56 resultados para Hand radiography

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of the present study was to optimize a radiographic technique for hand examinations using a computed radiography (CR) system and demonstrate the potential for dose reductions compared with clinically established technique. An exposure index was generated from the optimized technique to guide operators when imaging hands. Homogeneous and anthropomorphic phantoms that simulated a patient's hand were imaged using a CR system at various tube voltages and current settings (40-55 kVp, 1.25-2.8 mAs), including those used in clinical routines (50 kVp, 2.0 mAs) to obtain an optimized chart. The homogeneous phantom was used to assess objective parameters that are associated with image quality, including the signal difference-to-noise ratio (SdNR), which is used to define a figure of merit (FOM) in the optimization process. The anthropomorphic phantom was used to subjectively evaluate image quality using Visual Grading Analysis (VGA) that was performed by three experienced radiologists. The technique that had the best VGA score and highest FOM was considered the gold standard (GS) in the present study. Image quality, dose and the exposure index that are currently used in the clinical routine for hand examinations in our institution were compared with the GS technique. The effective dose reduction was 67.0%. Good image quality was obtained for both techniques, although the exposure indices were 1.60 and 2.39 for the GS and clinical routine, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The wrist and hand region has been the most commonly used for estimating age and osseous development due to the great number of ossification centers. The aim was to determine which method, Tanner & Whitehouse's (TW3), Greulich & Pyle's (GP) or Eklof & Ringertz's, more closely relates to the chronological age in subjects with Down syndrome with chronological ages between 61 and 180 months, using wrist and hand radiographs. The sample consisted of 85 radiographs, 52 of males and 33 of females. Eklof & Ringertz's method was computerized (Radiomemory). Greulich & Pyle's atlas was used and compared with the wrist and hand radiographs. For the TW3 method, 13 ossification centers were evaluated; for each one of them, there are seven or eight development stages to which scores are assigned; these scores are then added and the results are transformed into osseous age values. No statistically significant differences were observed between the male and female genders for methods TW3 and GP, contrasting with the observed differences for the Eklof & Ringertz method. Correlation (r2) between osseous and chronological ages was 0.8262 for TW3 and 0.7965 for GP, while for the method of Eklof & Ringertz, it was 0.7656 for females and 0.8353 for males. The author concluded that the osseous age assessment method that better related to the chronological age was the TW3, followed by Greulich & Pyle's and Eklof & Ringertz's.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Hand/wrist and dental radiographs are important for osteoporosis analysis in secondary hyperparathyroidism (SHPT). This study evaluated whether a correlation exists between the effects of the disease on the hands and jaws, and investigated the association between osteoporosis progression in the hands and parathyroid hormone (PTH) levels in chronic kidney disease (CKD) patients. Materials and methods: Four panoramic radiographic parameters (mental index, mandibular cortical index, trabecular bone pattern, and calcification/resorption) and four corresponding hand/wrist radiographic parameters (metacarpal cortical thickness, phalangeal cortical index, trabecular bone pattern, and calcification/resorption) were applied to investigate possible correlation between the effects of SHPT on the jaws and hands/wrists, by Spearman's correlation coefficient. PTH levels and the hand/wrist radiographic parameters were also tested by spearman's correlation coefficient (p < 0.05). The presence of brown tumors, vascular calcifications, and acroosteolysis on the hands was also evaluated. Results: Mandibular cortical index was strongly correlated with the phalangeal cortical index (p = 0.000). Phalangeal cortical index and trabecular bone pattern of hand/wrist correlated with PTH levels (0.002 and 0.000, respectively). Brown tumors occurred in four CKD patients, while both vascular calcifications and acroosteolysis were observed in 19 patients. Conclusion: There is a significant correlation between the morphological changes caused by secondary hyperparathyroidism in hand and jaw bones. The morphological status can be assessed using the mandibular cortical index, besides the phalangeal cortical index. The latter correlates well with parathyroid hormone levels of advanced chronic kidney disease. Clinical relevance: Panoramic images reveal morphological changes in the jaw bone, indicating likewise changes in the hand/wrist in severe secondary hyperparathyroidism. The severity of the bone changes may be a reflection of the parathyroid hormone levels in advanced chronic kidney disease. © 2012 Springer-Verlag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Digital radiography in the inspection of welded pipes to be installed under deep water offshore gas and oil pipelines, like a presalt in Brazil, in the paper has been investigated. The aim is to use digital radiography for nondestructive testing of welds as it is already in use in the medical, aerospace, security, automotive, and petrochemical sectors. Among the current options, the DDA (Digital Detector Array) is considered as one of the best solutions to replace industrial films, as well as to increase the sensitivity to reduce the inspection cycle time. This paper shows the results of this new technique, comparing it to radiography with industrial films systems. In this paper, 20 test specimens of longitudinal welded pipe joints, specially prepared with artificial defects like cracks, lack of fusion, lack of penetration, and porosities and slag inclusions with varying dimensions and in 06 different base metal wall thicknesses, were tested and a comparison of the techniques was made. These experiments verified the purposed rules for parameter definitions and selections to control the required digital radiographic image quality as described in the draft international standard ISO/DIS 10893-7. This draft is first standard establishing the parameters for digital radiography on weld seam of welded steel pipes for pressure purposes to be used on gas and oil pipelines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human injuries caused by South American porcupines (in Portuguese, ourico-cacheiro) are rare. This study reports severe hand injuries provoked by the body spines of the animal in a human and discusses the circumstances involved in the accident, with emphasis on environmental factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Accurate early diagnosis of lung metastases is important for establishing therapeutic measures. Therefore, the present study aimed to compare survey thoracic radiographs and computerized tomography (CT) scans to specifically identify lung metastases in female dogs with mammary tumors.Methods: Twenty-one female dogs, weighing 3 to 34 kg and aged from 5 years to 14 years and 10 months, with mammary tumors were studied. In all dogs before the imaging examinations, fine-needle aspiration cytology of the mammary tumors was performed to confirm the diagnosis. Three-view thoracic radiographs were accomplished: right lateral, left lateral and ventrodorsal views. Sequential transverse images of the thorax were acquired on a spiral Scanner, before and after intravenous bolus injection of nonionic iodine contrast. Soft-tissue and lung windows were applied. All the mammary tumors were surgically removed and examined histologically.Results: The correlation between the cytological and histological results regarding presence of malignancy was observed in only 17 cases. In radiographic examinations, no dog displayed signs of lung metastases or thorax chest lesions. CT detected lung metastasis in two cases, while small areas of lung atelectasis located peripherally were found in 28.57% of the dogs.Conclusion: In this study population, spiral CT showed higher sensitivity than chest radiographies to detect lung metastasis; this indicates that CT should be performed on all female dogs with malignant mammary tumors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present experimental study we assessed induced osteoarthritis data in rabbits, compared three diagnostic methods, i.e., radiography (XR), computed tomography (CT) and magnetic resonance imaging (MRI), and correlated the imaging findings with those obtained by macroscopic evaluation. Ten young female rabbits of the Norfolk breed were used. Seven rabbits had the right knee immobilized in extension for a period of 12 weeks (immobilized group), and three others did not have a limb immobilized and were maintained under the same conditions (control group). Alterations observed by XR, CT and MRI after the period of immobilization were osteophytes, osteochondral lesions, increase and decrease of joint space, all of them present both in the immobilized and non-immobilized contralateral limbs. However, a significantly higher score was obtained for the immobilized limbs (XT: P = 0.016, CT: P = 0.031, MRI: P = 0.0156). All imaging methods were able to detect osteoarthritis changes after the 12 weeks of immobilization. Macroscopic evaluation identified increased thickening of joint capsule, proliferative and connective tissue in the femoropatellar joint, and irregularities of articular cartilage, especially in immobilized knees. The differences among XR, CT and MRI were not statistically significant for the immobilized knees. However, MRI using a 0.5 Tesla scanner was statistically different from CT and XR for the non-immobilized contralateral knees. We conclude that the three methods detected osteoarthritis lesions in rabbit knees, but MRI was less sensitive than XR and CT in detecting lesions compatible with initial osteoarthritis. Since none of the techniques revealed all the lesions, it is important to use all methods to establish an accurate diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: the purpose of this in vivo study was to compare the accuracy of primary incisor length determined by direct digital radiography (straight-line measurement and grid superimposition) and measurement of the actual tooth length. Methods. Twenty-two primary maxillary incisors that required extractions were selected from 3- to 5-year-old children. The teeth were radiographed with an intraoral sensor using the long cone technique and a sensor holder (30-cm focus-to-sensor distance). The exposure time was 03 seconds. Tooth length was estimated by using straight-line and grid measurements provided by the distance measurement feature of the Computed Dental Radiography digital dental imaging system. The actual tooth length was obtained by measuring the extracted tooth with G digital caliper. Data were analyzed statistically by Pearson's correlation coefficient and a paired t test. Results: There were statistically significant differences (P=.007) between the 2 measurement techniques and between the actual tooth lengths and grid measurements. There was no statistically significant difference (P=38) between straight-line measurements and actual tooth lengths, showing that the straight-line measurements were more accurate. Underestimation of the actual tooth length, however, occurred in 45% of the straight-line measurements and in 73% of the grid measurements. Conclusion: It is possible to determine primary tooth length in digital radiographs using onscreen measurements with 0 reasonable degree of accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: the administration of cyclosporin A has been associated with significant bone loss and increased bone remodeling. The present investigation was designed to evaluate the effects of cyclosporin A on alveolar bone of rats subjected to experimental periodontitis, using serum, stereometric and radiographic analysis.Methods: Twenty-four rats were divided into one of the following groups with six animals each: group I, control rats; group II, in which the animals received a cotton ligature around the lower first molars; group III, in which the rats received a cotton ligature around the lower first molars and were treated with 10 mg/(kg body weight day) of cyclosporin A; group IV, in which the rats were treated with 10 mg/(kg body weight day) of cyclosporin A. At the end of experimental period, at 30 days, animals were killed and the serum calcium and alkaline phosphatase levels were measured in all groups. The distance from the alveolar bone crest to the cemento-enamel junction was measured radiographically for each mesial surface of the lower first molars of each rat. After histological processing, the stereological parameters: volume densities of multinucleated osteoclasts (V-o), alveolar bone (V-b), marrow (V-m), and relation of eroded surface/bone surface (Es/Bs) were assessed at the mesial region of the alveolar bone.Results: Significant decreases in serum calcium were observed in those groups that received cyclosporin A therapy. No significant changes in serum alkaline phosphatase were observed. The therapy with cyclosporin A combined with the ligature placement decreased the V-b and increased the V-o, V-m and Es/Bs at the mesial surface of lower first molars. on the other hand, the radiographic data showed that cyclosporin A therapy diminished the alveolar bone loss at the mesial surface of the lower first molars.Conclusions: Therefore, within the limits of this study, we suggest that cyclosporin A at immunosuppressive levels can bring about an imbalance in the alveolar bone homeostasis in rats. However, in the presence of inflammatory stimulation, the inhibition of the immune system by cyclosporin A may decrease the initial periodontal breakdown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The objective of this study was to evaluate the influence of homeopathic treatment with comfrey (Shymphytum officinalis 6CH) on radiographic bone density and area around titanium implants.Material and methods: Forty-eight rats were divided into two groups of 24 animals each: a control group (C) and a test group (SO). Each animal received one titanium micro-implant placed in the tibia. The animals in Group SO were subjected to 10 drops of comfrey 6CH per day mixed into their drinking water until the day of sacrifice. Eight animals of each group were sacrificed at 7, 14 and 28 days post-surgery, respectively.Standardized digital radiographs were obtained on the day of implant installation (baseline images) and on the day of sacrifice (final images). Digital subtraction of the two corresponding images was performed to evaluate changes in bone density and the area related to change around the implant between baseline and final images.Results: Subtraction images demonstrated that a significant difference existed in mean shade of gray at 14 days post-surgery between Group SO (mean 175.3 +/- 14.4) and Group C (mean 146.2 +/- 5.2). Regarding the area in pixels corresponding to the bone gain in Group SO, the differences observed between the sacrifice periods and groups were only significant at 7 days sacrifice between Group SO (mean 171.2 +/- 21.9) and Group C (mean 64.5 +/- 60.4).Conclusion: Within the limits of this study, comfrey administration promotes an increase in radiographic bone density around titanium implants in the initial period of bone healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The aim of this study was to detect the development of experimentally induced periapical lesions using conventional radiography and computed tomography.Study design. The root canals of dogs' teeth were exposed to the oral environment for 7 days for contamination and then sealed for 7 days (GI), 15 days (GII), 30 days (GIII), and 60 days (GIV). Immediately after each experimental period, radiographs and tomograms were taken in order to detect the occurrence of periapical bone resorption. The periapical radiographs were digitized and areas of bone resorption were measured using the VIXWIN 2000 software. Scores were assigned to the tomograms based on the progression of periapical bone resorption. The specimens were evaluated by calibrated examiners who were blinded to the groups. The radiographic results were analyzed by ANOVA and Tukey's test (P <.05) and the tomographic results were analyzed by Kruskal-Wallis and Dunn's tests (P <.05).Results. The radiographic evaluation did not reveal periapical lesions at the 7-day control. Lesions were radiographically visible at 15 and 30 days (47.4% and 77.8% of the cases, respectively) and presented similar dimensions (P <.05). At 60 days, lesions were detected in all specimens, presenting larger dimensions than those of the earlier evaluation periods (P <.05). The tomographic evaluation detected lesions at 7 and 15 days (32.5% and 83.3% of the cases, respectively). Lesions were detected in all specimens at the 30- and 60-day periods, when the greatest values of bone resorption were observed (P <.05).Conclusions. Tomography was able to detect periapical lesion development in its initial stages, even when the lesions were undetectable radiographically.