282 resultados para Fuso meiótico
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Objective: To investigate the relationship between the presence of meiotic spindle in human oocytes and fertilization rates in ICSI cycles. Methods: Search strategies included online surveys of databases from 1990 to 2008. Nine trials fulfilled the inclusion criteria Results: According to the meta-analysis, the results showed statistically significant higher fertilization rate (p<0.0001) when the meiotic spindle was viewed than when it was not. There was heterogeneity in this comparison. Conclusion: The presence of a birefringent meiotic spindle in human oocytes can predict a higher fertilization rate. This observation has clinical relevance mainly in countries where there is a legal limit on the number of oocytes to be fertilized. Copyright - SBRA - Sociedade Brasileira de Reprodução Assistida.
Resumo:
Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB
Resumo:
Placa e espaçador de polímero derivado do óleo de mamona (PDOM) (Ricinus communis) foram avaliados clínica, radiográfica e histologicamente na tração linear, fixação e fusão vertebral cervical em 20 cães adultos, sem raça definida, pesando entre 17 e 22kg. Foram sacrificados quatro animais aos 10, 30, 60, 90 e 120 dias de pós-operatório. Após exposição da coluna cervical, por acesso ventral, o disco intervertebral de C4-C5 foi fenestrado e a abordagem ao canal medular foi feita por meio de fenda óssea. Um espaçador de PDOM foi colocado preenchendo o defeito ósseo. Os corpos vertebrais C4-C5 foram fixados com placa do mesmo material, utilizando-se dois parafusos corticais em cada corpo vertebral. Apenas um animal apresentou déficit neurológico no pós-operatório imediato. Radiograficamente as vértebras mostravam-se normais e alinhadas, sem colapso do espaço intervertebral, porém não houve neoformação óssea entre as vértebras. Ao exame mielográfico, não houve compressão da medula espinhal. Os implantes foram efetivos em manter a tração linear e fixação das vértebras cervicais e não ocorreu a fusão vertebral.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Barreto R.S.N., Miglino M.A., Meirelles F.V., Visintin J.A., Silva S.M., Burioli K.C., Fonseca R., Bertan C., Assis Neto A.C. & Pereira F.T.V. 2009. [Characterization of the caruncular fusion in gestations of natural and cloned bovine conceptuses.] Caracterizacao da fusao caruncular ern gestacoes naturais e de conceptos bovinos clonados. Pesquisa Veterinaria Brasileira 29(10):779-787. Laboratorio de Morfofisiologia da Placenta e Embriao, Faculdade de Zootecnia, Universidade Estadual Paulista, SP294 Km 651, Dracena, SP 17900-000, Brazil. E-mail: fverechia@dracena.unesp.brThe objective of the study was to compare the characteristics of the caruncular fusion in gestations of non-cloned and cloned conceptuses. The non-cloned conceptuses were divided according to the gestation period: Group 1 (2 to 3 months; n=9),II (4 to 6; n=9); III (7 to 8; n=10) and IV (9 n=7). The cloned conceptuses formed the Group V: 9 months; n=4. The caruncles were observed macroscopically (number and dimensions: length, width and height), microscopically and submitted to statistical analysis (5% of significance). We observed three types of macroscopic caruncular fusions: oval (morphologically normal); two united adjacent caruncles and the lobulated type, characterized by regions with several united caruncles presenting a false fusion or deformation of the caruncular parenchyma. The length of the caruncles was 1.55 +/- 0.57; 2.45 +/- 0.55; 4.66 +/- 2.0 and 5.72 +/- 1.90cm for the groups 1, 11, 111, IV respectively. As for the height, the caruncles presented a lineal growth during the gestation: 0.40 +/- 0.15; 0.57 +/- 0.21; 1.0 +/- 0.48 and 1.80 +/- 0.91cm, for the respective groups 1, 11, 111 and IV. The width of the caruncles was similar between the groups I and 11 (0.97 +/- 0.30 e 1.42 +/- 0.71 cm) and the groups III and IV (2.68 +/- 1.22 and 3.52 +/- 1.16cm). When the group V was compared to the IV, the caruncles of the group V presented a larger length (5.72 +/- 1.90 vs. 7.88 +/-.13cm) and width (3.52 +/- 1.16 vs. 4.93 +/- 1.46cm), however they were similar in height (1.80 +/- 0.91 and 2.25 +/- 0.67cm). We verified that in gestations of cloned conceptuses the caruncles presented a larger development than in gestations of non-cloned conceptuses. The fusioned caruncles presented measurements statistically similar to the isolated ones in all the parameters and groups. Under light microscopy, we observed the formation of a stromal axis from the basis of the caruncle to the apex of the fusional fissure, with the histological constitution similar to the endometrial stroma. Three microscopic shapes were also unpublished defined: true fusion with a single axis evident below the fusional fissure; pseudofusion with a double axis in H shape and false fusion with absence of the axis. The first two formats were associated to the oval and lobulated caruncles and the last one to the false fusion with deformation of the caruncle parenchyma. The fusional axis increased in size along the gestation among the groups I, II, III and IV. The group V presented a larger length and width of the axis when compared to the group IV. Thus, in gestations of cloned conceptuses a destruction of the lateral epithelium of the caruncles is associated to an incompetence in the maternal-fetal interdigitation, that compromises the cotyledonary fusion. We suggest that, in gestations derived of cloned conceptuses, the increase of the size of the caruncular fusions is possibly associated to a compensatory mechanism for the metabolic exchanges between mother and fetus, in reason of the smallest number of isolated caruncles.
Resumo:
Being the surface roughness a fundamental property in the fit of the castings, it was determined the roughness of 5 high-copper casting alloys, according to the heating over their melting temperature. That way, the specimens made with smooth plastic in the shape of a rectangular plate, 2 mm x 7 mm x 11 mm were invested into a cristobalite investment. After heating and elimination on the plastic, the molds were filled by 3 g of molten alloy, casted in a electrical casting machine at the casting temperature at 25 degrees C and 50 degrees C overheating. The surface roughness was measured in a roughness analyser, Talysurf. As a result, it was verified that there is a variation of surface roughness among the alloys tested, and the heating of the alloys until 50 degrees C over the melting temperature does not interfere in the roughness.
Resumo:
It was evaluated the castability of four copper-aluminium alloy according the melting casting method used. The specimens were made using polyester mesh screen, with 11 x 11 filaments of 0.26 mm thick, fixed along of two adjacent edges in wax bar, with the sprue attached at their junction. The alloys were in an electrical casting machine and a centrifugal casting machine with an air/gas torch. The castability values were obtained by the percentage of completed segments of the resulting cast alloy screen. It was verified that the use of the electrical casting machine produced higher castability values to the copper-aluminium alloys than those produced by a centrifugal casting machine with an air/gas torch.
Resumo:
It was evaluated the Vickers hardness of five high-copper casting alloys, in their original package form and after casting, according to the casting method used. That way, ten ingots, supplied by the manufacturers of each alloy, were included in self-curing acrylic resin, polished, numerated and submitted to Vickers hardness test at load of 200 g during 30 seconds. Afterwards the numerated ingots were removed from the acrylic resin and five of those were cast in an electrical casting machine and the other five in a centrifugal casting machine with an air/gas torch. The specimens obtained were included in self-curing acrylic resin, polished and submitted to Vickers hardness test. As a result it was verified that there is a variation of hardness among the alloys tested, and the use of the electrical casting machine produced lower hardness values than those produced when used the centrifugal casting machine with an air/gas torch. Also, there is a decrease of hardness of the cast alloys when they are tested in their original form and after casting.
Resumo:
The authors looked for the verification of the fatigue of retentive clasps utilized on the removable partial denture. According to this, it was idealized and built on assay machine, that through movements, simulate the insertion and removal of the clasp for a pattern tooth, manufactured on cobalt-chromium which has all the preparation normally utilized to the correct confection of this type of prosthesis. It was utilized three different commercial alloys based on cobalt-chromium: L1-Biosil; L2-Steldent; L3-Duracron. It was utilized the T clasp of Roach, with was tested upon three different proportions among width and thickness: E1-1.7;E2-2.0 and E3-2.3 and was casted through two casting techniques: F1-oxygen-gas and F2-oxygen-acetylene. The clasps were tested on the machine, which allowed the reading of the number of insertion and removal cycles made until fatigue appeared. The obtained results were submitted to the statistic analysis and the authors concluded that: a) L3 (Duracrom) obtained the best results followed by L1 (Biosil) and finally L3 (Steldent); b) among the analyzed thickness, the best results were obtained by E3, followed by E2 and after this E1; c) form the casting techniques, F2 gave us the best results.
Resumo:
The authors tested the T clasp of Roach in three differents proportions among width and thickness: E1-1.7; E2-2.0 and E3-2.3, with a constant length of 15 mm. These clasps were casted with three cobalt-chromium alloys (L1-Biosil; L2-Steldent and L3-Duracrom), through two casting techniques (F1-oxygen-gas and F2-oxygen-acetylene). The fatigue of the clasps were verified by using and assay machine, that through movements, simulate the insertion and removal of the clasps for a pattern which were obtained from a premolar, prepared in a surveyor. This machine detect the fatigue of the clasps and count the number of cycles of insertion and removal realized. The obtained results of the interaction between the analysed factors, were submitted to the statistic analysis and the authors concluded that: a) the interaction of factors, Alloy x Thickness, Alloy x Casting Technique and Thickness x Casting Technique did not change the order of effects that the factors showed separately but gave rise to effects of different magnitude for any observed sense; b) the simultaneous interaction of the factors Alloy x Thickness x Casting Technique confirmed the superiority of the L3 alloy, the thickness E3 and the F2 casting technique.
Resumo:
This study aims to evaluate safety and effectiveness of the use of orthesis in postoperative degenerative disorders of the cervical spine. Although widely used, there are not defined criteria for the use of cervical collars, and their importance on cervical arthrodesis. A systematic literature review was undertaken and a multicentre controlled clinical trial comprising 32 specialized services, with a total of 257 patients who met the inclusion criteria of the review. Clinical and radiographic outcomes were compared in post surgical patients that used or not rigid cervical collar during 6 to 12 weeks after surgery. The evidence available on literature, although weak, suggests that cervical collar decreases the clinical scores in first weeks after surgery. Furthermore, it does not alter the rate of fusion when used concomitantly with plaque and screws through anterior access in cervical degenerative diseases on a single anatomical level.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
Pós-graduação em Ciências Odontológicas - FOAR