20 resultados para Investigator

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2010 QIAGEN® launched to eight kits of different combinations of STRs, including the Investigator IDplex Kit. This kit allows amplification in one PCR 16 markers. The aim of this study was to evaluate the reproducibility of Investigator IDplex Kit among Latin America laboratories. In the framework of the 'III International Theoretical-Practice Course in Populations Genetic and Biologicals Filiations' in Medellín-Colombia, all participants were invited to evaluate the reproducibility of this kit, they were provided of the necessary materials for the study. The results reported by participating were tabulated for the study the reproducibility. Results and comments were received on the agreed date of 12 of the 22 laboratories registered, one participant submits comments only. Some laboratories reported greater sensitivity Investigator IDplex Kit compared with other kits containing similar markers, also highlight the easy adaptability to existing conditions in laboratories, without involving major changes to its implementation. This paper shows the high reproducibility of Investigator IDplex Kit, a new tool offered by QIAGEN® for all laboratories that perform human identification testing and biological relationship testing using DNA markers. © 2011 Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to determine the effect of maternal hydration with oral isotonic solution and water on the amniotic fluid (AF) index of women with normohydramnios. Women with a normal AF index and gestational age between 33 and 36 weeks without maternal complications were randomized into three groups [isotonic solution (Gatorade (R)), water, control]. The isotonic solution and water groups were instructed to drink 1.5 L of the respective solution and the control group was instructed to drink 200 mL water over a period of 2 to 4 h. AF index was measured before and after hydration by Doppler ultrasonography. The investigator performing the AF index measurement was blind to the subject's group. Ninety-nine women completed the study without any adverse maternal effects. The median increase in AF index after hydration was significantly greater for the isotonic solution and water groups than for the control group. There was no significant difference between the isotonic solution and water groups. Hydration with isotonic solution and water caused a 10-fold (95% CI: 2.09-49.89) and 6-fold (95% CI: 1.16-30.95) increase in the chance of a 20% increase of AF index, respectively. Maternal hydration with isotonic solution or water increased the AF index in women with normohydramnios.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate a prototype pressure stimulus device for use in the cat and to compare with a known thermal threshold device.Eight healthy adult cats weighing between 3.0 and 4.9 kg.Pressure stimulation was given via a plastic bracelet taped around the forearm. Three 2.4 mm diameter ball bearings, in a 10-mm triangle, were advanced against the craniolateral surface of the antebrachium by manual inflation of a modified blood pressure bladder. Pressure in the cuff was recorded at the end point (leg shake and head turn). Thermal threshold was also tested. Stimuli were stopped if they reached 55 degrees C or 450 mmHg without response. After four pressure and thermal threshold baselines, each cat received SC buprenorphine 0.01 mg kg(-1), carprofen 4 mg kg(-1) or saline 0.3 mL in a three period cross-over study with a 1-week interval. The investigator was blinded to the treatment. Measurements were made at 0.25. 0.5, 0.75, 1, 2, 3, 4, 6, 8, and 24 hours after injection. Data were analyzed by using ANOVA.There were no significant changes in thermal or pressure threshold after administration of saline or carprofen, but thermal threshold increased from 60 minutes until 8 hours after administration of buprenorphine (p < 0.05). The maximum increase in threshold from baseline (Delta T-max) was 3.5 +/- 3.1 degrees C at 2 hours. Pressure threshold increased 2 hours after administration of buprenorphine (p < 0.05) when the increase in threshold above baseline (Delta P-max) was 162 +/- 189 mmHg.This pressure device resulted in thresholds that were affected by analgesic treatment in a similar manner but to a lesser degree than the thermal method. Pressure stimulation may be a useful additional method for analgesic studies in cats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este estudo foi realizado objetivando estudar o efeito das práticas de alimentação infantil e de fatores associados sobre a ocorrência de cárie dental. Para isso, determinou-se o ceo-d e o ceo-s em 156 crianças de 18 a 48 meses e foi aplicado às mães um questionário incluindo perguntas sobre a ocupação do pai, nível educacional da mãe, higiene bucal, época de erupção do dente e sobre práticas de alimentação infantil. Os dados obtidos foram analisados através dos testes X2 e Mann-Whitney U. A média do ceo-s foi 3,4 com 40% das crianças livres de cáries, sendo que 36 e 24% tinham um ceo-d maior que 0 e 4, respectivamente. Notou-se que 72% das crianças eram alimentadas ao seio, 17% apenas com mamadeira e 10% pelos dois meios. Das crianças alimentadas apenas com mamadeira 70% apresentaram cárie. A cárie de mamadeira foi observada em 20% das crianças, sendo que 77% destas tinham sido alimentadas por mais de 12 meses. As crianças, cujos pais eram profissionais com terceiro grau de escolaridade, tiveram significativamente menos cárie do que aquelas de pais com nível técnico ou pais operários. A prevalência de cárie na faixa etária estudada foi relativamente alta. As crianças com cárie de mamadeira tenderam a manter seus hábitos de aleitamento por mais de 12 meses, sendo que o uso de mamadeira açucarada estava presente em 100% dos casos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Brazil since October 1996 there have been guidelines for research involving human subjects. Now human subjects know when their treatment is part of research. Deceit is no longer tolerated. But is not enough to say we offer an explanation to the potential subject and we offer a choice before he or she is confronted with an informed consent form. As in all professional activity, scientific investigation needs social controls. In Brazil, the ultimate responsibility of an investigation lies on the investigator, but in every institution where research is carried out there is a Committee for Ethics in Research. All Committees are subordinated to the National Commission of Ethics in Research, which is submitted to the Brazilian Institute of Health. During 2005 around 17,000 protocols involving 700,000 human subjects were revised by 475 Committees distributed all over the country. Approximately 7,000 people are now working in these Committees.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Educação - FFC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciências Odontológicas - FOAR

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Educação - FFC