184 resultados para Instrumented Indentation

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

2,25Cr-1Mo alloy steels are widely used in petrochemical plant equipments working in high temperature conditions because of their good mechanical proprieties in these conditions. Although, when exposed for a long time at high temperature, in the rage of 343 °C to 593 °C, may present the temper embrittlement phenomenon. The component named stripper of assembly converter of fluid catalytic cracking unit (UFCC) of studied plant is manufactured using this material, which is subject to temper embrittlement. The phenomenon of temper embrittlement refers to progressive lose of toughness, making the material brittle. With embrittlement, equipaments manufactured with this material are under risks to suffer brittle fracture in the cool down and start-up situations of them, which can cause catastrophic failures. By this reason, this research studies presence of temper ebrittlement phenomenon on this material. To verify the toughness of the material is conventionally used charpy V-notch test. However, this test requires the removing of samples of the material to make specimens. This fact becomes critical when talk about structural components of an equipment. So, this research also studies a non-destructive test that can be executes in-situ, known as instrumented indentation, as an alternative detection of the phenomenon at the component stripper, by comparative of the mechanical proprieties obtained by conventional tests in similar samples

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Avaliaram-se as alterações do proteinograma sérico de eqüinos submetidos à isquemia e reperfusão do cólon menor por distensão intraluminal. Foram utilizados 10 animais submetidos à laparotomia pelo flanco, em posição quadrupedal, para a indução de obstrução no cólon menor durante um período de quatro horas. Cinco animais foram instrumentados, mas sem distensão (grupo controle - G1). em cinco outros animais, foi realizada isquemia mural por distensão do cólon menor via manguito inflado com 40mmHg (grupo distendido - G2). Foram colhidas amostras de sangue antes da intervenção cirúrgica (M1), com 4 horas da colocação do manguito (M2) e com 3 horas (M3) e 12 horas (M4) de reperfusão. Após centrifugação e fracionamento das amostras, as proteínas de fase aguda foram separadas por eletroforese em gel de poliacrilamida contendo SDS-PAGE, e suas concentrações determinadas por densitometria computadorizada. Foram encontradas 19 proteínas no fracionamento eletroforético, com peso molecular variando de 185.000 a 14.000 Daltons (Da). Os pesos moleculares encontrados, correspondentes às proteínas mais conhecidas, foram ceruloplasmina, 130.000 Da; proteína C-reativa, 122.000 Da; transferrina, 85.000 Da; α1-antitripsina, 61.000 Da; haptoglobina, 47.000 Da; e glicoproteína ácida, 40.000 Da. Os resultados mostram que proteínas de fase aguda se alteram após o trauma cirúrgico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Activities that use Global Navigation Satellite System (GNSS) are countless and the most used one is the Global Positioning System (GPS) developed by the United States. In precision agriculture there are demands for static and cinematic positioning with distinct levels of accuracy for different applications; nevertheless cinematic performance data are not available as manufacturers of GPS receivers present only static performance information. For this reason it was developed an instrumented vehicle to test a methodology of performance evaluation of GPS receivers in kinematic conditions, which is representative to agricultural operations. A set of instrumentation was composed and used for collecting data under variable speed and rotation direction. Tests were conducted showing that the methodology allows to measure accuracy and precision, but improvements have to be implemented on the instrumentation equipment for long term tests.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper presents the results of instrumented compression load tests carried out in three uncased cast-in-place piles (pounded piles, called apiloadas in Brazil) which is largely used in interior part of the state of São Paulo. The tests were conducted with the soil in the natural condition and after soaking with water, before loading, in order to evaluate the influence of the soil collapsibility in the results. The values of the ultimate loads (total, point and lateral loads) obtained in the tests are presented and compared with the values predicted by empirical methods that utilize SPT and CPT results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Titanium alloys have several advantages over ferrous and non-ferrous metallic materials, such as high strengthto-weight ratio and excellent corrosion resistance. A blended elemental titanium powder metallurgy process has been developed to offer low cost commercial products. The process employs hydride-dehydride (HDH) powders as raw material. In this work, results of the Ti-35Nb alloy sintering are presented. This alloy due to its lower modulus of elasticity and high biocompatibility is a promising candidate for aerospace and medical use. Samples were produced by mixing of initial metallic powders followed by uniaxial and cold isostatic pressing with subsequent densification by isochronal sintering between 900 up to 1600 °C, in vacuum. Sintering behavior was studied by means of microscopy and density. Sintered samples were characterized for phase composition, microstructure and microhardness by X-ray diffraction, scanning electron microscopy and Vickers indentation, respectively. Samples sintered at high temperatures display a fine plate-like alpha structure and intergranular beta. A few remaining pores are still found and density above 90% for specimens sintered in temperatures over 1500 °C is reached.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Investigar a influência do inibidor não-seletivo da ciclooxigenase, cetoprofeno (ceto) intravenoso, em alterações histológicas e dos níveis das citocinas renais - fator α de necrose tumoral (TNF- α) e interleucina 1 (IL-1) - após hemorragia de 30% da volemia (10%, três vezes, em intervalos de 10 min). MÉTODOS: Sob anestesia com sevoflurano (sevo), os grupos sevo e sevo+ceto (10 ratos cada) foram preparados cirurgicamente para leitura de pressão arterial média (PAM) e administração de solução de Ringer (5 mL/kg/h) e de cetoprofeno (1,5 mg/kg), no início da anestesia, no grupo sevo+ceto. Mediu-se temperatura retal continuamente. Os valores de temperatura e PAM foram observados antes da primeira hemorragia (T1), após a terceira hemorragia (T2) e 30 min após T2 (T3). Realizada nefrectomia bilateral nos dois grupos para análise histológica e imuno-histoquímica. RESULTADOS: Nos dois grupos, temperatura e PAM diminuíram com relação aos valores basais. Hipotermia foi mais acentuada no grupo sevo (p=0,0002). Necrose tubular foi mais frequente no grupo sevo (p=0,02). As citocinas estiveram igualmente presentes nos rins dos dois grupos. CONCLUSÃO: Cetoprofeno foi mais protetor no rim de rato durante anestesia com sevoflurano e hipovolemia, porém parece que TNF- α e IL-1 não estão envolvidas nessa proteção.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several local factors that influence the healing process of replanted teeth have been investigated. However, it remains unclear how systemic alterations, such as diabetes mellitus, affect the prognosis of these cases. The purpose of this study was to evaluate the healing process of incisors of non-controlled diabetic rats replanted after storage in bovine long shelf-life (UHT) whole milk. Thirty-two rats were randomly assigned to receive an endovenous injection of either citrate buffer solution (group I - control; n = 16) or streptozotocin dissolved in citrate buffer solution to induce diabetes (group II; n = 16). After confirmation of the diabetic status by analysis of the glycemic levels, the maxillary right incisor of each animal was extracted and immersed in milk for 60 min. The root canals of teeth were then instrumented, and were filled with a calcium hydroxide-based dressing and replanted into their sockets. All animals received systemic antibiotic and were killed by anesthetic overdose 10 and 60 days after replantation. The specimens containing the replanted teeth were removed, fixed, decalcified, and embedded in paraffin. Semi-serial 6-mu m-thick sections were obtained and stained with hematoxylin and eosin for histologic and histometric analyses. The results showed that the connective tissue adjacent to the root surface was less organized in the diabetic animals than in the control animals in both periods; the root dentin was less severely affected by root resorption in the diabetic rats; there were no significant differences between the control and diabetic groups regarding the occurrence of replacement resorption and inflammatory resorption.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Euro-Collins solution was developed for the preservation of organs for transplantation, whose characteristics have raised interest for its use as a storage medium for avulsed teeth before replantation. This study evaluated histologically and morphometrically the healing process of dog teeth replanted after storage in Euro-Collins solution or bovine milk.Materials and Methods: Eighty roots of 4 young adult mongrel clogs were randomly assigned to 4 groups (n = 20) and the root canals were instrumented and obturated with gutta-percha and a calcium hydroxide-based sealer. After 2 weeks, the teeth were extracted and subjected to the following protocols: GI (negative control), replantation immediately after extraction; GII (positive control), bench-drying for 2 hours before replantation; GIII and GIV, immersion in 10 mL of whole bovine milk and Euro-Collins solution at 4 C, respectively, for 8 hours before replantation. The animals were sacrificed 90 days postoperatively. The pieces containing the replanted teeth were subjected to routine processing for histologic and histometric analyses under light microscopy and polarized light microscopy.Results: Root resorption was observed in all groups. GII exhibited the greatest loss of dental structure (P < .01), and inflammatory resorption was predominant in this group. Storage in milk showed poorer results than immediate replantation and storage in Euro-Collins solution (P < .01). The teeth stored in Euro-Collins solution presented similar extension of root resorption and periodontal ligament reorganization to those of immediately replanted teeth.Conclusions: The findings of this study suggest that the Euro-Collins solution is an adequate storage medium for keeping avulsed teeth for up to 8 hours before replantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Minimal extraoral dry storage period and moist storage for the avulsed tooth are identified as key steps for the treatment protocol of tooth replantation. Among the possible moist storage media, bovine milk has stood out because of its capacity of preserving the integrity of the periodontal ligament (PDL) fibers. This condition has attracted the attention to investigate the use of powdered milk, which is one of the presentation forms of bovine milk, as a feasible storage medium in cases of delayed tooth replantation. The aim of this study was to evaluate the healing process after delayed replantation of rat teeth stored in reconstituted powdered milk and long shelf-life (ultra high temperature) whole milk. Forty maxillary right rat incisors were assigned to four groups (n = 10): group I - the teeth were extracted and immediately replanted into theirs sockets; group II - the teeth were stored for 60 min in 200 ml of freshly reconstituted powdered milk; group III - the teeth were stored for 60 min in 200 ml of long shelf-life whole milk; group IV - the teeth were kept dry for the same time. All procedures were performed at room temperature. Next, the root canals of teeth in groups II, III, and IV were instrumented, filled with a calcium hydroxide-based paste, and replanted into their sockets. All animals received systemic antibiotic therapy and were killed by anesthetic overdose 60 days after replantation. The pieces containing the replanted teeth were removed, fixed, decalcified, and paraffin-embedded. Semi-serial 6-mu m-thick sections were obtained and stained with hematoxylin and eosin for histomorphological analysis. There was statistically significant difference (P < 0.05) between groups I and IV regarding the presence of replacement resorption and PDL remnants on root surface. The powdered milk and long shelf-life whole milk presented similar results to each other and may be indicated as storage media for avulsed teeth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Foi propósito deste estudo analisar a influência da infiltração marginal coronária no comportamento dos tecidos periapicais de dentes de cães após obturação de canal e preparo para pino. Quarenta canais de dentes de cães foram instrumentados e obturados pela técnica da condensação lateral com cones de guta percha e os cimentos Roth e Sealer 26. Após preparo para pino, o remanescente da obturação foi protegido ou não com um plug do cimento temporário Lumicon. Após exposição ao meio oral por 90 dias, os animais foram sacrificados e as peças preparadas para análise histomorfológica. A técnica de Brown e Brenn mostrou 70% de casos com infiltração de microrganismos para o cimento Roth e 20% com o Sealer 26. Quando um plug de Lumicon foi empregado ocorreu 30% de casos de infiltração de microrganismos com o cimento Roth e 0,0% com o cimento Sealer 26. Reação inflamatória crônica foi mais freqüentemente observada com o cimento Roth do que com o Sealer 26. Foi concluído que o plug de Lumicon é eficiente no controle da infiltração coronária (p=0.05) e que o Sealer 26 foi mais biocompatível e selou melhor os canais radiculares do que o cimento Roth (p=0.01).