4 resultados para INTERMITTENCY

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gas of non-interacting particles diffuses in a lattice of pulsating scatterers. In the finite-horizon case with bounded distance between collisions and strongly chaotic dynamics, the velocity growth (Fermi acceleration) is well described by a master equation, leading to an asymptotic universal non-Maxwellian velocity distribution scaling as v∼t. The infinite-horizon case has intermittent dynamics which enhances the acceleration, leading to v∼t ln t and a non-universal distribution. © Copyright EPLA, 2013.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is no consensus in the literature on the best renal replacement therapy (RRT) in acute kidney injury (AKI), with both hemodialysis (HD) and peritoneal dialysis (PD) being used as AKI therapy. However, there are concerns about the inadequacy of PD as well as about the intermittency of HD complicated by hemodynamic instability. Recently, continuous replacement renal therapy (CRRT) have become the most commonly used dialysis method for AKI around the world. A prospective randomized controlled trial was performed to compare the effect of high volume peritoneal dialysis (HVPD) with daily hemodialysis (DHD) on AKI patient survival. A total of 120 patients with acute tubular necrosis (ATN) were assigned to HVPD or DHD in a tertiary-care university hospital. The primary end points were hospital survival rate and renal function recovery, with metabolic control as the secondary end point. Sixty patients were treated with HVPD and 60 with DHD. The HVPD and DHD groups were similar for age ( 64.2 +/- 19.8 and 62.5 +/- 21.2 years), gender ( male: 72 and 66%), sepsis ( 42 and 47%), hemodynamic instability ( 61 and 63%), severity of AKI ( Acute Tubular Necrosis-Index Specific Score (ATN-ISS): 0.68 +/- 0.2 and 0.66 +/- 0.2), Acute Physiology, Age, and Chronic Health Evaluation Score (APACHE II) (26.9 +/- 8.9 and 24.1 +/- 8.2), pre-dialysis BUN (116.4 +/- 33.6 and 112.6 +/- 36.8mg per 100 ml), and creatinine ( 5.8 +/- 1.9 and 5.9 +/- 1.4 mg per 100 ml). Weekly delivered Kt/V was 3.6 +/- 0.6 in HVPD and 4.7 +/- 0.6 in DHD ( P<0.01). Metabolic control, mortality rate ( 58 and 53%), and renal function recovery ( 28 and 26%) were similar in both groups, whereas HVPD was associated with a significantly shorter time to the recovery of renal function. In conclusion, HVPD and DHD can be considered as alternative forms of RRT in AKI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We identify and analyze quasiperiodic and chaotic motion patterns in the time evolution of a classical, non-Abelian Bogomol'nyi-Prasad-Sommerfield (BPS) dyon pair at low energies. This system is amenable to the geodesic approximation which restricts the underlying SU(2) Yang-Mills-Higgs dynamics to an eight-dimensional phase space. We numerically calculate a representative set of long-time solutions to the corresponding Hamilton equations and analyze quasiperiodic and chaotic phase space regions by means of Poincare surfaces of section, high-resolution power spectra and Lyapunov exponents. Our results provide clear evidence for both quasiperiodic and chaotic behavior and characterize it quantitatively. Indications for intermittency are also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents one proposal of the energy management's model system using photovoltaic panels. The module proposed seeks to monitor photovoltaic panels, which have intermittency in power generation caused by environmental or load conditions, in order to control the coupling between the panel and the load - through the charge controller, of aiming that the panel's operation will be always on the maximum power transfer point as possible. For this, it used the maximum power point tracking technique - MPPT, implemented in LabVIEW software, also utilizing the data acquisition card NI myDAQ. In addition, it was implemented the controller access remote module, from the sharing of network data, so the panels performance can be through a tablet, monitored and controlled with no need for direct contact with the Supervisory server