120 resultados para Expressió facial

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Pythiosis in horses is a proliferative and ulcerative disease that primarily affects the skin and subcutaneous tissue of limbs, thoracic-abdominal region and head. This disease sometimes can also affect limb bones or cause tumoral masses in abdomen. Usually, the cutaneous cases are confused with habronemiasis. The disease is more common in marshy areas, places with formation of slow drainage ponds and aquatic vegetation under high temperatures. The aim of this study was to describe the development of facial lesions in a horse caused by pythiosis in Cuiaba, Mato Grosso, and, additionally to discuss relevant issues regarding the diagnosis, clinical course and response to immunotherapy treatment.Case: One five years old mare of unknown breed, created in property located in the Cerrado region, had a wound on its face difficult to be healed and non-responsive to several treatments based on ivermectin and organophosphate administrated by either topical or systemic via. The animal was assisted on the farm of origin by the veterinary team of the Clinical Medicine sector, of the Veterinary Hospital, Universidade Federal de Mato Grosso (HOVET-UFMT). on the occasion of the visit, which occurred 60 days after onset of signs, the animal showed a circular single large lesion, ulcerative with serous discharge on the right part of its face, between the eyes and nostrils. There were some necrotic foci with sinus, from which kunkers were extracted; a condition compatible with pythiosis. The diagnosis was confirmed by histology, ELISA and PCR.Discussion: Assuming pythiosis from data obtained from the survey and profile of the lesion (secretory aspect, emaciation and presence of sinus and kunkers), immunotherapy treatment was immediately applied. The advanced clinical aspects and the fact that early diagnosis and treatment are essentials to satisfactory therapeutic response were also taken into consideration for starting the treatment. The remission of signs was achieved after five subcutaneous applications with 14 days between each application. From the second application, it was observed clinical improvement and after 60 days of treatment there was almost complete remission of signs. The signs for a satisfactory response in the injury site followed the order of decreasing secretory aspect, decreasing borders, decrease the itching and bringing the edges together with the formation of a thin layer of crust on the surface. Pythiosis cases with lesions on the face and lower abdomen are commonly confused with habronemiasis by macroscopic and widespread similarity between technicians and attendants, and essential support to the diagnosis through laboratory tests, which in turn are still underutilized. In this case, the authors demonstrated the therapeutic efficacy of immunotherapy as an advantage, considering the possibility of applying it in cases of lesions in areas of difficult surgical access, treatment conditions in the field, with low cost and ease of application. Further studies approaching this alternative therapy are necessary, since side effects have been observed in some cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the efficiency of the Pro-Fono Facial Exerciser (Pro-Fono Productos Especializaclos para Fonoaudiologia Ltda.., Barueri/SP, Brazil) to decrease bruxism, as well as the correlation between the masseter and the buccinator muscles using electromyography (EMG). In this study, 39 individuals ranging from 23 to 48 years of age were selected from a dental school and then underwent surface EMG at three different periods of time: 0, 10, and 70 days. They were divided into a normal control group, a bruxer control group (without device), and an experimental bruxer group who used the device. The bruxer group showed a greater masseter EMG amplitude when compared to the normal group, while the experimental group had deceased activity with a reduction in symptoms. The buccinator EMG spectral analysis of the experimental bruxist group showed asynchronous contractions of the masseter muscle (during jaw opening) after using the Pr6-Fono Facial Exerciser. The normal group also showed asynchronous contractions. Upon correlation of the data between these muscles, the inference is that there is a reduction in bruxism when activating the buccinator muscle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo apresenta documentos de paralisia facial periférica nas artes plásticas no Egito antigo, Grécia e Roma, Idade Média, Renascimento e também dos últimos 4 séculos. Pensamos que a história da paralisia facial periférica acompanha a história da própria espécie humana. São apresentadas as contribuições de Avicenna e Nicolaus Friedreich, e são mostradas controvérsias sobre a descrição original de Charles Bell.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hypothyroidism is the most commonly endocrinopathy in dogs, that occurs preferentially in middle-aged pure breed. The clinical signs associated with hypothyroidism are variable, many times non-specific, including metabolical, dermatological or cardiovascular. The main laboratorial findings are non-regenerative anemia and hypercholesterolemia. Hyponatremia, increase on alanine transferase and alkaline phosphatase activity also can be observed in a lower frequency. There are some reports of peripheral neuropathies caused by hypothyroidism, but the pathophysiology of this process is still unknown. There are specific diagnostic tests that can be used to help diagnose hypothyroidism, and those should be aligned together with the animal's clinical symptoms. The thyroxine stimulating hormone, and free and total thyroxine concentrations are the most used tests. A Pit Bull dog, female, over weighted, was treated presenting left facial paralysis. Thyroid function tests confirmed hypothyroidism. The animal was treated with hormonal replacement and there was improvement in clinical signs in 40 days, confirming that hypothyroidism was facial paralysis' cause.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Ramsay Hunt syndrome is a rare disease caused by an infection of the geniculate ganglion by the varicella-zoster virus. The main clinical features of the syndrome are as follows: Bell palsy unilateral or bilateral, vesicular eruptions on the ears, ear pain, dizziness, preauricular swelling, tingling, tearing, loss of taste sensation, and nystagmus. We describe a 23-year-old white woman, who presented with facial paralysis on the left side of the face, pain, fever, ear pain, and swelling in the neck and auricular region on the left side. She received appropriate treatment with acyclovir, vitamin B complex, and CMP nucleus. After 30 days after presentation, the patient did not show any signs or symptoms of the syndrome. At follow-up at 1 year, she showed no relapse of the syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to assess the behavior and stress distribution of 3 retention systems associated with implant for facial prosthesis by using the photoelasticity method. A photoelastic model was made from the replica of the orbital region on the left side of a dry skull with two 4-mm implants fixed in the superior orbital region. Three facial prosthetic retention systems were made for this study: O'ring, bar-clip, and magnets. The set (model/retention systems/prosthesis) was placed in a polariscope, and then traction began to be applied to the retention systems. The limit values for removal of the retention system were obtained by tests performed in an EMIC Universal test machine. The results were obtained by observation during the experiments and by photographic record of the stress behavior in the photoelastic model, resulting from the traction of the retention systems. In the magnet system, a lowest formation of fringes was verified both around and between the implants; in the O'ring system, the formation of photoelastic fringes was noted between the implants in the apical region; and in the bar-clip system, there was a greater concentration of colored fringes in the regions between the implants and cervical area. Based on the results obtained, it was concluded that the retention systems produced different stress distribution characteristics that, in general, were concentrated in the area around the implants, and the highest concentration of fringes, in increasing order, occurred ill the retention systems of the magnets, O'ring, and bar-clip.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The matching of the aesthetic, functional, and psychosocial results of a facial deformity may produce devastating effects in its carriers, especially if the lesion is extensive or the treatment is aggressive. Because of this, the objective of the present article was to evaluate patient's satisfaction rating after surgical facial reconstruction or rehabilitation with oral and maxillofacial prosthesis, by means of reviewing the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The failure of facial prostheses is caused by limitations in the properties of existing materials, especially the biocompatibility. This study aimed to evaluate the biocompatibility of maxillofacial silicones in subcutaneous tissue of rats. Thirty Wistar rats received subcutaneous implants of 3 maxillofacial silicone elastomers (LIM 6050, MDX 4-4210, and industrial Silastic 732 RTV). A histomorphometric evaluation was conducted to analyze the biocompatibility of the implants. Eight areas of 60.11 mm(2) from the surgical pieces were analyzed. Mesenchymal cells, eosinophils, and foreign-body giant cells were counted. Data were submitted to analysis of variance and Tukey test. Initially, all implanted materials exhibited an acceptable tissue inflammatory response, with tissue reactions varying from light to moderate. Afterward, a fibrous capsule around the silicone was observed. The silicones used in the current study presented biocompatibility and can be used for implantation in both medical and dental areas. Their prosthetic indication is conditioned to their physical properties. Solid silicone is easier to adapt and does not suffer apparent modifications inside the tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The failure of facial prostheses is caused by limitations in their flexibility and durability. Therefore, we evaluated the effects of disinfection and aging on Shore A hardness and deterioration of a facial silicone with different pigmentations. Twenty samples with addition of each pigment (ceramic (C), make-up (M)) and without pigment (L) were made. For each pigment type and no pigment, 10 samples were subjected to two types of disinfectant solution (soap (S) and Efferdent (E)), totaling sixty samples. The specimens were disinfected three times per week for 60 days, and subjected to accelerated aging for 1008 h. The hardness of the facial silicone was measured with a durometer, and its deterioration was evaluated by obtaining the weight difference over time. Both the hardness and weight of the samples were measured at baseline, after chemical disinfection, and periodically during accelerated aging (252, 504, and 1008 h). Deterioration was calculated during the periods between baseline and chemical disinfection, and between baseline and each aging period. The results were analyzed using three-way repeated measures ANOVA and the Tukey's HSD Post-hoc test (alpha = 0.05). Specifically, samples containing pigment exhibited significantly higher hardness and deterioration values than those lacking pigment (P < 0.05). In addition, period of time (disinfection and accelerated aging) statistically increased the hardness and deterioration values of the silicone (P < 0.05). It can be concluded that both pigment and time statistically affected the hardness and deterioration of the silicone elastomer. (c) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the study was to report the prevention of facial reinjury of a volleyball player using a custom-made protective facial shield. A custom-made protective partial facial shield was fabricated using polymethylmethacrylate and was fitted with a soft lining material to provide additional comfort and protection to the injured area. Facial protection provides greater security against possible facial injuries and allows injured areas to recover during sports practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)