251 resultados para Landfill biogas

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present work showed the results of the biogas surface emissions from two large landfills. The study methodology consisted on escaping biogas analysis on the landfill surface, through the flux box and laboratory analysis. The total average emission of Bandeirantes Landfill was 0.00126 m3.CH4.m-2.h-1 and in Caieiras Landfill it was of 0.01222 m3.CH4.m-2.h-1. Those results were used to determinate the biogas escape both landfills. The total escape in Bandeirantes Landfill biogas accounted for 16% and in Caieiras, 35%. The conclusions demonstrated that there is a significant loss of biogas through the surface in both landfills, thus compromising the efficiency of the capture for using biogas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The landfill biogas can be an alternative energetic resource as a fuel to electrical energy generators, although, there are not too many techniques to prospect the gas. Usually, landfills receive home waste, which in most are constituted by organic matter whose degradation by anaerobic activity produces the biogas. Geophysics is an important tool in environmental studies and the electrorresistivity, an important method employed in contaminated areas by slurry or necroslurry, including a monitoring for each contaminator flow. The electrorresistivity has not too much application in finding biogas. For this work, two biogas drains in Rio Claro-SP landfill were selected: one whose waste disposition correspond to the initial activities in the landfill and another drain whose disposition started more recently. The result consists in a higher biogas production if compared to the biogas from the older drain. The present paper consists in a monitoring along one year, with dates collection in each fifteen days. These dates were tabled in Excel 2010 program and graphics of resistivity x depth were generated. Hereafter, most variable resistivity values depth were chosen, to further graphics pluviosity x resistivity generation in Grapher 8 program and the biogas output (m³/h) in monitoring period. The use of pluviosity parameter can be justified by its influence above resistivity. The results show that there is a horizon with possibly biogas accumulation. Lastly, the method was effective, although, for any application of geophysical methods, the knowledge about its limitations is necessary; in this case the influence of pluviosity and also that the measurements were made in one single point, it will not show any side variation

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The biogas originated from anaerobic degradation of organic matter in landfills consists basically in CH4, CO2, and H2O. The landfills represent an important depository of organic matter with high energetic potential in Brazil, although with inexpressive use in the present. The estimation of production of the productive rate of biogas represents one of the major difficulties of technical order to the planning of capture system for rational consumption of this resource. The applied geophysics consists in a set of methods and techniques with wide use in environmental and hydrogeological studies. The DC resistivity method is largely applied in environmental diagnosis of the contamination in soil and groundwater, due to the contrast of electrical properties frequent between contaminated areas and the natural environment. This paper aims to evaluate eventual relationships between biogas flows quantified in drains located in the landfill, with characteristic patterns of electrical resistivity in depth. The drain of higher flow (117 m3 /h) in depth was characterized for values between 8000 Ω⋅m and 100.000 Ω⋅m, in contrast with values below 2000 Ω⋅m, which characterize in subsurface the drain with less flow (37 m3 /h), besides intermediary flow and electrical resistivity values, attributed to the predominance of areas with accumulation or generation of biogas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Urban solid residues are constituted of food remaining, grass leaves, fruit peelings, paper, cardboard, rubber, plastic, etc. The organic fraction formed represents about 50% during the decomposition yields biogas and leachate, which are sources of pollution. Residue samples were collected from the landfill in different and cells from several ages and the corresponding leachate, both after treatments, were submitted to thermal analysis. Kinetic parameters were determined using Flynn-Wall-Ozawa method. The linear relation between the two kinetic parameters (ln A and E) was verified for organic residue urban's samples, but not for leachate's sample. The occurred difference can be attributed to the constituents present in leachate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com a finalidade de se analisar quali/quantitativamente o biogás produzido por 6 tipos de substratos, efetuou-se a presente pesquisa no DER/FCAV/UNESP- SP, Brasil. Os substratos utilizados na digestão anaeróbia foram caracterizados como: 1- Esterco de aves de postura (EAP); 2- Esterco de aves de postura triturado (EAPT); 3- Esterco de aves de corte com cama de maravalha (EACM); 4- Esterco de aves de corte com cama de maravalha triturado (EACMT); 5- Esterco de aves de corte com cama de casca de amendoim (EACA), e 6- Esterco de aves de corte com cama de casca de amendoim triturado (EACAT). Dos resultados obtidos, concluiu-se que, em relação à produção acumulada de biogás, o substrato EAPT foi superior aos demais, enquanto EACM apresentou produção acumulada inferior. em geral, os substratos triturados apresentaram maior quantidade de biogás acumulado em relação aos não triturados, exceto o EACAT, com 20,9 m³ inferior ao EACA. O período de produção máxima de biogás teve início entre 45 e 60 dias, começando a decair a partir dos 120 dias. Aos 57 dias após o enchimento dos biodigestores, o gás produzido possuía teores de CH4 superiores a 53%, e a partir dos 99 dias, todos produziram biogás com teores de CH4 superiores a 70%. Os substratos EAP e EAPT apresentaram maiores concentrações de metano no biogás.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper is proposed the use of biogas generated in the Wastewater Treatment Plant of a Dairy industry. The objective is to apply a thermoeconomic analysis to the supplementary cold water production of an absorption refrigeration system (NH3 + H2O) by the burning of such gas. The exergoeconomic analysis is carried out to allow a comparison between an absorption refrigeration system and of an equivalent compression refrigeration system that uses NH3 as work fluid. The proposed exergoeconomic model uses functional diagrams and allows one to obtain the exergetic incremental functions for each component individually and for the system as a whole. The model minimizes the exergetic manufacturing cost (EMC) which represents the cost of supplementary cold water production at 1degreesC (exergetic base) needed for this dairy's cold storage. As a conclusion, the absorption refrigeration system is better than compression refrigeration system, when the biogas cost is not considered. 2004 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article compares the efficiency of induced polarization (IP) and resistivity in characterizing a contamination plume due to landfill leakage in a typical tropical environment. The resistivity survey revealed denser electrical current flow that induced lower resistivity values due to the high ionic content. The increased ionic concentration diminished the distance of the ionic charges close to the membrane, causing a decrease in the IP phenomena. In addition, the self-potential (SP) method was used to characterize the preferential flow direction of the area. The SP method proved to be effective at determining the flow direction; it is also fast and economical. In this study, the resistivity results were better correlated with the presence of contamination (lower resistivity) than the IP (lower chargeability) data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The organic fraction of urban solid residues disposed of in sanitary landfills during the decomposition yields biogas and leachate, which are sources of pollution. Leachate is a resultant liquid from the decomposition of substances contained in solid residues and it contains in its composition organic and inorganic substances. Literature shows an increase in the use of thermoanalytical techniques to study the samples with environmental interest, this way thermogravimetry is used in this research. Thermogravimetric studies (TG curves) carried out on leachate and residues shows similarities in the thermal behavior, although presenting complex composition. Residue samples were collected from landfills, composting plants, sewage treatment stations, leachate, which after treatment, were submitted for thermal analysis. Kinetic parameters were determined using the Flynn-Wall-Ozawa method. In this case they show little divergence between the kinetic parameter that can be attributed to different decomposition reaction and presence of organic compounds in different phases of the decomposition with structures modified during degradation process and also due to experimental conditions of analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leachate samples from a sanitary landfill of Araraquara city and composting usine of Vila Leopoldina, São Paulo, Brazil were lyophilized to remove the water content. TG/DTG curves at different heating rates were recorded. The second step of the thermal decomposition of leachate from the Araraquara landfill (CB1), from the composting usine from Vila Leopoldina (CB2) from the organic phase extracted (FO) and aqueous phase (FA) were all kinetically evaluated using the non-isothermal method.By Flynn-Wall isoconversional method the following values were obtained: E=234 +/- 3.65 kJ mol(-1) and logA=29.7 +/- 0.58 min(-1) for CB1; E=129 +/- 1.66 kJ mol(-1) and logA=11.8 +/- 0.10 min(-1) for CB2; E=51.6 +/- 1.35 kJ mol(-1) and logA=6.09 +/- 0.09 min(-1) for FO and E=76.91 +/- 6.33 kJ mol(-1) and logA=8.88 +/- 0.7 min(-1) for FA with 95% confidence level. Applying the procedures of Malek and Koga, SB kinetic model (Sestak-Berggren) is the most appropriate to describe the decomposition of CB1, CB2, FO and FA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A biophysical understanding of the MSW-to-energy facility located at the Sao Joao landfill in São Paulo is performed using emergy synthesis. The implementation of a plan for environmental compensation in fulfillment of State's requirements was also assessed. Emergy based indices are calculated to assess the environmental pressure and sustainability status of the biogas project. The study was conducted by combining the study of emergy indicators and the net emergy yield ratio to determine long-term sustainability and measure global environmental stress. The Emergy investment to the use of biogas is relatively low and profitable. The implementation of the project for environmental compensation does not change the Emergy investment significantly, but the energy recovery is high. The conclusions justify the effort invested in developing MSW-to-energy plants and are applicable for policy makers in a highly sensitive sector to achieve sustainability goals - recovery of energy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current technological development made by the absorption refrigeration system is an economic and ambient alternative in comparison to the vapor cycle, possessing an advantage that uses thermal energy that is less noble. Chillers of absorption are used widely in the air conditioned industries, because they can be set in motion through hot water vapors that burn natural gas, solar energy, biomasses amongst others instead of electricity. These systems allow it to reduce the tips of electric demand and balance the rocking of energy demand. This work has had a main objective to simulate a absorption refrigeration cycle with lithium-water bromide solution using biogas of sanitary landfill, and mixtures of this with natural gas. These results shown to the energy viability of the system burning biogas and its mixtures with natural gas in the generator, when compared with equipments that uses traditional fuels (natural gas, oil diesel, amongst others), for operation the commercial chillers with 15 kW of the refrigeration capacity and temperature of the water in the entrance of 14°C and the exit of 7°C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)