69 resultados para Guided missile industries

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new device was developed to hold linear transducers for transvaginal follicle aspiration. Efficacy of follicle aspiration was compared using a linear 6 MHz and a convex 5 MHz transducer. Fifty-five cows were submitted to follicle aspiration at random days of the estrous cycle. Aspirations were conducted with linear (n = 28) and convex (n = 38) transducers with 18 G needles at a negative pressure corresponding to 13 ml H2O/min. A greater number of follicles were aspirated using convex than to linear probe (12.4 versus 7.8, respectively, P < 0.05). Mean number of oocytes and recovery rates were similar for convex (5.4 and 48.6%) and linear (4.6 and 59.3%) transducers. Limited space between the linear transducer and needle guide restricted access to some portions of the ovary, reducing the number of follicles aspirated using a linear transducer. The newly developed adaptor allowed greater stability, holding the ovaries firmly against the linear transducer. This diminished mobility permitted a similar number of oocytes to be recovered with both transducers. In conclusion, this new adaptor provided a low cost alternative for routine follicle aspiration and oocyte recovery in cattle. (C) 2002 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the relationship between follicle size and oocyte recovery (OR) using ultrasound-guided follicle aspiration. Thirty Holstein cows were subjected to OR without gonadotrophic therapy. Oocytes were recovered two to four times from each cow in a total of 67 aspiration sessions, Ovarian follicles with diameters less than or equal to4 mm and >4 mm were aspirated in separated groups. Recovered oocytes from each group were kept separate and submitted to in vitro maturation, fertilization, and culture to the blastocyst stage. A total of 430 follicles were aspirated, of which 154 (35.8%) were from follicles >4 mm and 276 (64.2%) were from follicles less than or equal to4 mm. Seventy-seven oocytes (50%) were recovered from follicles >4 mm and 200 (72.2%) were from follicles less than or equal to4 mm. Nineteen blastocysts were obtained from follicles >4 mm, whereas 45 blastocysts were obtained from follicles less than or equal to4 mm. Recovery rate was greater (P < 0.01) in follicles less than or equal to4 mm, Oocyte quality, cleavage rate and blastocyst development did not differ between different follicle sizes. Routine aspiration of small follicles (less than or equal to4 mm) could increase the number of oocytes available for in vitro development. (C) 2001 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Having the objective of minimizing costs and improving their image in the consumer and export market, car battery industries began to seek environmental alternatives geared towards sustainable development. Reverse logistics flow represents an unprecedented tool for the economic and operational development of company activities, as well as a differential in the search for competitive advantages through environmentally correct practices. The aim of this paper is to describe the reverse logistics chain adopted by automotive battery industries in the midwest of the state of São Paulo, proposing a reverse logistics framework for small manufacturers that creates actions aimed at not harming the environment. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXTO E OBJETIVO: A biópsia da próstata não é um procedimento isento de riscos. Existe preocupação com respeito às complicações e quais seriam os melhores antibióticos usados antes do procedimento. O objetivo foi determinar a taxa de complicações e os possíveis fatores de risco para complicação na biópsia da próstata. TIPO DE ESTUDO E LOCAL: Estudo prospectivo clínico, realizado no Hospital das Clínicas de Botucatu. MÉTODOS: Foram realizadas biópsias em 174 pacientes que apresentavam anormalidade ao exame digital da próstata ou antígeno prostático específico maior que 4 ng/ml ou ambos. Todos os pacientes realizaram enema e antibioticoprofilaxia previamente ao exame. As complicações foram anotadas após o término do procedimento e em consultas posteriores. Algumas condições foram investigadas como possíveis fatores de risco para biópsias de próstata: idade, câncer da próstata, diabetes melito, hipertensão arterial sistêmica, antecedentes de prostatite, uso de ácido acetilsalicílico, volume prostático, número de biópsias e uso de sonda vesical. RESULTADOS: As complicações hemorrágicas foram mais comuns (75,3%) enquanto que as infecciosas ocorreram em 19% dos casos. O tipo mais freqüente foi a hematúria, ocorrendo em 56% dos pacientes. A infecção do trato urinário ocorreu em 16 pacientes (9,2%). Sepse foi observada em três pacientes (1,7%). Não houve óbitos. em 20% dos pacientes não foram observadas complicações após o exame. A presença da sonda vesical foi fator de risco para complicações infecciosas (p < 0,05). O número maior de amostras nas biópsias foi relacionado à hematúria, sangramento retal e complicações infecciosas (p < 0,05). As demais condições investigadas não se relacionaram com complicações pós-biópsia da próstata. CONCLUSÕES: As complicações pós-biópsia da próstata foram em sua maioria autolimitadas. A taxa de complicações graves foi baixa, sendo a biópsia de próstata guiada pelo ultra-som segura e eficaz. A retirada de um maior número de fragmentos na biópsia relaciona-se com hematúria, sangramento retal e complicações infecciosas. A sonda vesical foi um fator de risco para complicações infecciosas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Barrier materials as cellulose membranes are used for guided tissue repair. However, it is essential that the surrounding tissues accept the device. The present study histologically evaluated tissue reaction to a microbial cellulose membrane after subcutaneous implantation in mice. Furthermore, the interaction between mesenchymal stem cells and the biomaterial was studied in vitro to evaluate its ability to act as cellular scaffold for tissue engineering.Methods: Twenty-five Swiss Albino mice were used. A 10 x 10 mm cellulose membrane obtained through biosynthesis using Acetobacter xylinum bacteria was implanted into the lumbar subcutaneous tissue of each mouse. The mice were euthanatized at seven, 15, 30, 60, and 90 days, and the membrane and surrounding tissues were collected and examined by histology.Results: A mild inflammatory response without foreign body reaction was observed until 30 days post-surgery around the implanted membrane. Polarized microscopy revealed that the membrane remained intact at all evaluation points. Scanning electron microscopy of the cellulose membrane surface showed absence of pores. The in vitro evaluation of the interaction between cells and biomaterial was performed through viability staining analysis of the cells over the biomaterial, which showed that 95% of the mesenchymal stem cells aggregating to the cellulose membrane were alive and that 5% were necrotic. Scanning electron microscopy showed mesenchymal stem cells with normal morphology and attached to the cellulose membrane surface.Conclusion: The microbial cellulose membrane evaluated was found to be nonresorbable, induced a mild inflammatory response and may prove useful as a scaffold for mesenchymal stem cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computed tomographic scanning is a precise, noinvasive surveying technique that enables the professionals to improve the precision of implant placement by building a prototype that allows the confection of surgical guides. The authors present a clinical case of anterior tooth rehabilitation with frozen homogenous bone graft and immediately loaded titanium implant using computer-guided surgery. A multislice computed tomography was realized, and a prototype was built. All the procedures were previously realized in the prototype before started in the patient. This technique allows a better surgical planning, makes the procedures more accurate, and reduces surgery time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ameloblastoma is a true neoplasm of odontogenic epithelial origin. It is a slow-growing benign tumor of the jaw, and patients usually present late after the tumor achieves considerable size to cause facial disfigurement. Diagnosis mainly from tissue biopsy and radiograph findings does assist in differentiating between types of ameloblastoma. Unicystic ameloblastoma is a tumor with a strong propensity for recurrence. There is a difference in biological behavior between mural unicystic ameloblastoma and those which are simply cystic or show intraluminal proliferation. The challenges in the management of this tumor are to provide complete excision in addition to reconstructing the bony defect, to provide the patient with reasonable cosmetic and functional outcome. The authors report a case of a mural unicystic ameloblastoma in a 23-year-old man who was treated by partial resection of the mandible. Biomedical prototypes were used because they provide acceptable precision and are useful for treatment planning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to conduct a critical literature review about the technique of computer-guided surgery in implantology to highlight the indications, purposes, immediate loading of implants and complications, protocol of fabrication, and functioning of virtual planning software. This literature review was based on OLDMEDLINE and MEDLINE databases from 2002 to 2010 using the key words "computer-guided surgery" and "implant-supported prosthesis." Thirty-four studies regarding this topic were found. According to the literature review, it was concluded that the computer-assisted surgery is an excellent treatment alternative for patients with appropriate bone quantity for implant insertion in complete and partially edentulous arches. The Procera Nobel Guide software (Nobel Biocare) was the most common software used by the authors. In addition, the flapless surgery is advantageous for positioning of implants but with accurate indication. Although the computer-guided surgery may be helpful for virtual planning of cases with severe bone resorption, the conventional surgical technique is more appropriate. The surgical guide is important for insertion of the implants regardless of the surgical technique, and the success of immediate loading after computer-guided surgery depends on the accuracy of clinical and/or laboratorial steps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the effect of lethal photosensitization and guided bone regeneration (GBR) on the treatment of ligature-induced peri-implantitis in different implant surfaces. The treatment outcome was evaluated by clinical and histometric methods. A total of 40 dental implants with four different surface coatings (10 commercially pure titanium surface (cpTi); 10 titanium plasma-sprayed (TPS); 10 acid-etched surface; 10 surface-oxide sandblasted) were inserted into five mongrel dogs. After 3 months, the animals with ligature-induced peri-implantitis were subjected to surgical treatment using a split-mouth design. The controls were treated by debridment and GBR, while the test side received an additional therapy with photosensitization, using a GaAlAs diode laser, with a wavelength of 830 nm and a power output of 50 mW for 80 s (4 J/cm(2)), and sensitized toluidine blue O (100 mu g/ml). The animals were sacrificed 5 months after therapy. The control sites presented an earlier exposition of the membranes on all coating surfaces, while the test group presented a higher bone height gain. Re-osseointegration ranged between 41.9% for the cpTi surface and 31.19% for the TPS surface in the test sites; however differences were not achieved between the surfaces. The lethal photosensitization associated with GBR allowed for better re-osseointegration at the area adjacent to the peri-implant defect regardless of the implant surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The aim of this study was to evaluate the use of a collagen-based membrane compared with no treatment on guided bone regeneration by 3-dimensional computerized microtomography (mu CT).Study Design. Defects were created between the mesial and distal premolar roots of the second and third premolars (beagle dogs; n = 8). A collagen-based membrane (Vitala; Osteogenics Biomedical Inc., TX, USA) was placed in one of the defects (membrane group; n = 16), and the other was left untreated (no-membrane group; n = 16). Left and right sides provided healing samples for 2 and 16 weeks. Three-dimensional bone architecture was acquired by mu CT and categorized as fully regenerated (F, bone height and width) or nonregenerated (N).Results. Chi-square tests (95% level of significance) showed that tooth did not have an effect on outcome (P = .5). Significantly higher F outcomes were observed at 16 weeks than 2 weeks (P = .008) and in membrane group than in no-membrane group (P = .008).Conclusions. The collagen-based membrane influenced bone regeneration at the furcation. (Oral Surg Oral Med Oral Pathol Oral Radiol 2012;114:437-443)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to research a membrane material for use in guided bone regeneration. Study design: In this study, 25 male Wistar rats were used to analyze the biocompatibility and degradation process of biomembranes. The morphological changes in subcutaneous implantations were assessed after 7, 14, 21, 28 and 70 days. The materials were made of polyurethane polymer (AUG) obtained from vegetal oil (Ricinus communis) and polytetrafluoroethylene membrane (PTFE). The surface characteristics of the physical barriers in scanning electronic microscopic (SEM) were also evaluated. Results: In both groups, the initial histological analysis showed moderate inflammatory infiltrate, which was predominantly polymorphonuclear. There was also a presence of edema, which was gradually replaced by granulation tissue, culminating in a fibrous capsule. In the AUG group, some multinucleated giant cells were present in the contact interface, with the space previously occupied by the material. However, membrane degradation was not observed during the period studied. According to the present SEM findings, porosity was not detected in the AUG or PTFE membranes. Conclusion: The researched material is biocompatible and the degradation process is extremely slow or may not even occur at all.