53 resultados para Error of measurement

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a general modeling approach to investigate and to predict measurement errors in active energy meters both induction and electronic types. The measurement error modeling is based on Generalized Additive Model (GAM), Ridge Regression method and experimental results of meter provided by a measurement system. The measurement system provides a database of 26 pairs of test waveforms captured in a real electrical distribution system, with different load characteristics (industrial, commercial, agricultural, and residential), covering different harmonic distortions, and balanced and unbalanced voltage conditions. In order to illustrate the proposed approach, the measurement error models are discussed and several results, which are derived from experimental tests, are presented in the form of three-dimensional graphs, and generalized as error equations. © 2009 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to assess measurements of temperature and relative humidity obtained with HOBO a data logger, under various conditions of exposure to solar radiation, comparing them with those obtained through the use of a temperature/relative humidity probe and a copper-constantan thermocouple psychrometer, which are considered the standards for obtaining such measurements. Data were collected over a 6-day period (from 25 March to 1 April, 2010), during which the equipment was monitored continuously and simultaneously. We employed the following combinations of equipment and conditions: a HOBO data logger in full sunlight; a HOBO data logger shielded within a white plastic cup with windows for air circulation; a HOBO data logger shielded within a gill-type shelter (multi-plate prototype plastic); a copper-constantan thermocouple psychrometer exposed to natural ventilation and protected from sunlight; and a temperature/relative humidity probe under a commercial, multi-plate radiation shield. Comparisons between the measurements obtained with the various devices were made on the basis of statistical indicators: linear regression, with coefficient of determination; index of agreement; maximum absolute error; and mean absolute error. The prototype multi-plate shelter (gill-type) used in order to protect the HOBO data logger was found to provide the best protection against the effects of solar radiation on measurements of temperature and relative humidity. The precision and accuracy of a device that measures temperature and relative humidity depend on an efficient shelter that minimizes the interference caused by solar radiation, thereby avoiding erroneous analysis of the data obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A paradox is pointed out and resolved by proving that the average energy E = [H] of a macroscopic system in thermal equilibrium must increase by the measurement of an observable A which does not commute with the Hamiltonian H. The proof follows as a corollary of a more general result, which states that under certain conditions the expectation value [C] of an observable C should increase by the measurement of another observable A, if [A, C] not-equal 0.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste estudo foi comparar os níveis de adiposidade subcutânea dos hemicorpos direito e esquerdo e, posteriormente, analisar o impacto dessas informações para o estudo da composição corporal. Setenta e seis indivíduos fisicamente ativos, 47 homens (21,6 ± 4,3 anos) e 29 mulheres (21,0 ± 2,6 anos), fizeram parte da amostra. As espessuras das dobras cutâneas abdominal, suprailíaca, subescapular, tricipital, bicipital, axilar média e perna medial foram mensuradas com um compasso Lange. Em valores médios absolutos, as maiores diferenças verificadas foram de 0,9mm (6,9%) e 0,8mm (6,8%), na dobra cutânea suprailíaca de homens e mulheres, respectivamente. Entretanto, nenhuma diferença estatisticamente significante foi encontrada na comparação entre os lados, em ambos os sexos, nas sete dobras cutâneas analisadas (P > 0,05). Similarmente, quando os valores medidos foram aplicados em equações preditivas para a determinação da gordura corporal relativa, de acordo com o sexo, nenhuma diferença significante foi encontrada (P > 0,05). Os resultados sugerem que fatores como o erro técnico de medida do avaliador, o tipo de compasso e a escolha da equação preditiva a ser utilizada, provavelmente tenham maior impacto para a estimativa da composição corporal pelo método de espessura de dobras cutâneas do que o lado a ser adotado como referência para a obtenção das medidas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work is to evaluate the influence of point measurements in images, with subpixel accuracy, and its contribution in the calibration of digital cameras. Also, the effect of subpixel measurements in 3D coordinates of check points in the object space will be evaluated. With this purpose, an algorithm that allows subpixel accuracy was implemented for semi-automatic determination of points of interest, based on Fõrstner operator. Experiments were accomplished with a block of images acquired with the multispectral camera DuncanTech MS3100-CIR. The influence of subpixel measurements in the adjustment by Least Square Method (LSM) was evaluated by the comparison of estimated standard deviation of parameters in both situations, with manual measurement (pixel accuracy) and with subpixel estimation. Additionally, the influence of subpixel measurements in the 3D reconstruction was also analyzed. Based on the obtained results, i.e., on the quantification of the standard deviation reduction in the Inner Orientation Parameters (IOP) and also in the relative error of the 3D reconstruction, it was shown that measurements with subpixel accuracy are relevant for some tasks in Photogrammetry, mainly for those in which the metric quality is of great relevance, as Camera Calibration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Smith-Lemli-Opitz syndrome (SLOS) is an autosomal recessive disorder due to an inborn error of cholesterol metabolism, characterized by congenital malformations, dysmorphism of multiple organs, mental retardation and delayed neuropsychomotor development resulting from cholesterol biosynthesis deficiency. A defect in 3ß-hydroxysteroid-delta7-reductase (delta7-sterol-reductase), responsible for the conversion of 7-dehydrocholesterol (7-DHC) to cholesterol, causes an increase in 7-DHC and frequently reduces plasma cholesterol levels. The clinical diagnosis of SLOS cannot always be conclusive because of the remarkable variability of clinical expression of the disorder. Thus, confirmation by the measurement of plasma 7-DHC levels is needed. In the present study, we used a simple, fast, and selective method based on ultraviolet spectrophotometry to measure 7-DHC in order to diagnose SLOS. 7-DHC was extracted serially from 200 µl plasma with ethanol and n-hexane and the absorbance at 234 and 282 nm was determined. The method was applied to negative control plasma samples from 23 normal individuals and from 6 cases of suspected SLOS. The method was adequate and reliable and 2 SLOS cases were diagnosed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the tropical Atlantic Forest, 42 canopy gaps had their areas estimated using four different field methods of measurement: Runkle, Brokaw and Green [Runkle, J.R., 1981. Gap formation in some old-growth forests of the eastern United States. Ecology 62, 1041-1051; Brokaw, N.V.L., 1982. The definition of treefall gap and its effect on measures of forest dynamics. Biotropica 14, 158-160; Green, P.T., 1996. Canopy Gaps in rain forest on Christmas Island, Indian Ocean: size distribution and methods of measurement. J. Trop. Ecol. 12, 427-434] and a new method proposed in this work. It was found that within the same gap delimitation, average gap size varied from 56.0 up to 88.3 m(3) while total sum of gap area varied from 2351.3 to 3707.9 m(3) Differences among all methods and between pairs of method proved to be statistically significant. As a consequence, gap size-class distribution was also different between methods. When one method is held as a standard, deviation on average values of gap size ranged between 11.8 and 59.7% as deviations on single gap size can reach 172.8%. Implications on forest dynamics were expressed by the forest turnover rate that was 24% faster or 15% slower depending on the method adopted for gap measurement. Based on my results and on methods' evaluation, the use of a new method is proposed here for future research involving the measure of gap size in forest ecosystems. Finally, it is concluded that forest comparisons disregarding the influence of different methods of gap measurement should be reconsidered. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this paper is to present a photogrammetric method for determining the dimensions of flat surfaces, such as billboards, based on a single digital image. A mathematical model was adapted to generate linear equations for vertical and horizontal lines in the object space. These lines are identified and measured in the image and the rotation matrix is computed using an indirect method. The distance between the camera and the surface is measured using a lasermeter, providing the coordinates of the camera perspective center. Eccentricity of the lasermeter center related to the camera perspective center is modeled by three translations, which are computed using a calibration procedure. Some experiments were performed to test the proposed method and the achieved results are within a relative error of about 1 percent in areas and distances in the object space. This accuracy fulfills the requirements of the intended applications. © 2005 American Society for Photogrammetry and Remote Sensing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paperwork presents the complete circuitry used to build a microcontroller-based pH-meter. Key control software is also discussed. An industry-standard glass combination electrode has been employed for pH detection. Electrode parameter extraction procedure is presented. Good measurement results, with 1 % error, have been attained. Copyright© (2006) by the International Measurement Federation (IMEKO).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to demonstrate the effectiveness of rugoscopy as a human identification method, even when the patient is submitted to rapid palatal expansion, which in theory would introduce doubt. With this intent, the Rugoscopic Identity was obtained for each subject using the classification formula proposed by Santos based on the intra-oral casts made before and after treatment from patients who were subjected to palatal expansion. The casts were labeled with the patients' initials and randomly arranged for studying. The palatine rugae kept the same patterns in every case studied. The technical error of the intra-evaluator measurement provided a confidence interval of 95%, making rugoscopy a reliable identification method for patients who were submitted to rapid palatal expansion, because even in the presence of intra-oral changes owing to the use of palatal expanders, the palatine rugae retained the biological and technical requirements for the human identification process. © 2012 American Academy of Forensic Sciences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oxidative stress is a key component in the immunosuppression of chronic kidney disease (CKD), and neutrophil function may be impaired by oxidative stress. To test the hypothesis that in uremic dogs with CKD, oxidative stress is increased and neutrophils become less viable and functional, 18 adult dogs with CKD were compared with 15 healthy adult dogs. Blood count and urinalysis were done, and the serum biochemical profile and plasma lipid peroxidation (measurement of thiobarbituric acid reactive substances) were determined with the use of commercial reagents. Plasma total antioxidant capacity (TAC) was measured with a spectrophotometer and commercial reagents, superoxide production with a hydroethidine probe, and the viability and apoptosis of neutrophils with capillary flow cytometry and the annexin V-PE system. The plasma concentrations of cholesterol (P = 0.0415), creatinine (P < 0.0001), and urea (P < 0.0001) were significantly greater in the uremic dogs than in the control dogs. The hematocrit (P = 0.0004), urine specific gravity (P = 0.015), and plasma lipid peroxidation (P < 0.0001) were significantly lower in the dogs that were in late stages of CKD than in the control group. Compared with those isolated from the control group, neutrophils isolated from the CKD group showed a higher rate of spontaneous (0.10 ± 0.05 versus 0.49 ± 0.09; P = 0.0033; median ± standard error of mean) and camptothecin-induced (18.53 ± 4.06 versus 44.67 ± 4.85; P = 0.0066) apoptosis and lower levels of superoxide production in the presence (1278.8 ± 372.8 versus 75.65 ± 86.6; P = 0.0022) and absence (135.29 ± 51.74 versus 41.29 ± 8.38; P = 0.0138) of phorbol-12-myristate-13-acetate stimulation. Thus, oxidative stress and acceleration of apoptosis occurs in dogs with CKD, the apoptosis diminishing the number of viable neutrophils and neutrophil superoxide production.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Cocaine is one of the most widespread illegal stimulants utilized by the human population throughout the world. The aim of this study was to establish the highest no-effect dose (HNED) of cocaine on the spontaneous locomotor activity (SLA) of horses in a behavior chamber, and thereby to determine the maximal acceptable threshold of the urinary drug concentration in horses. Twelve English thoroughbred mares received 0.02, 0.03, 0.04, 0.08 or 0.12 mg kg(-1) cocaine i.v. or saline solution (control). It was noted that doses above 0.04 mg kg(-1) induced a significant increase in SLA (P < 0.05, Tukey's test). No significant increase in SLA was seen in the mares that received 0.03 mg kg(-1), but the animals showed important behavioral changes that did not occur after the 0.02 mg kg(-1) dose. It was concluded that the HNED of cocaine for horses in a behavior chamber is 0.02 mg kg(-1). After injection of this dose in five horses, urine samples were collected at predetermined intervals through vesical catheterization. The concentrations of cocaine, norcocaine, benzoylecgonine and ecgonine methyl ester were quantified by liquid chromatography/electrospray ionization tandem mass spectrometry. Cocaine and norcocaine concentrations remained consistently below the level of detection. Benzoylecgonine reached a mean (+/- SEM) maximum concentration of 531.9 +/- 168.7 ng ml(-1) after 4 h, whereas ecgonine methyl ester peaked 2 h after injection at a concentration of 97.2 +/- 26.5 ng ml(-1). The maximum admissible concentration for cocaine and/or metabolites in the urine of horses is difficult to establish unequivocally because of the substantial individual variation in the drug elimination pattern observed in horses, which can be inferred by the large standard error of the means obtained. Copyright (C) 2002 John Wiley Sons, Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)