15 resultados para International publication ratio

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The importance of thrombosis and anticoagulation in clinical practice is rooted firmly in several fundamental constructs that can be applied both broadly and globally. Awareness and the appropriate use of anticoagulant therapy remain the keys to prevention and treatment. However, to assure maximal efficacy and safety, the clinician must, according to the available evidence, choose the right drug, at the right dose, for the right patient, under the right indication, and for the right duration of time. The first International Symposium of Thrombosis and Anticoagulation in Internal Medicine was a scientific program developed by clinicians for clinicians. The primary objective of the meeting was to educate, motivate and inspire internists, cardiologists and hematologists by convening national and international visionaries, thought-leaders and dedicated clinician-scientists in Sao Paulo, Brazil. This article is a focused summary of the symposium proceedings. © Springer Science+Business Media, LLC 2009.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Estudar prospectivamente a freqüência de complicações em pacientes tratados com warfarina e acompanhados no Ambulatório de Anticoagulação da Faculdade de Medicina de Botucatu da Universidade Estadual Paulista. MÉTODOS: Pacientes sorteados entre os agendados para consulta de junho de 2002 a fevereiro de 2004. Na primeira consulta, foi preenchida ficha com dados de identificação e clínicos. A cada retorno, ou quando o paciente procurou o hospital por intercorrência, foi preenchida ficha com a razão normatizada internacional, existência e tipo de intercorrência e condições de uso dos antagonistas da vitamina K. RESULTADOS: Foram acompanhados 136 pacientes (61 homens e 75 mulheres), 99 com tromboembolismo venoso e 37 com doença arterial; 59 pacientes eram de Botucatu, e 77, de outros municípios. Foram registradas 30 intercorrências: nove não relacionadas ao uso da warfarina e 21 complicações hemorrágicas (38,8 por 100 pacientes/ano). Uma hematêmese foi considerada grave (1,9 por 100 pacientes/ano). As demais foram consideradas moderadas ou leves. Não houve óbitos, hemorragia intracraniana ou necrose cutânea. A única associação significante foi da freqüência de hemorragia com nível médio de razão normatizada internacional. CONCLUSÃO: Nossos resultados mostram a viabilidade desse tratamento em pacientes vasculares em nosso meio, mesmo em população de baixo nível socioeconômico, quando tratados em ambulatório especializado.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Após cerca de 50 anos de experiência com a heparina e antagonistas da vitamina K (AVK), pesquisas e estudos com novos anticoagulantes vêm evoluindo de forma crescente nos últimos anos. Embora consagrados pelo uso, os anticoagulantes tradicionais têm limitações importantes em termos de controle laboratorial, complicações, efeitos colaterais, interações com medicamentos e dieta. A heparina não fracionada (HNF) tem interação com proteínas plasmáticas e parede vascular, pode desencadear trombocitopenia induzida pela heparina (TIH), só pode ser administrada por via parenteral, exige controle laboratorial pelo teste da tromboplastina parcial ativada (TTPa), pode provocar osteoporose e alopecia quando usada por períodos prolongados e sua produção tem origem biológica. A AVK tem a vantagem de poder ser ministrada por via oral, mas o controle (feito pela razão normatizada internacional) pode ser difícil em alguns casos, já que tem início de ação demorado, janela terapêutica estreita, interação com dieta e grande número de medicamentos, pode provocar necrose de pele em portadores de deficiência de antitrombina e de proteínas C e S, e pode induzir alterações fetais quando usada na gravidez. Na década de 1980, surgiram as heparinas de baixo peso molecular, que foram uma evolução da heparina não fracionada, pois apresentaram maior biodisponibilidade, dosagem por peso corporal, sem necessidade de controle laboratorial, administração por via subcutânea, menor risco de trombocitopenia induzida pela heparina, e eficácia e segurança similares à heparina não fracionada. Na última década surgiram, então, uma série de novos anticoagulantes no mercado, os quais têm apresentado resultados promissores em várias situações de profilaxia e tratamento do tromboembolismo venoso. Nesta revisão, são apresentados as novas heparinas de baixo peso molecular, as heparinas de ultrabaixo peso molecular, os pentassacarídeos, os novos inibidores diretos do fator Xa e inibidores do fator IIa.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background Diet composition is one of the factors that may contribute to intraindividual variability in the anticoagulant response to warfarin. Aim of the study To determine the associations between food pattern and anticoagulant response to warfarin in a group of Brazilian patients with vascular disease. Methods Recent and usual food intakes were assessed in 115 patients receiving warfarin; and corresponding plasma phylloquinone (vitamin K-1), serum triglyceride concentrations, prothrombin time (PT), and International Normalized Ratio (INR) were determined. A factor analysis was used to examine the association of specific foods and biochemical variables with anticoagulant data. Results Mean age was 59 +/- 15 years. Inadequate anticoagulation, defined as values of INR 2 or 3, was found in 48% of the patients. Soybean oil and kidney beans were the primary food sources of phylloquinone intake. Factor analysis yielded four separate factors, explaining 56.4% of the total variance in the data set. The factor analysis revealed that intakes of kidney beans and soybean oil, 24-h recall of phylloquinone intake, PT and INR loaded significantly on factor 1. Triglycerides, PT, INR, plasma phylloquinone, and duration of anticoagulation therapy loaded on factor 3. Conclusion Fluctuations in phylloquinone intake, particularly from kidney beans, and plasma phylloquinone concentrations were associated with variation in measures of anticoagulation (PT and INR) in a Brazilian group of patients with vascular disease.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The prothrombin time (PT) test is commonly used to monitor anticoagulant levels in patients undergoing oral anticoagulant therapy. Currently, anticoagulation levels have been assessed through the international normalized ratio (INR) value. Objective: The objective of this study was to determine if inhouse preparations of polled plasma, containing five (P5) and 20 (P20) samples, respectively, may be used as normal control of PT and to assess its interference in INR values. Material and methods: The experiment was performed in 32 days. Both polled plasma preparations were analyzed in comparison with a commercial control (PC). PT was performed for PC, P5 and P20 daily and the INR value for PC, P5 and P20 was assessed in patients undergoing oral anticoagulant therapy. The applied statistical tools were mean value (X), analysis of variance and Tukey test. Results: There were no statiscally significant differences in PT and INR for PC, P5 and P20. Conclusion: In-house polled plasma (P5 and P20) may be applied as normal control of PT and it does not interfere in the INR value.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose. The purpose of this study was to evaluate the discrepancies between abstracts presented at the IADR meeting (2004-2005) and their full-text publication. Material and Methods. Abstracts from the Prosthodontic Section of IADR meeting were obtained. The following information was collected: abstract title, number of authors, study design, statistical analysis, outcome, and funding source. PubMed was used to identify the full-text publication of the abstracts. The discrepancies between the abstract and the full-text publication were examined, categorized as major and minor discrepancies, and quantified. The data were collected and analyzed using descriptive analysis. Frequency and percentage of major and minor discrepancies were calculated. Results. A total of 109 (95.6%) articles showed changes from their abstracts. Seventy-four (65.0%) and 105 (92.0%) publications had at least one major and one minor discrepancies, respectively. Minor discrepancies were more prevalent (92.0%) than major discrepancies (65.0%). The most common minor discrepancy was observed in the title (80.7%), and most common major discrepancies were seen in results (48.2%). Conclusion. Minor discrepancies were more prevalent than major discrepancies. The data presented in this study may be useful to establish a more comprehensive structured abstract requirement for future meetings. © 2012 Soni Prasad et al.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: This study evaluated possible publication bias and its related factors in implant-related research over time. Materials and Methods: Articles published in Clinical Implant Dentistry and Related Research, Clinical Oral Implants Research, Implant Dentistry, Journal of Oral Implantology, and The International Journal of Oral & Maxillofacial Implants between 2005 and 2009 were reviewed. Nonoriginal articles were excluded. For each article included, study outcome, extramural funding source, type of study, and geographic origin were recorded. Descriptive and analytic statistics (alpha = .05), including the chi-square test and logistic regression analysis, were performed where appropriate. Results: From a total of 2,085 articles, 1,503 met the inclusion criteria. of the articles analyzed, 1,226 (81.6%), 160 (10.6%), and 117 (7.8%) articles reported positive, negative, and neutral outcomes, respectively. In vitro studies, studies from Asia, and funded animal studies were more likely to report positive outcomes compared to others (P = .02, P < .0001, and P = .009, respectively). Industry-funded studies represented the lowest frequency of positive outcomes versus studies funded by other sources. Conclusions: There were a high number of implant-related studies reporting positive outcomes in the five selected journals. Some selected factors were associated with positive outcome bias. In general, funding was not associated with a positive outcome, except for animal studies. Industry-supported research did not show any association with the publication of positive outcomes. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:1024-1032

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a simple and powerful architecture for publication and universal access to smart transducers, through existing and established open standards. Smart transducers are put to work on standards and styles already included in the Web, exploring resources in Cloud Computing and simplifying access to data. © 2012 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Soluble fms-like tyrosine kinase 1 (sFlt-1) is an anti-angiogenic factor released in higher amounts by preeclamptic placentas and it has been implicated in the endothelial dysfunction observed in the disease. In this study we evaluated if circulating sFlt-1/PlGF ratio is useful to predict adverse outcomes in women with early-onset preeclampsia. This is a cohort study of 88 preeclamptic women with singleton pregnancies at ≤35 weeks of gestation. According to definitions used, adverse outcomes occurred in 46.5% (N = 43) of the patients. The median sFlt1/PlGF ratio (25th-75th centile) for all patients evaluated was of 42.26 (13.1-226.1). The median sFlt-1/PlGF ratio among women who had any adverse outcome (N = 43) versus no adverse outcomes (N = 45) was of 227.6 (80.3-346.1) versus 14.4 (3.35-30.0), (P < 0.0001). According to our analyses a sFlt-1/PlGF ratio cut-point of ≥85 gave a sensitivity of 74.0% and specificity of 97.0%. The positive predictive value and the negative predictive value were 96.0% and 80.0%, respectively. The median sFlt-1/PlGF ratio (25th-75th centile) for patients who delivered within <7 days was 260.0 (127.7-404.7) as compared to 14.4 (3.35-34.97) for those patients who delivered within two weeks or more (P < 0.0001). Our results suggest that sFlt-1/PlGF ratio is a promising marker for adverse outcomes in women with early-onset preeclampsia. © 2013 International Society for the Study of Hypertension in Pregnancy. Published by Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A Scientific Committee on Problems of the Environment Rapid Assessment (SCOPE-RAP) workshop was held on 18-22 March 2013. This workshop was hosted by the European Commission, JRC Centre at Ispra, Italy, and brought together 40 leading experts from Africa, Asia, Europe and North and South America to create four synthesis chapters aimed at identifying knowledge gaps, research requirements, and policy innovations. Given the forthcoming publication by CABI of a book volume of the outcomes of the SCOPE-RAP in 2014, this workshop report provides an update on the global societal challenge of soil carbon management and some of the main issues and solutions that were identified in the four working sessions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to assess the contributions of some prosthetic parameters such as crown-to-implant (C/I) ratio, retention system, restorative material, and occlusal loading on stress concentrations within a single posterior crown supported by a short implant. Materials and Methods: Computer-aided design software was used to create 32 finite element models of an atrophic posterior partially edentulous mandible with a single external-hexagon implant (5 mm wide × 7 mm long) in the first molar region. Finite element analysis software with a convergence analysis of 5% to mesh refinement was used to evaluate the effects of C/I ratio (1:1; 1.5:1; 2:1, or 2.5:1), prosthetic retention system (cemented or screwed), and restorative material (metal-ceramic or all ceramic). The crowns were loaded with simulated normal or traumatic occlusal forces. The maximum principal stress (σmax) for cortical and cancellous bone and von Mises stress (σvM) for the implant and abutment screw were computed and analyzed. The percent contribution of each variable to the stress concentration was calculated from the sum of squares analysis. Results: Traumatic occlusion and a high C/I ratio increased stress concentrations. The C/I ratio was responsible for 11.45% of the total stress in the cortical bone, whereas occlusal loading contributed 70.92% to the total stress in the implant. The retention system contributed 0.91% of the total stress in the cortical bone. The restorative material was responsible for only 0.09% of the total stress in the cancellous bone. Conclusion: Occlusal loading was the most important stress concentration factor in the finite element model of a single posterior crown supported by a short implant.