96 resultados para Harmonic contents

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

70.00% 70.00%

Publicador:

Resumo:

A neural method is presented in this paper to identify the harmonic components of an ac controller. The components are identified by analyzing the single-phase current waveform. The method effectiveness is verified by applying it to an active power filter (APF) model dedicated to the selective harmonic compensation. Simulation results using theoretical and experimental data are presented to validate the proposed approach. © 2008 IEEE.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

An alternative method is presented in this paper to identify the harmonic components of non-linear loads in single phase power systems based on artificial neural networks. The components are identified by analyzing the single phase current waveform in time domain in half-cycle of the ac voltage source. The proposed method is compared to the fast Fourier transform. Simulation and experimental results are presented to validate the proposed approach.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper introduces novel zero-current-switching (ZCS) pulsewidth-modulated (PWM) preregulators based on a new soft-commutation cell, suitable for insulated gate bipolar transistor applications. The active switches in these proposed rectifiers turn on in zero current and turn off in zero current-zero voltage. In addition, the diodes turn on in zero voltage and their reverse-recovery effects over the active switches are negligible. Moreover, based on the proposed cell, an entire family of de-to-de ZCS-PWM converters can be generated, providing conditions to obtain naturally isolated converters, for example, derived buck-boost, Sepic. and Zeta converters. The novel ac-to-dc ZCS-PWM boost and Zeta preregulators are presented in order to verify the operation of this soft-commutation cell, In order to minimize the harmonic contents of the input current, increasing the ac power factor, the average-current-mode control is used, obtaining preregulators with ac power factor near unity and high efficiency at wide load range. The principle of operation, theoretical analysis, design example, and experimental results from test units for the novel preregulators are presented. The new boost preregulator was designed to nominal values of 1.6 kW output power, 220 V(rms) input voltage, 400 V(dc) output voltage, and operating at 20 kHz. The measured efficiency and power factor of the new ZCS-PWM boost preregulator were 96.7% and 0,99, respectively, with an input current total harmonic distortion (THD) equal to 3.42% for an input voltage with THD equal to 1.61%, at rated load, the new ZCS-PWM Zeta preregulator was designed to voltage step-down operation, and the experimental results were obtained from a laboratory prototype rated at 500 W, 220 V(rm), input voltage, 110 V(dc) output voltage, and operating at 50 kHz. The measured efficiency of the new ZCS-PWM Zeta preregulator is approximately 96.9% and the input power factor is 0.98, with an input current THD equal to 19.07% while the input voltage THD is equal to 1.96%, at rated load.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The behaviors of an arc-shaped stator induction machine (the sector-motor) and a disc-secondary linear induction motor are analyzed in this work for different values of the frequency. Variable frequency is produced by a voltage source controlled-current inverter which keeps constant the r.m.s. value of the phase current, also assuring a sinusoidal waveform. For the simulations of the machine developed thrust, an equivalent circuit is used. It is obtained through the application of the one-dimensional theory to the modeling. The circuit parameters take into account the end effects, always present is these kind of machines. The phase current waveforms are analyzed for their harmonic contents. Experimental measurements were carried out in laboratory and are presented with the simulations, for comparison.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Grinding is a parts finishing process for advanced products and surfaces. However, continuous friction between the workpiece and the grinding wheel causes the latter to lose its sharpness, thus impairing the grinding results. This is when the dressing process is required, which consists of sharpening the worn grains of the grinding wheel. The dressing conditions strongly affect the performance of the grinding operation; hence, monitoring them throughout the process can increase its efficiency. The objective of this study was to estimate the wear of a single-point dresser using intelligent systems whose inputs were obtained by the digital processing of acoustic emission signals. Two intelligent systems, the multilayer perceptron and the Kohonen neural network, were compared in terms of their classifying ability. The harmonic content of the acoustic emission signal was found to be influenced by the condition of dresser, and when used to feed the neural networks it is possible to classify the condition of the tool under study.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Grinding is a workpiece finishing process for advanced products and surfaces. However, the constant friction between workpiece and grinding wheel causes the latter to lose its sharpness, thereby impairing the result of the grinding process. When this occurs, the dressing process is essential to sharpen the worn grains of the grinding wheel. The dressing conditions strongly influence the performance of the grinding operation; hence, monitoring them throughout the process can increase its efficiency. The purpose of this study was to classify the wear condition of a single-point dresser using intelligent systems whose inputs were obtained by digitally processing acoustic emission signals. Two multilayer perceptron (MLP) neural networks were compared for their classification ability, one using the root mean square (RMS) statistics and another the ratio of power (ROP) statistics as input. In this study, it was found that the harmonic content of the acoustic emission signal is influenced by the condition of the dresser, and that the condition of the tool under study can be classified by using the aforementioned statistics to feed a neural network. © IFAC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amostras quinzenais, desde o parto até o final do período de lactação, obtidas de 34 vacas de três diferentes raças e propriedades, foram analisadas quanto à presença de GMP livre. Um pool das amostras quinzenais de cada rebanho foi analisada tanto para o conteúdo de GMP livre quanto para o GMP total (liberado da k-caseína pela ação da renina), correlacionando-os com as condições sanitárias do animal e do úbere, à fase da lactação e à produção de leite. A maioria dos problemas sanitários concentrou-se próximo ao parto, com poucas e espaçadas ocorrências de mastites clínicas. Os resultados do teste de CMT mostraram reações compatíveis às fases da lactação. Para o GMP livre as maiores variações ocorreram em função do período de lactação e em conseqüência de mastites clínicas e subclínicas. Valores elevados foram observados no início da lactação (5,87mg de ácido siálico/L de leite), normalizando para valores próximos de 3,30mg/L já ao final do segundo mês e voltando a elevar-se no terço final da lactação. em média, as mesmas tendências foram observadas para o teor de GMP total liberado pela ação de coalho comercial, iniciando com valores ligeiramente elevados (35,59mg/L), tornando-se normal e assim se mantendo até o sexto mês com valores próximos a 27,15mg/L, e novamente elevando-se gradualmente até o final da lactação, com 58,35mg de ácido siálico/L de leite. Esses resultados mostram-se úteis para a correta interpretação de métodos aplicados à seleção do leite, seja em relação ao status proteolítico da matéria-prima ou mesmo para coibição de fraudes por adição de soro ao leite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O empirismo no uso das soluções nutritivas é freqüente. Muitas vezes a mesma solução nutritiva é usada para diferentes espécies baseando-se apenas em semelhanças morfológicas. No entanto esta situação pode proporcionar desequilíbrio nutricional prejudicando tanto a produção quanto a qualidade do produto face o acúmulo de nitrato. Foi conduzido um trabalho em sistema hidropônico - NFT, com o objetivo de avaliar o efeito da concentração de nitrogênio na solução nutritiva na produção, nos teores de nutrientes e de nitrato em folhas de rúcula (Eruca sativa). O trabalho foi conduzido na primavera de 2003. Foram avaliadas quatro concentrações de nitrogênio na solução nutritiva (60,8; 121,6; 182,5; 243,5 mg L-1) e três cultivares de rúcula (Cultivada, Folha Larga e Selvática), sob delineamento de blocos ao acaso, fatorial 4 x 3, com quatro repetições. A cv. Cultivada apresentou maior estatura e fitomassa fresca de folhas, não diferindo da 'Folha Larga' quanto a número de folhas, teor de nitrato nas folhas e fitomassa seca e fresca da raiz. Houve incremento de NO3-, N, Ca e P e diminuição de Mg, K e S com o aumento da concentração de N na solução nutritiva. O cultivo da cv. Cultivada na concentração de 93 mg L-1 é a mais recomendada em função da maior produtividade e baixo teor de nitrato.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A tungsten carbide coating on the integrated platform of a transversely heated graphite atomizer was used as a modifier for the direct determination of Se in soil extracts by graphite furnace atomic absorption spectrometry. Diethylenetriaminepentaacetic acid (0.0050 mol L-1) plus ammonium hydrogencarbonate (1.0 mol L-1) extracted predominantly available inorganic selenate from soil. The formation of a large amount of carbonaceous residue inside the atomizer was avoided with a first pyrolysis step at 600 degreesC assisted by air during 30 s. For 20 muL of soil extracts delivered to the atomizer and calibration by matrix matching, an analytical curve (10.0-100 mug of L-1) with good linear correlation (r = 0.999) between integrated absorbance and analyte concentration was established. The characteristic mass was similar to63 pg of Se, and the lifetime of the tube was similar to750 firings. The limit of detection was 1.6 mug L-1, and the relative standard deviations (n = 12) were typically <4% for a soil extract containing 50 mug of L-1. The accuracy of the determination of Se was checked for soil samples by means of addition/recovery tests. Recovery data of Se added to four enriched soil samples varied from 80 to 90% and indicated an accurate method.