36 resultados para Instantaneous space vector

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the important issues about using renewable energy is the integration of dispersed generation in the distribution networks. Previous experience has shown that the integration of dispersed generation can improve voltage profile in the network, decrease loss, etc. but can create safety and technical problems as well. This work report the application of the instantaneous space phasors and the instantaneous complex power in observing performances of the distribution networks with dispersed generators in steady state. New IEEE apparent power definition, the so-called Buchholz-Goodhue effective apparent power, as well as new proposed power quality (oscillation) index in the three-phase distribution systems with unbalanced loads and dispersed generators, are applied. Results obtained from several case studies using IEEE 34 nodes test network are presented and discussed. (C) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the instantaneous-space-phasor (ISP) definition and describes its properties and possible applications for three-phase systems. It is shown that the ISP provides the mathematical base for a new approach to the measurement of active, reactive, and apparent power. Moreover, the ISP helps separate the positive and negative-sequence components and fits perfectly into the Buchholz-Goodhue apparent power definition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the important issues about using renewable energy is the integration of dispersed generation in the distribution networks. Previous experience has shown that the integration of dispersed generation can improve voltage profile in the network, decrease loss etc. but can create safety and technical problems as well, This work report the application of the instantaneous space phasors and the instantaneous complex power in observing performances of the distribution networks with dispersed generators in steady state. New IEEE apparent power definition, the so called Buccholz-Goodhue apparent power, as well as new proposed power quality (oscillation) index in the three-phase distribution systems with unbalanced loads and dispersed generators, are applied. Results obtained from several case studies using IEEE 34 nodes test network are presented and discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Space Vector PWM implementation and operation for a Four-leg Voltage Source Inverter (VSI) is detailed and discussed in this paper. Although less common, four-leg VSIs are a viable solution for situations where neutral connection is necessary, including Active Power Filter applications. This topology presents advantages regarding the VSI DC link and capacitance, which make it useful for high power devices. Theory, implementation and simulations are also discussed in this paper. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work is to present a modified Space Vector Modulation (SVM) suitable for Tri-state Three-phase inverters. A standard SVM algorithm and the Tri-state PWM (Pulse Width Modulation) are presented and their concept are mixed into the novel SVM. The proposed SVM is applied to a three-phase tri-state integrated Boost inverter, intended to Photovoltaic Energy Applications. The main features for this novel SVM are validated through simulations and also by experimental tests. The obtained results prove the feasibility of the proposal. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a three-phase integrated inverter suitable for stand-alone and grid-connected applications. Furthermore, the utilization of the special features of the tri-state coupled with the new space vector modulation allows the converter to present an attractive degree of freedom for the designing of the controllers. Additionally, the control is derived through dq0 transformation, all the system is described and interesting simulation results are available to confirm the proposal. © 2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Unbalance and harmonics are two major distortions in the three-phase distribution systems. In this paper an investigation into unbalance phenomena in the distribution networks using instantaneous space vector theory, is presented. Power oscillation index (POI) and effective power factor (PFe) are calculated in the network nodes for several unbalance loading conditions. For system analysis a general power flow algorithm for three-phase four-wire radial distribution networks, based on backward-forward technique, is applied. Results obtained from several case studies using medium and low voltage test feeder with unbalanced load, are presented and discussed. © 2010 Praise Worthy Prize S.r.l. - All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The theory presented in this paper was primarily developed to give a physical interpretation for the instantaneous power flow on a three-phase induction machine, without a neutral conductor, on any operational state and may be extended to any three-phase load. It is a vectorial interpretation of the instantaneous reactive power theory presented by Akagi et al. Which, believe the authors, isn't enough developed and its physical meaning not yet completely understood. This vectorial interpretation is based on the instantaneous complex power concept defined by Torrens for single-phase, ac, steady-state circuits, and leads to a better understanding of the power phenomenon, particularly of the distortion power. This concept has been extended by the authors to three-phase systems, through the utilization of the instantaneous space vectors. The results of measurements of instantaneous complex power on a self-excited induction generator's terminals, during an over-load application transient, are presented for illustration. The compensation of reactive power proposed by Akagi is discussed and a new horizon for the theory application is opened.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper explains the conceptual design of instrumentation that measures electric quantities defined in the Std. 1459-2000. It is shown how the instantaneous-space-phasor approach, based on alpha, beta, 0 components, can be used to monitor electric energy flow, evaluate the utilization of transmission line, and quantify the level of harmonic pollution injected by nonlinear loads.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The paper explains the conceptual design of instrumentation that measures electric quantities defined in the trial-use Std. 1459-2000. It is shown how the Instantaneous-Space-Phasor (ISP) approach, based on α, β, 0 components, can be used to monitor electric energy flow, evaluate the utilization of transmission line and quantify the level of harmonic pollution injected by nonlinear loads.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Voltage source inverters use large electrolytic capacitors in order to decouple the energy between the utility and the load, keeping the DC link voltage constant. Decreasing the capacitance reduces the distortion in the inverter input current but this also affects the load with low-order harmonics and generate disturbances at the input voltage. This paper applies the P+RES controller to solve the challenge of regulating the output current by means of controlling the magnitude of the current space vector, keeping it constant thus rejecting harmonic disturbances that would otherwise propagate to the load. This work presents a discussion of the switching and control strategy. © 2011 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents a three-phase integrated inverter suitable for stand-alone and/or grid-connected applications. The usage of the special features of the tri-state coupled with the special space vector modulation allows the inverter to present an attractive degree of freedom for the controllers' design, i.e. input and output can be controlled independently. Additionally all controllers are based on dq0 transformation, the system are described and interesting simulation results are available to confirm the proposal. Finally, this paper presents experimental evaluations of the inverter feeding a three-phase stand-alone load confirming the remarkable features of the decoupling control. © 2013 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)