264 resultados para Gerenciamento eletrônico de instalações elétricas

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Are presented on this paper, concepts of corrective, preventive and predictive maintenances, following the prerequisites for planning and implementation of a maintenance plan. You also find the theoretical introduction of some measurement instruments accompanied by the necessary and recommended activities during routine maintenances of the electrical equipments in a building installation. Using case study, it is possible to assess a real maintenance plan applied to two occupied floors in a financial institution. The developing of a case study consolidates the effectiveness of the present concepts on this theoretical introduction and shows that the current maintenance plan can be improved in order to obtain better results on company productivity and reliability of equipments. As a conclusion, we can notice the importance of a solid maintenance plan and the need of including this theme on the graduation in Electrical Engineering

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper addresses methods of reducing the electric energy consumption on residences by the means of constructive measures and replacement of electric devices. Analyzing their impacts on residential and national level based on data issued by IBGE (Brazilian Institute of Geography and Statistics) and PROCEL (National Program for Electricity Conservation).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrical installations in industries involving high currents and voltages considered. On the other side is the common appearance of electrical failures, caused by human error, defects in electrical equipment or electrical installation aging itself. These failures are varied, those with the highest rate of occurrence and cause much damage to electrical installations, are overcurrent and overvoltage. Therefore there is a need to project a system that can detect and minimize possible effects caused by faults in electrical installations industries. Protection systems in electric industries emerge as an alternative to control especially voltage and current magnitudes. Engineered based on the functions of the relays, protection systems are an indispensable tool for any industrial substation. But the project of such systems becomes increasingly more complex, due to technological development. Electrical equipment not develop at the same speed that the protective devices (relays), making it indispensable knowledge of integration of technologies

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Through awareness of new trends of consumption of the population with regard to housing, comfort, entertainment, security and sustainability, it was crafted a work that set out to study and develop the concept of home automation and how it will revolutionize the electrical installation projects and energy savings. A pre-wiring project, taking into account, basically, the installed load, is presented as a basis for comparison. The protocols for communication between intelligent devices in an automation environment, used in the work, are the X-10, LonWorks and UPnP. The home network is studied and divided into subsystems, for a better understanding, which are the lighting, audio, video and multimedia system, security, air conditioning and central vacuum system, and the idea of integrated design and system integrator is introduced, showing the change necessity in the design philosophy of electrical installations. The main means of energy savings in an automated home, such as dimerization, master off and smart meters are presented and, finally, it was concluded that there is a need to structure electrical installation projects more comprehensive with regard to home automation, in order to become more efficient and useful to users

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia de Produção - FEG

Relevância:

40.00% 40.00%

Publicador:

Resumo:

After the discovery of ionizing radiation, its applications in various fields of science began to take significant proportions. In the case of medicine, there are the application areas in radiotherapy, diagnostic radiology and nuclear medicine. It was then necessary to create the field of radiological protection to establish the conditions necessary for the safe use of such ionizing radiation. Apply knowledge obtained during the graduation stage and in the practice of radiological protection in the areas of nuclear medicine and diagnostic radiology. In the area of nuclear medicine, tests were made in the Geiger-Muller counters (GM) and the dose calibrator (curiometer), the monitoring tests of radiation, waste management, clean of the Therapeutic room and testing the quality control of gamma-chambers. In the area of radiology, were performed tests of quality control equipment for conventional X-ray equipment and x-ray fluoroscopy, all following the rules of the National Health Surveillance Agency (ANVISA), and reporting of tests. The routine developed in the fields of nuclear medicine in hospitals has proved very useful, since the quality control of GM counters contribute to the values of possible contamination are more reliable. The control of dose calibrator enables the patient not to receive different doses of the recommended amounts, which prevents the repetition of tests and unnecessary exposure to radiation. The management of waste following the rules and laws established and required for its management. Tests for quality control of gamma chambers help to evaluate its medical performance through image. In part of diagnostic radiology, tests for quality control are performed in order to verify that the equipment is acceptable for usage or if repairs are needed. The knowledge acquired at the internship consolidated the learning of graduation course

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Health care waste (HCW) is the type of waste that results from activities performed in health care services during care provision to humans or animals. Presently, according to RDC 306/04, issued in 2004 by Anvisa, and Resolution no. 358/05, by CONAMA, waste groups have the following classification: Group A (biological waste), Group B (chemical waste), Group C (waste containing radionucleotides), Group D (common waste) and Group E (piercing and cutting waste). In Brazil, 149 tons of wastes are collected every day, and HCW corresponds to approximately 1% to 3 % of that total. An efficient way to adequately manage HCW is through the Health Care Waste Management Plan (HCWMP), and it is possible to reduce the risk posed by certain materials in addition to ensuring disposal in an ecologically correct and economical fashion. According to the Pan-American Health Organization (PAHO), the management process enables health care establishments to adequately manage waste. Hence, there is greater control and reduction in the health risks caused by infectious or special waste, in addition to facilitated recycling, treatment, storage, transport and final disposal of solid hospital waste in an environmentally safe fashion. To evaluate the management of HCW of Groups A and D from the Intensive Care Unit of the University Emergency Hospital - FMB - UNESP in the city of Botucatu according to the guidelines presently in force. The waste flow was followed up, and during four random days in the month of September 2011, waste was quantified by estimating daily and monthly values, according to its classification. : In 2011, the University hospital has produced an average of 57,676.8 kg/month of biological and common waste. By adding Groups A and D, during the four days, approximately 209.8 Kg of waste (202.2 Kg of Group A and 7.6 Kg of Group D) were produced in the establishment under study, which... (Complete abstract click electronic access below)