12 resultados para Gage

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development of a semiconductor strain gage tactile transducer. It was designed with the goal of measuring finger forces without affecting the hand dexterity. The transducer structure was manufactured with stainless steel and has small dimensions ( 4 min diameter and I min thickness). It is light and suitable to connect to the finger pads. It has a device that prevents its damage when forces are applied. The semiconductor strain gage was used over due its small size and high sensitivity, although it has high temperature sensitivity. Theory, design and construction details are presented the signal conditioning circuit is very simple because the semiconductor strain gage sensitivity is high. It presents linear response from 0 to 100 N, 0.5 N resolution, fall time of 7.2 ms, good repeatability, and small hysteresis. The semiconductor strain gage transducer has characteristics that can make it very useful in Rehabilitation Engineering, Robotics, and Medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a high senstivity low cost capacitive strain gage sensor. The theory, design, and sensor construction details are presented. It consists of eight capacitive sensors connected in two full bridges. The capacitive strain gage sensor structure was designed in order to produce high sensitivity and low dependence with temperature. By using a simple signal conditioning circuit constituted by a differential amplifier, a band-pass filter, and a precision rectifier the device can measure forces with resolution of 0.009 N and precision of 98.7%. It is rugged, presents linear response, and good repeatability. It presents sensitivity of 8.7 V/N and fall time of 12 ms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aboveground biomass predictive equations were developed for a highly productive 47-year-old mixed Douglas-fir and western hemlock stand in southwest Washington State to characterize the preharvest stand attributes for the Fall River Long-Term Site Productivity Study. The equations were developed using detailed biomass data taken from 31 Douglas-fir and 11 western hemlock trees within the original stand. The stand had an average of 615 live trees per hectare, with an average dbh of 35.6 cm (39.1 cm for Douglas-fir and 33.3 cm for western hemlock) and an average total tree height of 31.6 m (32.8 m for Douglas-fir and 30.2 m for western hemlock). Equations developed were of the form In Y = b(1) + b(2) In dbh, where Y = biomass in kg, dbh = diameter in cm at 1.3 m height, b(1) = intercept, and b(2) = slope of equation. Each tree part was estimated separately and also combined into total aboveground biomass. The total aboveground biomass estimation equations were In Y = -0.9950 + 2.0765 In dbh for Douglas-fir, and In Y = -1.6612 + 2.2321 In dbh for western hemlock. The estimate of the aboveground live-free biomass was of 395 Mg ha(-1) (235 Mg ha(-1) for Douglas-fir and 160 Mg ha(-1) for western hemlock), with 9.5, 29.3, 12.9, 308, and 32.7 Mg ha(-1) in the foliage, live branches, dead branches, stem wood, and stem hark, respectively. When compared with biomass estimates from six other studies, ranging in age from 22 to 110 years and from 96.3 to 636 Mg ha(-1), the biomass of the Fall River site was relatively high for its age, indicating very high productivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a strain gauge-based sensor used for measuring finger force. The theory, design, and sensor construction details are presented. It was constructed using metallic strain gauges and a carefully designed structure which has a protection de-vice that impedes the sensor damage when forces higher than 100 N are applied. Its dimensions are suitable for measuring thumb force, but the same design can be used for constructing smaller sensors for other fingers. It is rugged, presents linear response, good repeatability, resolution of 0.3 N, low hysteresis, and sensitivity of 0.12 V/N. It can be useful in rehabilitation engineering, biomechanics, robotics, and medicine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aerodynamic balances are employed in wind tunnels to estimate the forces and moments acting on the model under test. This paper proposes a methodology for the assessment of uncertainty in the calibration of an internal multi-component aerodynamic balance. In order to obtain a suitable model to provide aerodynamic loads from the balance sensor responses, a calibration is performed prior to the tests by applying known weights to the balance. A multivariate polynomial fitting by the least squares method is used to interpolate the calibration data points. The uncertainties of both the applied loads and the readings of the sensors are considered in the regression. The data reduction includes the estimation of the calibration coefficients, the predicted values of the load components and their corresponding uncertainties, as well as the goodness of fit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O mieloma múltiplo (MM) é uma neoplasia maligna secundária à expansão clonal de células plasmáticas caracterizada pela presença de imunoglobulina monoclonal no sangue e/ou na urina, lesões líticas ósseas e infiltração de plasmócitos monoclonais na medula óssea. A caracterização dos mecanismos responsáveis pela expansão das células tumorais do MM é difícil e envolve uma série de alterações genéticas e mudanças no microambiente da medula óssea, favorecendo o crescimento do tumor e a falha do sistema imune em reconhecê-lo. O MM é uma doença incurável, sendo a sobrevida mediana dos pacientes em torno de 3-5 anos. Terapias atuais como quimioterapia e transplante autólogo de células-tronco podem induzir remissão da doença, mas a recaída e a morte são inevitáveis. Os antígenos específicos câncer/testículo (CTs) foram originalmente descritos em pacientes com melanoma e são assim denominados, pois suas proteínas foram identificadas em espermatogônias, células conhecidas por não expressarem antígenos de histocompatibilidade (HLA), o que as impossibilita de desencadear uma resposta imune específica. Esses antígenos foram identificados posteriormente em vários tipos de tumores humanos, como melanoma, carcinoma pulmonar, câncer renal, entre outros. Até o momento, existem poucas informações a respeito de sua importância como fatores de prognóstico clínico ou relacionado à proliferação aberrante das células plasmáticas. Assim, o objetivo deste estudo é avaliar o nível de expressão gênica dos antígenos câncer/testículo MAGEC1(CT7), MAGEA3/6, LAGE-1, NY-ESO-1 e GAGE em amostras de aspirado de medula óssea total de pacientes com mieloma múltiplo. A análise de expressão por RT-PCR dos 5 CTs de interesse, realizada em 21 amostras de medula total de pacientes com MM, demonstrou as seguintes freqüências: CT7 (42,9%), LAGE-1 (23,8%)... (Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work aims to study the possible causes of cracks founded and recovered in translation cars of ore Forklift / ore Reclaimer. To identify the possible causes of cracks observed on the equipment it was used a static approach analysis, using a finite element method as an analysis tool, using a specific structural analysis program. After making the model, a strain gage measurement was necessary because there may be significant amounts of masses of non-structural components that were not modeled and were not available in the drawings, as well as fouling ore. With the calibrated model it was processed analyses with the load cases of dead load, product, wind and excavation. After the processing, it was observed that none of these load cases resulted in values that caused the crack, so another three hypotheses were tested: depression and misalignment, jacking and translation of only three cars. Of these three hypotheses it was observed that the jacking coud be the cause of the cracks, because the distribution of stress. Due to the miss of parameters, like the height utilized in this process, it was not possible to affirm the real stress level