49 resultados para FULL HYDRATION

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to determine the effect of maternal hydration with oral isotonic solution and water on the amniotic fluid (AF) index of women with normohydramnios. Women with a normal AF index and gestational age between 33 and 36 weeks without maternal complications were randomized into three groups [isotonic solution (Gatorade (R)), water, control]. The isotonic solution and water groups were instructed to drink 1.5 L of the respective solution and the control group was instructed to drink 200 mL water over a period of 2 to 4 h. AF index was measured before and after hydration by Doppler ultrasonography. The investigator performing the AF index measurement was blind to the subject's group. Ninety-nine women completed the study without any adverse maternal effects. The median increase in AF index after hydration was significantly greater for the isotonic solution and water groups than for the control group. There was no significant difference between the isotonic solution and water groups. Hydration with isotonic solution and water caused a 10-fold (95% CI: 2.09-49.89) and 6-fold (95% CI: 1.16-30.95) increase in the chance of a 20% increase of AF index, respectively. Maternal hydration with isotonic solution or water increased the AF index in women with normohydramnios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Although galactose is an important component in human lactose, there are few reports of its role in the newborn metabolism. Objective: To determine the relationship of blood galactose and glucose levels in mothers, cord blood, and breast-fed full-term newborn infants. Methods: Maternal and cord vein blood samples were obtained from 27 pregnant women at delivery, and from their breastfed, full-term newborns 48 h later. Galactose and glucose were determined by HPLC. Statistical analysis used ANOVA and Pearson correlation with p < 0.05. Results: Maternal galactose concentrations (0.08 +/- 0.03 mmol/l) were similar to cord blood galactose (0.07 +/- 0.03 mmol/l; p = 0.129). However, newborn blood galactose (0.05 +/- 0.02 mmol/l) was significantly lower than both cord (p = 0.042) and maternal blood (p = 0.002). Maternal blood glucose levels (4.72 +/- 0.86 mmol/l) were higher than cord blood (3.98 +/- 0.57 mmol/l; p < 0.001), and cord blood concentrations were higher than newborn blood levels (3.00 +/- 0.56 mmol/l; p < 0.001); all values expressed as mean +/- SD. Significant correlation was only seen between maternal and cord blood galactose levels (r = 0.67; p < 0.001) and glucose levels (r = 0.38; p = 0.047). Conclusion: the association and similarity between maternal and cord blood galactose levels suggest that the fetus is dependent on maternal galactose. In contrast, the lower galactose levels in newborn infants and a lack of association between both suggest self-regulation and a dependence on galactose ingestion. Copyright (c) 2007 S. Karger AG, Basel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The P transposable element copy numbers and the KP/full-sized P element ratios were determined in eight Brazilian strains of Drosophila melanogaster. Strains from tropical regions showed lower overall P element copy numbers than did strains from temperate regions. Variable numbers of full-sized and defective elements were detected, but the full-sized P and KP elements were the predominant classes of elements in all strains. The full-sized P and KP element ratios were calculated and compared with latitude. The northernmost and southernmost Brazilian strains showed fewer full-sized elements than KP elements per genome, and the strains from less extreme latitudes had many more full-sized P than KP elements. However, no clinal variation was observed. Strains from different localities, previously classified as having P cytotype, displayed a higher or a lower proportion of KP elements than of full-sized P elements, as well as an equal number of the two element types, showing that the same phenotype may be produced by different underlying genomic components of the P-M system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of application methods and dentin hydration on the bond strength of three self-etching adhesives (SEA) were evaluated; 195 extracted bovine incisors were used. The buccal surface was ground in order to expose the dentin, which remained 2-mm minimum thickness, measured by a thickness meter through an opening on the lingual surface. Adper Single Bond 2 (TM) was used for the control group. The SEA were applied following two modes of application: passive or active and two hydration states of the dentin surface-dry and wet. After light-curing, composite buildups were made using Grandio (TM) composite. The specimens were sectioned and tested with a microtensile bond strength test. The application method and the hydration state resulted in statistical differences (p = 0.000) making the values of active application for mu TBS to dentin higher than passive application. The wet surfaces showed higher mu TBS to dentin ratios than dry surfaces. There were no statistical differences in mu TBS among the SEA tested but there were differences regarding to control group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of surface hydration state and application method on the microtensile bond strength of one-step self-etching adhesives systems to cut enamel.Materials and Methods: One hundred ninety-five bovine teeth were used. The enamel on the buccal side was flattened with 600-grit SiC paper. For the control group, 15 teeth received Adper Single Bond 2, applied according to manufacturer's recommendations. The other specimens were divided into three groups according to the adhesive system used: Futura Bond M (FM; Voco), Clearfil S-3 Bond (CS; Kuraray), and Optibond All in One (OA; Kerr). For each group, two hydration states were tested: D: blown dry with air; W: the excess of water was removed with absorbent paper. Two application methods were tested: P (passive): the adhesive was simply left on the surface; A (active): the adhesive was rubbed with an applicator point. A coat of Grandio composite resin (Voco) was applied on the surface. The teeth were sectioned to obtain enamel-resin sticks (1 x 1 mm), which underwent microtensile bond testing. The data in MPa were submitted to a three-way ANOVA and Tukey's test (alpha = 5%).Results: The ANOVA showed significant differences for application method and the type of adhesive, but not for hydration state. For the application method, the results of Tukey's test were: P: 31.46 (+/-7.09)a; A: 34.04 (+/-7.19)b. For the type of adhesive, the results were: OA: 31.29 (+/-7.05)a; CS: 32.28 (+/-7.14)a; FM: 34.68 (+/-7.17)b; different lower-case letters indicate statistically significant differences.Conclusion: Active application improved the bond strength to cut enamel. The adhesive Futurabond M showed the highest bond strength to cut enamel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direct and simultaneous measurements of hydration water content and protein conformation have been performed using quartz crystal microbalance and visible absorption spectroscopy. Equilibrium and kinetics of methaemoglobin/haemichrome transition induced by the alteration of the degree of hydration was investigated in thin films exposed to controlled humidity. The kinetics experiment show that the conversion of species achieve the equilibrium more rapidly that the amount of sorbed water by the protein. The transition shows a sigmoid behaviour and suggest cooperative phenomena manifested by haem-haem interaction. The water hydration network contributing to the haem haem interaction advise that water acts as allosteric effectors for the conversion between species. Irreversible changes produced by complete drying are clearly shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The local environment of Er3+ ions in microporous titanosilicate ETS-10 and in synthetic narsarsukite and glassy materials obtained by calcination of ETS-10 has been investigated by EXAFS, Raman and photoluminescence spectroscopies. Er L-III-edge EXAFS studies of Er3+-doped ETS-10 support the view that the exchanged Er3+ ions reside close to the (negatively charged) TiO6 octahedra. In ETS-10, Er3+ is partially bonded to framework oxygen atoms and hydration water molecules. The Er...Ti distance (3.3 Angstrom) is similar to the Na...Ti distances (3.15-3.20 Angstrom) reported previously for Na-ETS-10. Although the exact location of the ErO6 units within the host structure of Er3+-doped synthetic narsarsukite is still an open question, it is most likely that Er3+ substitutes Ti4+ rather than Na+ ions. EXAFS spectroscopy indicates that no significant clustering of erbium atoms occurs in the titanosilicate samples studied. Evidence for the insertion of Er3+ ions in the framework of narsarsukite has been obtained by Raman spectroscopy. This is indicated by the increasing full-width at half-maximum (FWHM) of the 775 cm(-1) peak and the increasing intensity of the anatase peaks as the erbium content increases. In addition, as the narsarsukite Er3+ content increases a band at ca. 515 cm(-1) firstly broadens and subsequently a new peak appears at ca. 507 cm(-1).Er3+-doped narsarsukite exhibits a characteristic local vibrational frequency, (h) over bar omega ca. 330 cm(-1), with an electron-phonon coupling, g ca. 0.2, which constitutes additional evidence for framework Er3+ insertion. The number of lines in the infrared emission spectrum of synthetic narsarsukite indicates the presence of two optically-active erbium centres with very similar local environments and an average I-4(13/2) lifetime of 7.8 +/- 0.2 ms.