7 resultados para Harmonized standards

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has previously been shown that measurement of the critical speed is a non-invasive method of estimating the blood lactate response during exercise. However, its validity in children has yet to be demonstrated. The aims of this study were: (1) to verify if the critical speed determined in accordance with the protocol of Wakayoshi et al. is a non-invasive means of estimating the swimming speed equivalent to a blood lactate concentration of 4 mmol . l(-1) in children aged 10-12 years; and (2) to establish whether standard of performance has an effect on its determination. Sixteen swimmers were divided into two groups: beginners and trained. They initially completed a protocol for determination of speed equivalent to a blood lactate concentration of 4 mmol . l(-1). Later, during training sessions, maximum efforts were swum over distances of 50, 100 and 200 m for the calculation of the critical speed. The speeds equivalent to a blood lactate concentration of 4 mmol . l(-1) (beginners = 0.82 +/- 0.09 m . s(-1), trained = 1.19 +/- 0.11 m . s(-1); mean +/- s) were significantly faster than the critical speeds (beginners = 0.78 +/- 0.25 m . s(-1), trained = 1.08 +/- 0.04 m . s(-1)) in both groups. There was a high correlation between speed at a blood lactate concentration of 4 mmol . l(-1) and the critical speed for the beginners (r = 0.96, P < 0.001), but not for the trained group (r = 0.60, P > 0.05). The blood lactate concentration corresponding to the critical speed was 2.7 +/- 1.1 and 3.1 +/- 0.4 mmol . l(-1) for the beginners and trained group respectively. The percent difference between speed at a blood lactate concentration of 4 mmol . l(-1) and the critical speed was not significantly different between the two groups. At all distances studied, swimming performance was significantly faster in the trained group. Our results suggest that the critical speed underestimates swimming intensity corresponding to a blood lactate concentration of 4 mmol . l(-1) in children aged 10-12 years and that standard of performance does not affect the determination of the critical speed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article addresses the establishment of integrated diagnostics and recommendation system (DRIS) standards for irrigated bean crops (Phaseolus vulgaris) and compares leaf concentrations and productivity in low- and high-productivity populations. The work was carried out in Santa Fe de Goias, Goias State, Brazil, in the agricultural years 1999/2000 and 2000/2001. For the nutritional diagnosis, leaf samples were collected, and leaf concentrations of nitrogen (N), phosphorus (P), potassium (K), calcium (Ca), magnesium (Mg), sulfur (S), boron (B), copper (Cu), iron (Fe), manganese (Mn), and zinc (Zn) were established in 100 commercial bean crops. A database was set up listing the leaf nutrient content and the respective productivities, subdivided into two subpopulations, high and low productivity, using a bean yield value of 3000 kg ha-1 to separate these subpopulations. Sufficiency values found in the high-productivity population matched only for the micronutrients B and Zn. The nutritional balance among the populations studied was coherent and was lower in the high-productivity population. The DRIS standards proposed for irrigated bean farming were efficient in evaluating the nutritional status of the crop areas studied. Calcium, Cu, and S were found to be the least available nutrients, indicating high response potential for the fertilizing using these nutrients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compositional data from 152 stingless bee (Meliponini) honey samples were compiled from studies since 1964, and evaluated to propose a quality standard for this product. Since stingless bee honey has a different composition than Apis mellifera honey, some physicochemical parameters are presented according to stingless bee species. The entomological origin of the honey was known for 17 species of Meliponini from Brazil, one from Costa Rica, six from Mexico, 27 from Panama, one from Surinam, two from Trinidad & Tobago, and seven from Venezuela, most from the genus Melipona. The results varied as follows: moisture (19.9-41.9g/100g), pH (3.15-4.66), free acidity (5.9-109.0meq/Kg), ash (0.01-1.18g/100g), diastase activity (0.9-23.0DN), electrical conductivity (0.49-8.77mS/cm), HMF (0.4-78.4mg/Kg), invertase activity (19.8-90.1IU), nitrogen (14.34-144.00mg/100g), reducing sugars (58.0-75.7g/100g) and sucrose (1.1-4.8g/100g). Moisture content of stingless bee honey is generally higher than the 20% maximum established for A. mellifera honey. Guidelines for further contributions would help make the physicochemical database of meliponine honey more objective, in order to use such data to set quality standards. Pollen analysis should be directed towards the recognition of unifloral honeys produced by stingless bees, in order to obtain standard products from botanical species. A honey quality control campaign directed to both stingless beekeepers and stingless bee honey hunters is needed, as is harmonization of analytical methods. © 2007 Asociación Interciencia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose: The circadian rhythm of melatonin in saliva or plasma, or of the melatonin metabolite 6-sulfatoxymelatonin (a6MTs) in urine, is a defining feature of suprachiasmatic nucleus (SCN) function, the body's endogenous oscillatory pacemaker. The primary objective of this review is to ascertain the clinical benefits and limitations of current methodologies employed for detection and quantification of melatonin in biological fluids and tissues. Data Identification: A search of the English-language literature (Medline) and a systematic review of published articles were carried out. Study Selection: Articles that specified both the methodology for quantifying melatonin and indicated the clinical purpose were chosen for inclusion in the review. Data Extraction: The authors critically evaluated the methodological issues associated with various tools and techniques (e.g. standards, protocols, and procedures). Results of Data Synthesis: Melatonin measurements are useful for evaluating problems related to the onset or offset of sleep and for assessing phase delays or advances of rhythms in entrained individuals. They have also become an important tool for psychiatric diagnosis, their use being recommended for phase typing in patients suffering from sleep and mood disorders. Additionally, there has been a continuous interest in the use of melatonin as a marker for neoplasms of the pineal region. Melatonin decreases such as found with aging are or post pinealectomy can cause alterations in the sleep/wake cycle. The development of sensitive and selective methods for the precise detection of melatonin in tissues and fluids has increasingly been shown to have direct relevance for clinical decision making. Conclusions: Due to melatonin's low concentration, as well as the coexistence of numerous other compounds in the blood, the routine determination of melatonin has been an analytical challenge. The available evidence indicates however that these challenges can be overcome and consequently that evaluation of melatonin's presence and activity can be an accessible and useful tool for clinical diagnosis. © Springer-Verlag 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)