69 resultados para Intervertebral disk displacement

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To compare the effects of decompressive surgery (DSX), electroacupuncture (EAP), and DSX followed by EAP (DSX + EAP) for the treatment of thoracolumbar intervertebral disk disease (IVDD) in dogs with severe neurologic deficits of > 48 hours' duration.Design Retrospective case series and prospective clinical trial.Animals-40 dogs between 3 and 6 yEAPs old and weighing between 10 and 20 kg (22 and 44 lb) with long-standing (>48 hours) clinical signs of severe neurologic disease attributable to thoracolumbar IVDD.Procedures Thoracolumbar medullar injury was classified on the basis of neurologic signs by use of a scale ranging from 1 (least severe) to 5 (most severe). The DSX dogs (n = 10) were retrospectively selected from those that underwent DSX for the treatment of thoracolumbar IVDD. In addition, 19 dogs received EAP alone and 11 dogs underwent DSX followed by EAP (DSX + EAP). Outcome was considered a clinical success when a dog initially classified as grade 4 or 5 was classified as grade 1 or 2 within 6 months after the end of treatment.Results The proportion of dogs with clinical success was significantly higher for dogs that underwent EAP (15/19) than for dogs that underwent DSX (4/10); the proportion of dogs with clinical success for dogs that underwent DSX + EAP was intermediate (8/11).Conclusions and Clinical Relevance EAP was more effective than DSX for recovery of ambulation and improvement in neurologic deficits in dogs with long-standing severe deficits attributable to thoracolumbar IVDD. (J Am Vet Med Assoc 2010;236:1225-1229)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aims to evaluate safety and effectiveness of the use of orthesis in postoperative degenerative disorders of the cervical spine. Although widely used, there are not defined criteria for the use of cervical collars, and their importance on cervical arthrodesis. A systematic literature review was undertaken and a multicentre controlled clinical trial comprising 32 specialized services, with a total of 257 patients who met the inclusion criteria of the review. Clinical and radiographic outcomes were compared in post surgical patients that used or not rigid cervical collar during 6 to 12 weeks after surgery. The evidence available on literature, although weak, suggests that cervical collar decreases the clinical scores in first weeks after surgery. Furthermore, it does not alter the rate of fusion when used concomitantly with plaque and screws through anterior access in cervical degenerative diseases on a single anatomical level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Temporomandibular joint disorders causing limitation of mouth opening and pain may be related to the restriction of slipping or forward displacement of the mandibular condyle. Temporomandibluar arthrocentesis is the lavage of the joint and is regarded as a simple method that produces good results in patients with these symptoms. This article reports a case of disc displacement and closed lock in a patient who reported limited mouth opening and pain as the main symptoms. The treatment proposed was arthrocentesis and lavage, combining a corticosteroid with a sodium hyaluronate solution. It is concluded that arthrocentesis is a simple, efficient and barely invasive method for particular types of temporomandibular joint disorders and should be considered before opting for more invasive surgical procedures.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Thoracolumbar disk extrusion is the most common cause of extradural compression of the spinal cord in dogs. Myelography is one of the most commonly performed techniques for the diagnosis of this affection. This study aimed to evaluate the applicability and effectiveness of lumbar myelography in the diagnosis of thoracolumbar intervertebral disk extrusion in dogs, as well as its major complications. Twenty dogs were used in this study. Animals were included when neurological examination suggested thoracolumbar spine lesion, myelography was used as a complementary diagnostic method, and diagnosis of disk extrusion was surgically confirmed. The accuracy of the exam to predict location and lateralization of extruded disk material were evaluated, as well as complications associated to the procedure. Lumbar myelography exhibited 95% and 60% accuracy for location and lateralization of the lesion, respectively, with minimal complications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background. The authors compared the efficacy of bilateral balanced and canine guidance (occlusal) splints in the treatment of temporomandibular joint (TMJ) pain in subjects who experienced joint clicking with a nonoccluding splint in a double-blind, controlled randomized clinical trial.Methods. The authors randomly assigned 57 people with signs of disk displacement and TMJ pain into three groups according to the type of splint: bilateral balanced, canine guidance and nonoccluding. The authors followed the groups for six months using analysis of a visual analog scale (VAS), palpation of the TMJ and masticatory muscles, mandibular movements and joint sounds. They used repeated analysis of variance and a XI test to test the hypothesis.Results. The type of guidance used did not influence the pain reduction; yet both occlusal splints were superior to the nonoccluding splint, on the basis of the VAS. Despite similar outcomes in relation to opening, left; lateral and protrusive movements, TMJ and muscle pain on palpation, subjects who used the occlusal splints had improved clinical outcomes. The frequency of joint noises decreased over time, with no significant differences among groups. Subjects in the groups using the occlusal splints reported more comfort.Conclusion. The type of lateral guidance did not influence the subjects'; improvement: All of the subjects had a general improvement on the VAS, though subjects in the occlusal splint groups had better results that did subjects in the nonoccluding splint group.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Before epídural steroids were used in chronic lumbar pain, subarachnoid injection of these agents was the treatment of choice. Although still preconized by some authors, this technique may lead to severe complications with neurological sequelae. This report aimed at describing a case of accidental subarachnoid injection of steroid associated to local anesthetics during epidural puncture to treat lumbar pain. CASE REPORT: Male patient, 46 years old, followed byneuro-surgery for presenting right sciatic pain for 9 month, refractory to clinical treatment due to L 4-L 5 disk protrusion confirmed by CT scan, without neurological deficit. Epidural puncture for pain treatment was performed in L 4-L 5 with 17G needle and 10 mL solution were injected containing 4 mL of 0.25% bupivacaine, 80 mg methylprednisolone and 4 mL of 0.9% saline. Although there has not been CSF reflux, 5 minutes after injection there were sensory block in T 4 and motor block in T 6, associated to blood pressure and heart rate decrease. CONCLUSIONS: Accidental subarachnoid injections with the association of steroids for pain relief may cause adverse effects. There are several risks, varying from mild transient symptoms to nervous injuries, including spinal cord injuries. Our patient had no sequelae from the accidental subarachnoid injection, probably because it has been a single injection.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study quantified by, electrovibratography, the amount of mandible protrusion required to decrease significantly temporomandibular joint (TMJ) vibratory energy as an aid in the diagnosis of the recapture of anteriorly displaced disk. Eighteen patients diagnosed as having anterior disk displacement with reduction and TMJ clicking were submitted to electrovibratographic examination at the first appointment and treated with a stabilizing appliance and anterior positioning appliance with 1 to 5 mm protrusion. Vibratory energy was checked in each of these positions. Baseline data were used as control. At the first appointment, the patients had vibrations with more elevated intensities at the middle and late phases of the mouth opening cycle. At only one clinical step, mandible protrusion was obtained with the anterior repositioning appliance, ranging from 1 to 5 mm protusion. At each new position, a new electrovibratographic exam was made. After the 5-mm mandibular projection, only 2 patients presented vibration, with means between 0.6 and 2.8 Hz. Data were analyzed statistically by ANOVA and Tukey's test (α=0.05). The outcomes of this study indicate that 3 mm is the minimum amount of mandible protrusion to significantly decrease the TMJ vibratory energy and to recapture the displaced articular disk.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study on several components of intervertebral joints is essential to understand the spine's degenerative mechanisms and to assess the best method for their treatment. For such study it is necessary to know the mechanical properties of the isolated intervertebral disc (ID) mechanical properties and, it is necessary to evaluate its stresses and strains. In order to assess the ID displacements, a fine, U-shaped blade was developed, over which two extensometers connected in a Wheatstone bridge were placed. The device was then tested on porcine spine ID, where compression loads were applied and the extremities displacements of the blade coupled to the intervertebral disc were measured. Stress/strain diagram, both on the compression and on the decompression phases, evidencing the non-linear nature of such relationship. With the experiment, it was possible to obtain approximate values of the longitudinal elasticity module (E) of the disc material and of the Poisson coefficient (n ). After several tests, E results are compatible with those obtained by others studies, with very simple and low-cost device. This experiments can be used for obtained others mechanical properties of isolated ID with precision and accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Filtered ethyl ester biodiesel from residual soybean oil: performance of an agricultural tractor in the disk harrow operation. This test was conducted to evaluate the performance of an agricultural tractor using a mixture of biodiesel and petroleum diesel. The experiment was conducted at FCAV-Unesp, Jaboticabal, using a 4x2 AFWD tractor with 73.6 kW (100 hp @ 2,300 rpm) of power in the motor, pulling a disk harrow. The biodiesel used was of the ethyl type, filtered, and produced from residual soybean oil. The experimental design was completed randomized in factorial scheme (4x5), with 20 treatments and 4 repetitions, in which 5 ratios of biodiesel and petroleum diesel mixtures were combined (0 and 100%, 25 and 75%, 50 and 50%, 75 and 25% and 100 and 0%), with 4 displacement runs. The analyzed variables were traction bar power, engine rotation and displacement speed. The results evidenced that the mixture ratio (biodiesel and petroleum diesel) did not compromise tractor performance until the limit of 50%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work objectified to evaluate the efficiency of two meter mechanism of corn seeds when submitted to different forward speed and soil management system during the non-tillage seeding. It was used a factorial design in randomized blocks. The factors whose effects were examined were related to the seeders with pneumatic and horizontal disk meter mechanisms for the distribution of the seeds, to the set tractor-seeder forward speeds (4.4; 8.0 and 9.8 km h(-1)), and to the soil management system considering the corn no-tillage seeding over minimum tillage with chisel plow and the no-tillage system for the seeding of oat culture (Avena strigosa Schreb). It was verified that the forward speed didn't influence the initial and final stands of plants but it interfered in the regularity of longitudinal distribution of plants. The smallest speed provided the largest percentile of normal spacing between plants. The pneumatic meter mechanism presented better performance than the horizontal disk perforated in the longitudinal distribution of plants. About corn productivity aspect it's indifferent the recommendation of use for pneumatic and perforated horizontal disk meter mechanism of seeds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)