47 resultados para Faults detect
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Near-infrared Raman spectroscopy (NIRS) is a particularly promising technique that is being used in recent years for many biomedical applications. Optical spectroscopy has gained increasing prominence as a tool for quantitative analysis of biological samples, clinical diagnostic, concentration measurements of blood metabolites and therapeutic drugs, and analysis of the chemical composition of human tissues. Toxoplasmosis is an important zoonosis in public health, and domestic cats are the most important transmitters of the disease. This disease can be detected by several serological tests, which usually have a high cost and require a long time. The goal of this work was to investigate a new method to diagnosis Toxoplasma gondii infections using NIRS. In order to confirm antibody detection, 24 cat blood scrum samples were analyzed by the Raman spectra, from which 23 presented positive serology to toxoplasmosis and one was a reference negative serum. Characteristic Raman peaks allowed differentiation between negative and positive sera, confirming the possibility of antibody detection by Raman spectroscopy. These results give the first evidence that this technique can be useful to quantify antibodies in cat sera.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The control of molecular architectures has been a key factor for the use of Langmuir-Blodgett (LB) films in biosensors, especially because biomolecules can be immobilized with preserved activity. In this paper we investigated the incorporation of tyrosinase (Tyr) in mixed Langmuir films of arachidic acid (AA) and a lutetium bisphthalocyanine (LuPc2), which is confirmed by a large expansion in the surface pressure isotherm. These mixed films of AA-LuPc2 + Tyr could be transferred onto ITO and Pt electrodes as indicated by FTIR and electrochemical measurements, and there was no need for crosslinking of the enzyme molecules to preserve their activity. Significantly, the activity of the immobilised Tyr was considerably higher than in previous work in the literature, which allowed Tyr-containing LB films to be used as highly sensitive voltammetric sensors to detect pyrogallol. Linear responses have been found up to 400 mu M, with a detection limit of 4.87 x 10(-2) mu M (n = 4) and a sensitivity of 1.54 mu A mu M-1 cm(-2). In addition, the Hill coefficient (h = 1.27) indicates cooperation with LuPc2 that also acts as a catalyst. The enhanced performance of the LB-based biosensor resulted therefore from a preserved activity of Tyr combined with the catalytic activity of LuPc2, in a strategy that can be extended to other enzymes and analytes upon varying the LB film architecture.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: The purpose of this study was to evaluate the efficacy of the laser fluorescence (LF) device in detecting in vitro demineralization and remineralization of smooth surface caries-like lesions. Background Data: The early detection of smooth surface caries-like lesions is important to provide proper management of carious lesions, and allows monitoring of them over time. Also, some authors suggest that LF could be useful in monitoring the caries pathological process. Materials and Methods: Seventy-eight blocks of bovine teeth were obtained, and then submitted to artificial caries lesion induction and to a pH-cycling process. Superficial microhardness (SMH) and laser fluorescence analysis were performed at baseline, after induction of caries-like lesions, and after the pH-cycling regimen to promote remineralization. Results: Friedman's and multiple comparison tests were performed for all variables. SMH analysis showed significant differences (p < 0.05) between baseline (286.77 +/- 1.49 Vickers hardness number [VHN] units), before (38.48 +/- 0.85 VHN), and after remineralization (131.93 +/- 2.63 VHN). Baseline values for LF were extremely low (2.71 +/- 0.05), and a statistically significant difference was observed only after remineralization (3.61 +/- 0.08), as demonstrated by the increase in LF values. Conclusion: The LF device did not show efficacy for monitoring in vitro demineralization and remineralization of smooth enamel surfaces.
Resumo:
Mutilation of extremities was very frequent in patients affected by leprosy in the past; although it is now much less common, it is still seen, mainly in patients with long-term disease. In general, mutilation of the nose and ears is caused by the bacillus and mutilation of the hands and feet a consequence of chronic trauma. Leprosy must be chronically treated and any decision to interrupt therapy is based on laboratory tests and biopsy. Scintigraphy is a non-invasive procedure which could be of great value in to determining disease activity. We studied eight patients (five males and three females, aged 64-73 years) who presented with mutilation of the nose (2), ear (1), feet (3) or foot and hand (2), Conventional three-phase bone scintigraphy (750 MBq) and X-ray examinations of the affected areas were performed in all patients. Bone scintigraphy was abnormal in four patients (the presence of bacilli was confirmed by biopsy in two of them), and normal in the other four. In all patients except for the one with ear mutilation, radiography only showed the absence of bone. We conclude that bone scintigraphy is very useful to determine disease activity in cases of mutilation caused by leprosy. It seems to be superior to conventional radiography and may enable bone biopsies to be avoided.
Resumo:
More sensitive methodologies are necessary to improve strongyloidiasis diagnosis. This study compared the sensitivities of the McMaster modified technique and polymerase chain reaction (PCR) assays, both performed in faecal samples. Lewis rats were subcutaneously infected with 4,000, 400 or 40 infective third-stage larvae, considered as high, moderate or low infection, respectively. Seven days later, they were euthanized to count adult nematodes recovered from the small intestine. Stool samples were used to count the number of eggs per gram (EPG) of faeces and to detect parasite DNA by PCR performed with a species and a genus primer pair. The sensitivity of these assays depended upon parasite burden and the primer specificity. All assays presented 100% sensitivity at the highest parasite load. In the moderate infection, EPG and PCR with the genus primer maintained 100% specificity, whereas PCR sensitivity with the species primer decreased to 77.7%. In low infection, the sensitivity was 60% for EPG, 0% for PCR with the species primer and 90% for PCR done with the genus primer. Together, these results suggest that PCR with a genus primer can be a very sensitive methodology to detect Strongyloides venezuelensisin faeces of Lewis rats infected with very low parasite burden.
Resumo:
objective: To analyze bioelectrical impedance performance in detecting the presence of excess visceral fat and overweight/obesity in young Brazilians and how its values are related with them.Methods: Study sample consisted of 811 adolescents of both genders (11 to 17 years of age). Nutritional status was determined based on triceps skinfold thickness (TSF), relative body fat (bioelectrical impedance), and excess visceral fat as determined by waist circumference. Statistical analysis was performed using means, standard deviations, linear correlation, Student's t test, and ROC curve.Results: Bioelectrical impedance achieved good performance in identifying excess visceral fat associated with overweight/obesity in both genders, and was found to be more specific (male 92.4% and female 93.8%) than sensitive (male 86.1% and female 71.8%).Conclusion: Our findings support the use of bioelectrical impedance to identify the presence of excess visceral and subcutaneous fat in adolescents.