers, leading to the loss of control of the aggressive microfungi, which can quickly overgrow the symbiotic fungus culture. The dispersal dynamics of AI in leaf-cutting ant workers is important for investigations on the mode of action of this insecticide in the colony, and as a reference in future studies, such as those attempting to reduce the concentration of AIs in baits to reduce their environmental impact, or for facilitation of new AI screening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to detect occlusal caries. Methods. The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site. Results. The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy for the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly. Conclusions. For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure. Clinical Implications. When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)