4 resultados para Glenoid cavith

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: We aimed to establish values and parameters using multislice reconstruction in axial computerized tomography (CT) in order to quantify the erosion of the glenoid cavity in cases of shoulder instability. Methods: We studied two groups using CT. Group I had normal subjects and Group II had patients with shoulder instability. We measured values of the vertical segment, the superior horizontal, medial and inferior segments, and also calculated the ratio of the horizontal superior and inferior segments of the glenoid cavity in both normal subjects and those with shoulder instability. These variables were recorded during arthroscopy for cases with shoulder instability. Results: The mean values were 40.87 mm, 17.86 mm, 26.50 mm, 22.86 mm and 0.79 for vertical segment, the superior horizontal, medial and inferior segments, and the ratio between horizontal superior and inferior segments of the glenoid cavity respectively, in normal subjects. For subjects with unstable shoulders the mean values were 37.33 mm, 20.83 mm, 23.07 mm and 0.91 respectively. Arthroscopic measurements yielded an inferior segment value of 24.48 mm with a loss of 2.39 mm (17.57%). The ratio between the superior and inferior segments of the glenoid cavity was 0.79. This value can be used as a normative value for evaluating degree of erosion of the anterior border of the glenoid cavity. However, values found using CT should not be used on a comparative basis with values found during arthroscopy. Conclusions: Computerized tomographic measurements of the glenoid cavity yielded reliable values consistent with those in the literature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fixed mandibular propulsion appliances are an alternative for the treatment of Class II malocclusion in individuals with mandibular deficiency. Since they are fixed appliances, said devices keep the mandible in an anterior-forced position during rest and during all mandibular functions. When a propulsive appliance is used, the lower jaw is displaced forward and downward. This movement leads to a new position of the condyle, which can, ultimately affect the normal functioning of the temporomandibular joint (TMJ). The aim of this paper was to review effects of fixed mandibular propulsive appliance on TMJ. Inclusion criteria considered studies on animals or humans using TMJ radiography, computed tomography, and magnetic resonance imaging. Studies confirm a favorable relation between condyle and glenoid fossa following treatment with fixed mandibular propulsion appliances.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)