98 resultados para LAMP

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work has as objective to develop an interesting research line in the Optical Instrumentation area, that is to associate the Optical Design to the Ophthalmology area. The purpose of it is handling the optical design techniques to design a widely used ophthalmologic instrument called slit lamp. The optical and mechanical design of the slit lamp prototype was carefully projected in order to improve the best quality image, the comfort of the patient and the user, the simplicity of handling, the facility of production the availability of optical and mechanical components in the national market and the low cost of production. The main goal of this work was to realize a project using totally national technology, cheapening the cost and forming the optimum image required for the slit lamp optical system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An electronic ballast for multiple tubular fluorescent lamp systems is presented. The proposed structure has a high value for the power factor, a dimming capability, and soft switching of the semiconductor devices operated at high frequencies. A zero-current switching pulse width modulated SEPIC converter is used as the rectifying stage and it is controlled using the instantaneous average input current technique. The inverting stage consists of classical resonant half-bridge converter with series-resonant parallel-loaded filters. The dimming control technique is based on varying the switching frequency and monitoring the phase shift of the current drained by the filters and lamps in order to establish a closed loop control. Experimental results are presented that validate the theoretical analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new methodology for the determination of fluorescent lamp models based on equivalent resistances. One important feature of the proposed methodology is concerned with the inclusion of the filaments into the model, considering the effects of dimming operation on the equivalent resistances. The classical Series-Resonant Parallel-Loaded Half-Bridge inverter is used as the power stage of the ballast. Moreover, the variation of the inverter's switching frequency is the dimming technique assumed for the analyses. Results obtained with a F32T8 lamp indicate that the accuracy of the model is very satisfactory. Thus, the lamp models obtained with the proposed methodology have the potential to serve as an important tool for ballast designers, considering the necessity for evaluating the lamp/ballast compatibility, according to issues concerned to the operating conditions of the electrodes' filaments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an improved design methodology for determining the parameters used in the classical Series-Parallel Loaded Resonant (SPLR) filter employed in the switching frequency controlled dimmable electronic ballasts. According to the analysis developed in this paper, it is possible to evaluate some characteristics of the resonant filter during the dimming process, such as: range of switching frequency, phase shift and rms value of the current drained by the resonant filter + fluorescent lamp set.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an improved design methodology for the determination of the parameters used in the classical series-resonant parallel-loaded (SRPL) filter employed in the switching frequency controlled dimmable electronic ballasts. According to the analysis developed in this paper, it is possible to evaluate some important characteristics of the resonant filter during the dimming operation, such as: range of switching frequency, phase shift, and rms value of the current drained by the resonant filter + fluorescent lamp set. Experimental results are presented in order to validate the analyses developed in this paper. © 2005 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study sought to assess the pulp chamber temperature in different groups of human teeth that had been bleached using hydrogen peroxide gel activated with halogen lamps or hybrid LED/laser appliances. Four groups of ten teeth (maxillary central incisors, mandibular incisors, mandibular canines, and maxillary canines) were used. A digital thermometer with a K-type thermocouple was placed inside pulp chambers that had been filled with thermal paste. A 35% hydrogen peroxide-based red bleaching gel was applied to all teeth and photocured for a total of three minutes and 20 seconds (five activations of 40 seconds each), using light from an LED/laser device and a halogen lamp. The temperatures were gauged every 40 seconds and the data were analyzed by three-way ANOVA, followed by Tukey's test. Regardless of the light source, statistically significant differences were observed between the groups of teeth. The mean temperature values (±SD) were highest for maxillary central incisors and lowest for mandibular canines. The halogen lamp appliance produced more pulp chamber heating than the LED/laser appliance. The increase in irradiation time led to a significant increase in temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a new static model for tubular fluorescent lamps (T12 bulb) operated at high frequencies. The main goal of this paper is to investigate the effects of ambient temperature and nominal switching frequency of operation in the static characteristics of tubular fluorescent lamps. The methodology for obtaining the model is based on several two-dimensional mathematical regressions, used to provide the behavior of the fluorescent lamp according to different independent variables, namely: power processed through the lamp and ambient temperature. In addition, the proposed model can be easily converted to a lamp equivalent resistance model, which can be useful for ballast designers. Finally, the curves obtained using the new model are compared to the correspondent experimental data, in order to verify the accuracy of the proposed methodology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a new methodology for the adjustment of the preheating process and steady-state operation of electronic ballasts intended for hot-cathode fluorescent lamps. The classical series-resonant parallel-loaded half-bridge inverter is the power stage analyzed in this paper. In addition, the preheating process is based on the imposition of a constant rms current through the electrodes, in order to provide a proper value of the R-h/R-c ratio before the lamp start. According to the proposed methodology, it is possible to set suitable operating points for, the electronic ballast, considering optimal conditions for the lamps electrodes. Therefore, the proposed methodology for setting the preheating and steady-state operation is a complete platform to the design of electronic ballasts for hot-cathode fluorescent lamps.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: Avaliar as mudanças de curvatura corneana ocorridas após a exérese do pterígio (Pt). Métodos: Foi realizado estudo prospectivo em 49 olhos com Pt primário avaliando-se idade, sexo, tamanho [grau (G) I, GII, GIII e GIV] e a morfologia da lesão (atrófica ou carnosa) à biomicroscopia. Todos os pacientes foram submetidos ao exame de videoceratoscopia computadorizada e ceratometria no pré-operatório (pré-op), e no 30º e 60º dias após a cirurgia. Os dados foram submetidos à análise estatística. Resultados: 63% dos indivíduos avaliados eram do sexo masculino e 80% tinham mais de 41 anos. Houve predomínio dos Pt atróficos (77%), GII e GIII (39% e 28%, respectivamente). Observou-se manutenção do astigmatismo (Astg) presente no pré-operatório no 2º mês pós-operatório (PO), principalmente nos portadores de Pt GI e GII. A variação no valor de K do 1º mês para o 2º mês de PO foi pequena. As variações observadas estiveram mais relacionadas com o tamanho do pterígio, do que com a idade do paciente, ou com as suas características morfológicas. Conclusões: A avaliação ceratométrica e topográfica da córnea em portadores de pterígio no pré e no pós-operatório mostrou que os Pt menores (GI e GII) estão associados com graus menores de astigmatismo e no pós-operatório a córnea sofre menos mudanças que nos GIII e GIV. Após 2 meses da cirurgia, o padrão da curvatura corneana é semelhante ao do pré-operatório, na maioria dos pacientes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a condição ocular em população de trabalhadores de uma indústria metalúrgica paulista. MÉTODOS: Amostra de 2516 funcionários de uma fábrica na cidade de São Paulo foi submetida a uma avaliação oftalmológica como exame ocupacional periódico. Foi aplicado um questionário e realizado o exame de acuidade visual (Snellen) e teste de Ishihara. Os funcionários com acuidade visual menor que 0,7 ou com diferenças maior que duas linhas ou que apresentassem alguma queixa ocular, passaram por avaliação complementar (biomicroscopia, refração, tonometria e fundo de olho). Prescreveu-se óculos conforme indicação. RESULTADOS: Houve predomínio do sexo masculino (62,5%) e faixa etária de 20 a 29 anos (41%). A maioria não apresentava antecedentes oculares (97,6%) ou sistêmicos (96,6%).A acuidade visual estava acima de 0,7 em 95,5% dos olhos e 84% não utilizavam correção. O diagnóstico final foi exame normal em 55% dos casos, presbiopia em 13.6%, astigmatismo miópico em 10% e hipermetrópico em 7,7% dos indivíduos. Baixa visão foi encontrada em 2,4%, cegueira unilateral em 0,4%, não havendo casos de cegueira ou de deficiência visual entre os trabalhadores. As principais causas de baixa visão foram erros refrativos e ambliopia. CONCLUSÃO: A maioria dos funcionários da indústria pesquisada apresentava exame oftalmológico normal e nenhum deles apresentava cegueira bilateral.