34 resultados para Flow function
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This paper presents a new approach to solve the Optimal Power Flow problem. This approach considers the application of logarithmic barrier method to voltage magnitude and tap-changing transformer variables and the other constraints are treated by augmented Lagrangian method. Numerical test results are presented, showing the effective performance of this algorithm. (C) 2005 Elsevier Ltd. All rights reserved.
Resumo:
This paper presents a new algorithm for optimal power flow problem. The algorithm is based on Newton's method which it works with an Augmented Lagrangian function associated with the original problem. The function aggregates all the equality and inequality constraints and is solved using the modified-Newton method. The test results have shown the effectiveness of the approach using the IEEE 30 and 638 bus systems.
Resumo:
A numerical scheme based on the Finite Element Method (FEM) is presented to calculate the full solution of a three-dimensional steady magnetohydrodynamic (MHD) flow with moderately high Hartmann numbers and interaction parameters. An incompressible, viscous and electrically conducting liquid-metal is considered. Assuming a low magnetic Reynolds number, the solution method solves the coupled Navier-Stokes and Maxwell's equations through the use of a penalty function method. Results are presented for Hartmann numbers in the range 10(2)-10(3).
Resumo:
This paper describes a new methodology adopted for urban traffic stream optimization. By using Petri net analysis as fitness function of a Genetic Algorithm, an entire urban road network is controlled in real time. With the advent of new technologies that have been published, particularly focusing on communications among vehicles and roads infrastructures, we consider that vehicles can provide their positions and their destinations to a central server so that it is able to calculate the best route for one of them. Our tests concentrate on comparisons between the proposed approach and other algorithms that are currently used for the same purpose, being possible to conclude that our algorithm optimizes traffic in a relevant manner.
Resumo:
This study assessed the effects of a single intracoronary injection of autologous stem cells on the cardiac function of dogs with Chagas cardiomyopathy. Bone-marrow-derived stem cells were delivered into the right and left coronary arteries of 5 mature dogs with mildly compromised cardiac function due to chronic Chagas cardiomyopathy. Blood pressure and electrocardiographic and echocardiographic parameters were recorded at monthly intervals for 6 mo in the 3 dogs that survived. Although no changes were observed in the electrocardiogram and blood pressure, there was a significant increase in peak velocity of aortic flow 3 mo after stem cell transplantation. Pre-ejection period, isovolumic relaxation time, and the Tei index of myocardial performance were reduced significantly 4 mo after the procedure. All significant changes persisted to the end of the study. The results suggest that the transplantation of autologous bone-marrow-derived stem cells into the coronary arteries of dogs with Chagas cardiomyopathy may have a beneficial effect but the small number of dogs studied was a limitation.
Resumo:
The effects of adrenergic stimulation on mean circulatory filling pressure (MCFP), central venous pressure (P-CV) and stroke volume (Vs), as well as the effects of altered MCFP through changes of blood volume were investigated in rattlesnakes (Crotalus durissus). MCFP is an estimate of the upstream pressure driving blood towards the heart and is determined by blood volume and the activity of the smooth muscle cells in the veins (venous tone). MCFP can be determined as the plateau in P-CV during a total occlusion of blood flow from the heart.Vs decreased significantly when MCFP was lowered by reducing blood volume in anaesthetised snakes, whereas increased MCFP through infusion of blood (up to 3 ml kg(-1)) only led to a small rise in Vs. Thus, it seems that end-diastolic volume is not affected by an elevated MCFP in rattlesnakes. To investigate adrenergic regulation on venous tone, adrenaline as well as phenylephrine and isoproterenol (alpha- and beta-adrenergic agonists, respectively) were infused as bolus injections (2 and 10 mu g kg(-1)). Adrenaline and phenylephrine caused large increases in MCFP and P-CV, whereas isoproterenol decreased both parameters. This was also the case in fully recovered snakes. Therefore, adrenaline affects venous tone through both alpha- and beta-adrenergic receptors, but the alpha-adrenergic receptor dominates at the dosages used in the present study. Injection of the nitric oxide donor SNP caused a significant decrease in P-CV and MCFP. Thus, nitric oxide seems to affect venous tone.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Block diagrams and signal-flow graphs are used to represent and to obtain the transfer function of interconnected systems. The reduction of signal-flow graphs is considered simpler than the reduction of block diagrams for systems with complex interrelationships. Signal-flow graphs reduction can be made without graphic manipulations of diagrams, and it is attractive for a computational implementation. In this paper the authors propose a computational method for direct reduction of signal-flow graphs. This method uses results presented in this paper about the calculation of literal determinants without symbolic mathematics tools. The Cramer's rule is applied for the solution of a set of linear equations, A program in MATLAB language for reduction of signal-flow graphs with the proposed method is presented.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This work presents the application of a multiobjective evolutionary algorithm (MOEA) for optimal power flow (OPF) solution. The OPF is modeled as a constrained nonlinear optimization problem, non-convex of large-scale, with continuous and discrete variables. The violated inequality constraints are treated as objective function of the problem. This strategy allows attending the physical and operational restrictions without compromise the quality of the found solutions. The developed MOEA is based on the theory of Pareto and employs a diversity-preserving mechanism to overcome the premature convergence of algorithm and local optimal solutions. Fuzzy set theory is employed to extract the best compromises of the Pareto set. Results for the IEEE-30, RTS-96 and IEEE-354 test systems are presents to validate the efficiency of proposed model and solution technique.
Resumo:
Introduction. Hypovolemia from hemorrhage evokes protective compensatory reactions, such as the renin-angiotensin system, which interferes in the clearance function and can lead to ischemia. This study was designed to evaluate the effects of glibenclamide, a K-ATP(+) channel blocker, on renal function and histology in rats in a state of hemorrhagic shock under sevoflurane anesthesia. Material and Methods. Twenty Wistar rats were randomized into two groups of 10 animals each (G1 and G2), only one of which (G2) received intravenous glibenclamide (1 mu g.g(-1)), 60 min before bleeding was begun. Both groups were anesthetized with sevoflurane and kept on spontaneous respiration with oxygen-air, while being bled of 30% of volemia in three stages with 10 min intervals. There was an evaluation of renal function-sodium para-aminohippurate and iothalamate clearances, filtration fraction, renal blood flow, renal vascular resistance-and renal histology. Renal function attributes were evaluated at three moments: M1 and M2, coinciding with the first and third stages of bleeding; and M3, 30 min after M2, when the animals were subjected to bilateral nephrectomy before being sacrificed. Results. Significant differences were found in para-aminohippurate clearance, G1 < G2, and higher renal vascular resistance values were observed in G1. Histological examination showed the greater vulnerability of kidneys exposed to sevoflurane alone (G1) with higher scores of vascular and tubular dilatation. There were vascular congestion and tubular vacuolization only in G1. Necrosis and signs of tubular regeneration did not differ in both groups. Conclusion. Treatment with glibenclamide attenuated acutely the renal histological changes after hemorrhage in rats under sevoflurane anesthesia.
Resumo:
OBJETIVO: Avaliar o efeito da utilização de um programa de treinamento específico dos músculos respiratórios sobre a função pulmonar em indivíduos tabagistas. MÉTODOS: Foram estudados 50 indivíduos tabagistas assintomáticos com idade superior a 30 anos, nos seguintes momentos: A0 - avaliação inicial seguida do protocolo de exercícios respiratórios; A1 - reavaliação após 10 minutos da aplicação do protocolo; e A2 -reavaliação final após duas semanas de treinamento utilizando o mesmo protocolo três vezes por semana. A avaliação foi realizada através das medidas de pressões respiratórias máximas (PImax. e PEmax.), picos de fluxo respiratórios (PFI e PFE), ventilação voluntária máxima (VVM), capacidade vital Forçada (CVF) e Volume expiratório forçado no primeiro segundo (VEF1). RESULTADOS: Não houve melhora na CVF e VEF1 da avaliação inicial para a final. Houve aumento significativo das variáveis PFI, PFE, VVM e PImax nas avaliações A1 e A2. A variável PEmax. aumentou somente na avaliação A2. CONCLUSÃO: A aplicação de protocolo de exercícios respiratórios com e sem carga adicional em indivíduos tabagistas produziu melhora imediata na performance dos músculos respiratórios, mas esta melhora foi mais acentuada após duas semanas de exercício.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)