75 resultados para LED lighting
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
With the imposition of the suspension of production and subsequent banning of incandescent light bulbs will be necessary to replace it by other more energy-efficient. Although the main alternative is the compact fluorescent lamp, the environmental impact caused by it due to incorrect disposal and the amount of harmonics included in the network resulting in losses related to the quality of electric power system makes them sought new alternatives for lighting systems that are efficient and have low environmental impact. In this context, the LED (Lighting Emitting Diode), based on solid-state components, is presented as an option for new projects and replacement of existing lighting. In this work we studied aspects of energy, environmental and economic impacts of a possible replacement of conventional lighting systems for new technology. From laboratory tests and surveys of the costs of different types of lamps used for residential lighting, we performed a comparative analysis considering energy and economic aspects which showed that the LED technology, but has a high initial investment, it is best when power quality and environmental preservation are relevant factors in decision making for the choice of technology to be used in the lighting system
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of our investigation is to compare the intrapulpal temperature changes following blue LED system and halogen lamp irradiation at the enamel surface of permanent teeth. The fixation of brackets using composite resin is more comfortable and faster when using a photo-curable composite. Several light sources can be used: halogens, arc plasma, lasers, and recently blue LED systems. An important aspect to be observed during such a procedures is the temperature change. In this study, we have used nine human extracted permanent teeth: three central incisors, three lateral incisors, and three canines. Teeth were exposed to two light sources: blue LED system (preliminary commercial model LEC 470-II) and halogen lamp (conventional photo-cure equipment). The surface of teeth was exposed for 20, 40, and 60 sec at the buccal and lingual enamel surface with an angle of 45 degrees. Temperature values measured by a thermistor placed at pulpar chamber were read in time intervals of 1 sec. We obtained plots showing the temperature evolution as a function of time for each experiment. There is a correlation between heating quantity and exposition time of light source: with increasing exposition time, heating increases into the pulpal chamber. The halogen lamp showed higher heating than the LED system, which showed a shorter time of cooling than halogen lamp. The blue LED system seems like the indicated light source for photo-cure of composite resin during the bonding of brackets. The fixation of brackets using composite resin is more comfortable and faster when using a photo-curable composite. Blue LED equipment did not heat during its use. This could permit a shorter clinical time of operation and better performance. © Mary Ann Liebert, Inc.
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
This work deals with a red phosphor. Y3BO6:Eu3+, and its corresponding poly(N-vinylpyrrolidone) (PVP)/Y3BO6:Eu3+ luminescent composite film suitable for applications in the next generation of Hg-free lamps based on near ultraviolet (UV) light emitting diodes (LEDs). Well crystallized samples of Y3BO6 powders with the Eu3+ content up to 20 mol% were prepared by the Pechini method. After structural, morphological and optical characterization, the best doping rate of Eu3+ in the matrix was determined to be 15 mol%. This optimal powder, which is highly friable, was easily ground into fine particles and homogeneously dispersed into a PVP polymer solution to give rise to a polymer phosphor composite. Structural and optical features of the composite film have been studied and compared to those of a pristine PVP film and Y3BO6:Eu3+ powder. All the characterization (XRD, SAXS, luminescence...) proved that the red phosphor particles are well incorporated into the polymer composite film which exhibited the characteristic red emission of Eu3+ under UV light excitation. Furthermore, photostability of the polymer/phosphor composite film under UV-LED irradiation was evaluated from exposure to accelerated artificial photoageing at wavelengths above 300 nm.
Resumo:
This Graduate Work aims to exhibit the analyze of the applicability of LED technology in a real outdoor lighting situation, and this project’s illumination solution is compared with the initial proposal, the sodium vapor lamps. What is studied is an outdoor area, like the roads and parking lots of a plant. A light planning software is used for this comparison, and the results are displayed instantly, allowing rapid analysis of the project through a simulation. The medium illuminance is the same in both solutions for this case study and minimum rates set as standard were observed then the analysis are appropriate in this project. Various aspects are considered in order to obtain a comprehensive analysis of this project, such as economic, environmental and quality of lighting. LED technology in outdoor lighting is presented in its infancy, but promising. Solid state lamps show great advantages when compared with other technologies, such as discharge lamps, however there are some disadvantages tied to new products that are expected to be overcome with technological development and increased production
Resumo:
This work presents the development of the External Lighting Plan UNESP in the Itapeva Campus based LED and Solar Energy. Firstly it was made a collection of data from measurements of the local transit through the Google Earth 6 software and divide the local in sectors, and then perform an analysis of characteristics and age of the site. With these data it was possible to determine the average luminance the place, in30 lux. After these procedures was possible to determine the type of sets that would perform the role of bridge lighting the kit chosen was the 20/20 Sun LED manufacturer, since it contains the luminaire with the solar panel to the pole. Therefore we determined the number of poles for each sector, whichwas72in total and. After the determination of the location of each point lighting
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was the evaluation of the effectiveness of photodynamic therapy on the decontamination of artificially induced carious bovine dentin, using Photoge(R) as the photosensitizer agent and an LED device as a light source. Dentin samples obtained from bovine incisors were immersed in sterile broth supplemented by Lactobacillus acidophillus 10(8) colony formation units (CFU) and Streptococcus mutans 10 8 CFU. Different concentrations of photosensitizer, PA = 1 mg/ml, PB = 2 mg/ml, and PC = 3 mg/ml, and two fluences, D = 24 J/cm(2) and D = 48 J/cm(2), were investigated. After CFU counting per milligram of carious dentin and statistical analysis, we observed that the photodynamic therapy (PDT) parameters used were effective for bacterial reduction in the in vitro model under study. The best result was achieved with the application of Photoge(R) at 2 mg/ml and photoactivated under 24 J/cm(2) showing a survival factor of 0.14. At higher photosensitizer concentrations, a higher dark toxicity was observed. We propose a simple mathematical expression for the determination of PDT parameters of photosensitizer concentration and light fluence for different survival factor values. Since LED devices are simpler and cheaper compared to laser systems, it would be interesting to verify their efficacy as a light source in photodynamic therapy for the decontamination of carious dentin.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The objective was to investigate whether the productivity of rabbit does can be improved, when natural photoperiod is decreasing, by adopting a supplemental lighting program. Three experiments were conducted involving two groups: control, submitted to the natural decreasing photoperiod, and supplemented with a lighting program which provided 14 h light/24 h beginning at 10 weeks of age. In the first experiment, 20 nulliparous does, 10 from each group, were euthanized 8 h after being presented to a buck; the overall number of follicles, whose diameter exceeded I mm, was determined macroscopically. The right ovaries were collected, histologically analyzed, and electronically measured. In the second experiment, 30 nulliparous does, 15 from each group, were presented to a buck (day 1). Receptive does were euthanized on day 8 to evaluate embryonic survival (number of normal embryos/ovulation rate). In the third experiment, 48 nulliparous does, 24 from each group, were followed from the first presentation to the buck until the weaning of the first litter. The effect of treatment on reproductive and body weight traits of does, and litter performance traits, at birth and weaning, was evaluated. The average number of follicles whose diameter exceeded 1 mm was higher in the treatment group (12.05 +/- 1.07 vs. 8.63 +/- 1.00, P=0.03 7). Receptive does of the treatment group had heavier ovaries relative to those of the control group (790 +/- 59 vs. 470 +/- 64 mg, P=0.004), whereas no treatment difference regarding this trait was found for non-receptive ones. Treatment had a favorable effect on pregnancy rate of total exposed and of receptive does (80.0% vs. 33.3%, P=0.01, and 92.3% vs. 50.0%, P=0.02, respectively). The number of underdeveloped embryos was lower (0.067 +/- 0.380 vs. 2.500 +/- 0.455, P=0.004), embryonic survival up to day 8, and uterus weight was higher in the treatment group (0.839 +/- 0.075 vs. 0.534 +/- 0.087, P=0.033 and 13.83 +/- 0.72 vs. 10.99 +/- 0.84, P=0.037, respectively). Number of presentations tended to be lower (1.32 +/- 0.17 vs. 1.75 +/- 0.16, P=0.077) and adjusted litter size in the first reproductive cycle tended to be higher (7.09 +/- 0.89 vs. 5.22 +/- 0.68, P=0.091) in the treatment group relative to the control.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The purpose of this study was to evaluate the polymerization effectiveness of a composite resin (Z-250) utilizing microhardness testing. In total, 80 samples with thicknesses of 2 and 4 mm were made, which were photoactivated by a conventional halogen light-curing unit, and light-curing units based on LED. The samples were stored in water distilled for 24 h at 37C. The Vickers microhardness was performed by the MMT-3 microhardness tester. The microhardness means obtained were as follows: G1, 72.88; G2, 69.35; G3, 67.66; G4, 69.71; G5, 70.95; G6, 75.19; G7, 72.96; and G8, 71.62. The data were submitted to an analysis of variance (ANOVA's test), adopting a significance level of 5%. The results showed that, in general, there were no statistical differences between the halogen and LED light-curing units used with the same parameters.
Resumo:
The Epiphany (TM) Sealer is a new dual-curing resin-based sealer and has been introduced as an alternative to gutta-percha and traditional root canal sealers. The canal filling is claimed to create a seal with the dentinal tubules within the root canal system producing a 'monoblock' effect between the sealer and dentinal tubules. Therefore, considering the possibility to incorporate the others adhesive systems, it is important to study the bond strength of the resulting cement. Forty-eight root mandibular canines were sectioned 8-mm below CEJ. The dentine discs were prepared using a tapered diamond bur and irrigated with 1% NaOCl and 17% EDTA. Previous the application Epiphany (TM) Sealer, the Epiphany (TM) Primer, AdheSE, and One Up Bond F were applied to the root canal walls. The LED and QTH (Quartz Tungsten Halogen) were used to photo-activation during 45 s with power density of 400 and 720 mW/cm(2), respectively. The specimens were performed on a universal testing machine at a cross-head speed of 1 mm/min until bond failure occurred. The force was recorded and the debonding values were used to calculate Push-out bond strength. The analysis of variance (ANOVA) and Tukey's post-hoc tests showed significant statistical differences (P < 0.05) to Epiphany (TM) Sealer/Epiphany (TM) Primer/QTH and EpiphanyTM Sealer/AdheSE/QTH, which had the highest mean values of bond strength. The efficiency of resin-based filling materials are dependent the type of light curing unit used including the power density, the polymerization characteristics of these resin-based filling materials, depending on the primer/adhesive used.