134 resultados para Involuntary sterilization.

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cold atmospheric plasma treatment of microorganisms and living tissues has become a popular topic in modern plasma physics and in medical science. The plasma is capable of bacterial inactivation and noninflammatory tissue modification, which makes it an attractive tool for treatment of skin diseases, open injuries and dental caries. Because of their enhanced plasma chemistry, Dielectric Barrier Discharges (DBDs) have been widely investigated for some emerging applications such as biological and chemical decontamination of media at ambient conditions. Despite the high breakdown voltage in air at atmospheric pressure, the average current of DBD discharges is low. Therefore, a DBD can be applied in direct contact with biological objects without causing any damage. In this work a 60 Hz DBD reactor, which generates cold atmospheric plasma inside Petri dishes with bacterial culture, is investigated. Samples of Staphylococcus aureus, a Gram-positive bacterium and Escherichia coil a Gram-negative bacterium were selected for this study. The bacterial suspensions were evenly spread on agar media planted in Petri dishes. The reactor electrodes were placed outside the Petri dish, thus eliminating the risk of samples microbial contamination. The covered Petri dish with agar medium in it serves as dielectric barrier during the treatment. The plasma processing was conducted at same discharge power (similar to 1.0 W) with different exposure time. Sterilization of E. coil and S. aureus was achieved for less than 20 min. Plasma induced structural damages of bacteria were investigated by Scanning Electron Microscopy. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Acrylic resin denture teeth soften upon immersion in water, and the heating generated during microwave sterilization may enhance this process.Purpose. Six brands of acrylic resin denture teeth were investigated with respect to the effect of microwave sterilization and water immersion on Vickers hardness (VHN).Material and Methods. The acrylic resin denture teeth (Dentron [D], Vipi Dent Plus [V], Postaris [P], Biolux [B], Trilux [T], and Artiplus [A]) were embedded in heat-polymerized acrylic resin within polyvinylchloride tubes. For each brand, the occlusal surfaces of 32 identical acrylic resin denture posterior teeth were ground flat with 1500-grit silicon carbide paper and polished on a wet polishing wheel with a slurry of tin oxide. Hardness tests were performed after polishing (control group, C) after polishing followed by 2 cycles of microwave sterilization at 650 W for 6 minutes (MwS group), after polishing followed by 90-day immersion in water (90-day Wim group), and after polishing followed by 90-day storage in water and 2 cycles of microwave sterilization (90-day Wim + MwS group). For each specimen, 8 hardness measurements were made and the mean was calculated. Data were analyzed with a 2-way analysis of variance followed by the Bonferroni procedure to determine any significance between pairs of mean values (alpha=.01).Results: Mircrowave sterilization of specimens significantly decreased (P <.001) the hardness of the acrylic resin denture tooth specimens P (17.8 to 16.6 VHN, V (18.3 to 15.8 VHN), T (17.4 to 15.3 VHN), B (16.8 to 15.7 VHN), and A (17.3 to 15.7 VHN). For all acrylic resin denture teeth, no significant differences in hardness were found between the groups Mws, 90-day Wim, and 90-day Wim + MwS, with the exception of the 90-day Wim + MwS tooth A specimens (14.4 VHN), which demonstrated significant lower mean values (P <.001) than the 90-day Wim (15.8 VHN) and MwS (15.7 VHN) specimens.Conclusions. For specimens immersed in water for 90 days, 2 cycles of microwave sterilization had no effect on the hardness of most of the acrylic resin denture teeth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effectiveness of microwave irradiation sterilization on hard chairside reline resins. Materials and Methods: Specimens of three reline resins (Kooliner, Tokuso Rebase, and Ufi Gel Hard) were fabricated and subjected to ethylene oxide sterilization. The specimens were then individually inoculated (107 cfu/mL) with Tryptic Soy Broth media containing one of the tested microorganisms (C albicans, S aureus, B subtilis, and P aeruginosa). After 48 hours at 37°C, the samples were vortexed for 1 minute and allowed to stand for 9 minutes, followed by a short vortex to resuspend any organisms present. After inoculation, 40 specimens of each material were immersed in 200 mL of water and subjected to microwave irradiation at 650 W for 6 minutes. Forty non-irradiated specimens were used as positive controls. Replicate specimens (25 μL) of suspension were plated at dilutions of 10-3 to 10-6 on plates of selective media appropriate for each organism. All plates were incubated at 37°C for 48 hours. After incubation, colonies were counted, and the data were statistically analyzed by the Kruskal-Wallis test. Twelve specimens of each material were prepared for SEM. Results: All immersed specimens showed consistent sterilization of all the individual organisms after microwave irradiation. SEM examination indicated an alteration in cell morphology after microwave irradiation. Conclusion: Microwave sterilization for 6 minutes at 650 W proved to be effective for the sterilization of hard chairside reline resins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tillandsia gardneri is a bromeliad with ornamental value and a wide geographical distribution over Brazil. However, due to habitat loss and illegal overcollection in the wild it is included as a vulnerable species in the official list of endangered plants of the State of Rio Grande do Sul, Brazil. The development of a protocol for T. gardneri seed propagation in vitro may be useful for reintroducing plants in their natural habitats, and for germplasm conservation. A difficult problem encountered during the establishment of an in vitro culture is explants disinfection, especially when working with endangered species, from which explant availability is restricted. Thus, the establishment of a sterilization protocol is crucial for the initiation and success of a micropropagation system for T. gardneri. The objective of this study was to evaluate the effect of sodium hypochlorite concentration and exposure time in seed and seedling surface disinfection, tissue sensitivity and development. Sodium hypochlorite solutions (10 or 20%/5, 10 or 15 min; 25%/5 or 10 min; and 50%/5 min) were effective in eliminating seed superficial contaminants. There was no significant difference among the effective sterilization treatments in relation to seed germination (%), and seedling length and number of leaves, after 120 days in vitro. Also, no damage to seed and seedling tissues were observed. Surface sterilization of seedlings, for initiation of an in vitro culture, required higher concentrations of sodium hypochlorite (25%/15 min; 20 or 50%/5, 10 or 15 min; and 40%/5 and 10 min) for controlling fungal and yeast contamination, compared to seed sterilization. No significant differences among these treatments were found in relation to seedling length and number of leaves, after 60 days in vitro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose:The aim of this study was to evaluate deformation, roughness, and mass loss of stainless steel, diamond-like carbon (DLC)-coated and zirconia drills after multiple osteotomies with sterilization procedures.Materials and Methods:Drilling procedures were performed using stainless steel (G1), DLC-coated (G2), and zirconia (G3) drills. All groups were divided in subgroups 1, 2, 3, 4, and 5, corresponded to drills used 0, 10, 20, 30, and 40 times, respectively.Results:No significant differences in mass and roughness were detected among all groups and subgroups. In SEM images, all groups revealed signs of wear while coating delamination was detected in G2. Drills from G1 displayed more irregular surface, whereas cutting edges were more regular in G3.Conclusion:Zirconia drills presented more regular surfaces whereas stainless steel drills revealed more severe signs of wear. Further studies must be performed to evaluate the putative influence of these findings in heat generation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Foram realizados estudos empregando-se analgésicos por via epidural e subcutânea em cadelas de diferentes raças e idades, submetidas à castração mediante celiotomia. Vinte animais foram tranquilizados e anestesiados com tiletamina-zolazepam, e aleatoriamente distribuídos em quatro grupos (n=5), de acordo com o fármaco e a via de administração. Os do grupo morfina (GM) foram submetidos à anestesia epidural no espaço lombossacro, com morfina (0,1mg/kg) associada ao cloreto de sódio a 0,9%. Aos do grupo xilazina (GX), foram administrados xilazina (0,2mg/kg) e cloreto de sódio a 0,9%. Os do grupo meloxicam (GME) receberam 0,2mg/kg do anti-inflamatório meloxicam associado ao cloreto de sódio a 0,9%, injetado pela via subcutânea. Os do grupo-controle (CG) receberam apenas cloreto de sódio a 0,9%. O volume final para as injeções epidurais foi padronizado para 0,3mL/kg. A mensuração inicial da concentração de cortisol plasmático, do ritmo cardíaco, da frequência respiratória e os parâmetros comportamentais foram registrados imediatamente antes do procedimento cirúrgico (M1). Registros adicionais foram apresentados às 2, 6, 12 e 24 horas após o procedimento cirúrgico (M2, M3, M4 e M5, respectivamente). As variáveis comportamentais foram avaliadas por meio de sinais clínicos e seus respectivos escores. em GX foram observadas depressão respiratória, bradicardia e concentração de cortisol mais alta do que o registrado no GM. A analgesia obtida pelo meloxicam foi considerada ineficiente. É possível concluir que a morfina, via epidural, promoveu menor incidência de efeitos colaterais e melhor analgesia e bem-estar animal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Avaliou-se o ganho de peso de novilhas mestiças, 1/4 Simental e 3/4 Nelore, empregando-se o método experimental de esterilização, que consiste na introdução intrauterina de esferas inoxidáveis. Foram utilizadas 100 novilhas nulíparas, destinadas ao abate, com idades entre 12 e 24 meses e com média de peso de 275kg. Todos os animais receberam o mesmo manejo alimentar, em sistema de pastejo em Brachiaria brizantha, com água e sal mineral ad libitum, e pesagens a intervalos de 28 dias, obedecido o jejum prévio de 16 horas. Os animais foram distribuídos aleatoriamente em quatro grupos (G) experimentais: G1 - composto por 25 novilhas testemunhas; G2 - por 25 novilhas esterilizadas e aplicação de um modificador orgânico; G3 - por 25 novilhas esterilizadas; e G4 - por 25 novilhas não esterilizadas e aplicação de um modificador orgânico. Foram introduzidas 12 esferas de aço inoxidável, previamente esterilizadas, no útero de cada novilha. Houve maior ganho de peso total e diário entre os animais do G2, 140,50kg e 0,578g/dia vs 108,58kg e 0,447g/dia (G1), 103,73kg e 0,427g/dia (G3), 102,68kg e 0,423g/dia (G4), respectivamente. Esta técnica pode ser recomendada aos criadores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Foi estudada a transferência de calor transiente na agitação linear e intermitente (ALI) de embalagens metálicas contendo simulantes de alimentos, objetivando-se sua aplicação em processos de pasteurização ou esterilização e conseqüentes tratamentos térmicos mais eficientes, homogêneos e com produto de melhor qualidade. Foram utilizados quatro meios fluidos simulantes de alimentos de diferentes viscosidades e massas específicas: três óleos e água. Foram combinados efeitos de cinco tratamentos, sendo: meio simulante (4 níveis), espaço livre (3 níveis), freqüência de agitação (4 níveis), amplitude de agitação (2 níveis) e posição das latas (4 níveis). Os ensaios de aquecimento e resfriamento foram feitos em tanque com água à temperatura de 98 °C e 17-20 °C, respectivamente. Com os dados de penetração de calor em cada experimento, foram calculados os parâmetros de penetração de calor fh, jh, fc e jc. Os resultados foram modelados utilizando-se grupos de números adimensionais e expressos em termos de Nusselt, Prandtl, Reynolds e funções trigonométricas (com medidas de amplitude e freqüência de agitação, espaço livre e dimensões da embalagem). Foram estabelecidas as duas Equações gerais para as fases de aquecimento e resfriamento: Nu = ReA 0,199.Pr 0,288.sen(xa/AM)0,406.cos(xf/FA) 1,039.cos((xf/FA).(EL/H).p) 4,556 Aquecimento Nu = 0,1295.ReA 0,047.Pr 0,193.sen(xa/AM)0,114.cos(xf/FA) 0,641.cos((xf/FA).(EL/H).p) 2,476 Resfriamento O processo de ALI pode ser aplicado em pasteurizadores ou autoclaves estáticas horizontais e verticais, com modificações simples. Concluiu-se que a ALI aumenta significativamente a taxa de transferência de calor, tanto no aquecimento como no resfriamento.