496 resultados para Equine semen

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evaluation of the damage caused by the sperm preservation process is crucial to improving fertilization rates. The objective of this study was to evaluate the effects of refrigeration temperature (5°C and 15°C) and storage time (0, 12, 24, 48, and 72 hours) on apoptotic markers in equine semen. Membrane phosphatidylserine translocation index, caspase activation index, and DNA fragmentation index were analyzed using epifluorescence microscopy. Analysis of variance was used for statistical analysis, and Tukey test was used to compare means. The significance level was set at P < .05. The results demonstrated that for transport duration shorter than 24 hours, semen quality was maintained when stored at either 5°C or 15°C. A storage temperature of 5°C should be used when it is necessary to transport semen for longer than 24 hours. There was a significant decrease in semen quality after 48 hours of refrigeration. © 2013 Elsevier Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present study, different freezing systems (Styrofoam box and Mini Digitcool ZH 400) and storage volumes (0.5- and 0.25-mL straws) were compared with regard to sperm kinetics and plasma membrane integrity of frozen and thawed semen. For that, three ejaculates from four animals were frozen in Styrofoam box and Mini Digitcool ZH 400 machine. The 0.5-mL straws were thawed at 46°C for 20 seconds, and the 0.25-mL straws were thawed at 46°C for 12 seconds. Statistical analysis was performed using program R of descriptive analysis box plot, followed by analysis of variance using PROC MIXED of SAS 9.1 package. Variances of 5% were considered as different. There was no interaction between the straw sizes and volumes; however, statistical differences were observed between the semen storage volumes. The 0.5-mL straws had higher total motility (%), progressive motility (%), average path velocity (μm/s), straight-line velocity (μm/s), curvilinear velocity (μm/s), and rapid sperm percentage (%) than the 0.25-mL straws. However, plasma membrane integrity analysis did not differ between the two straws. Thus, it is possible to conclude that equine sperm cryopreserved in 0.5-mL straws has better sperm kinetics than when stored in 0.25-mL straws. Additionally, it is possible to conclude that automated systems that enable faster freezing rates result in a seminal quality that is similar to the one obtained by the conventional system using Styrofoam boxes. © 2013 Elsevier Inc.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of the current study was to verify that stallion, spermatoza could be cooled for 24 hours and then frozen. In experiment I, one ejaculate from each of 13 stallions was used. Semen was collected and split into two parts; one part immediately frozen using standard cryo-preservation techniques and the other diluted, stored in an Equitainer for 24 hours, and then frozen. In experiment II, one ejaculate from each of 12 stallions was collected, diluted with Botu-Semen, and split into two parts: one cooled in an Equitainer and the other in Max-Semen Express without prior centrifugation. After 24 hours of cooling, the samples were centrifuged to remove seminal plasma and concentrate the sperm, and resuspended in Botu-Crio (R) extender containing on e of three cryoprotectant treatments (1% glycerol + 4% dimethylformamide, 1% glycerol + 4% dimethylacetamide and 1% glycerol + 4% methylformamide), maintained at 5 degrees C for 20 minutes, then frozen in nitrogen vapour. No difference was observed between the two cooling systems. The association of 1% glycerol and 4% methylformamide provided the best post-thaw progressive motility. For experiment III, two stallions were used for a fertility trial. Forty three inseminations were performed using 22 mares. No differences were seen in semen parameters and pregnancy rates when comparing the two freezing protocols (conventional and cooled/frozen). Pregnancy rates for conventional and cooled/frozen semen were, respectively, 72.7% and 82.3% (stallion A), and 40.0% and 50.0% (stallion B). We concluded that cooling equine-semen for 24 hours before freezing while maintaining sperm viability and fertility is possible.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Removal of excess seminal plasma is sometimes necessary to increase the quality and the longevity of cooled equine semen; moreover, this procedure is an indispensable step aiming to concentrate the sperm cells before freezing equine semen. Typically, the removal of seminal plasma is achieved by centrifugation; however, studies have shown that the force and duration of centrifugation can damage sperm cells and reduce the sperm recovery rate. Recently, new methodologies, such as cushion and filtration, have been described that aim to decrease the mechanical damage of centrifugation to sperm cells. This study aims to compare different methods for concentrating stallion semen.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Cooling of equine semen obtained from some stallions results in lower seminal quality and viability when the seminal plasma (SP) is present. The objective of this study was to evaluate the effect of the removal of SP using a Sperm Filter on the viability of cooled stallion semen. For this purpose, 31 stallions were used. Their ejaculates were divided into three groups: CN, semen was diluted with an extender; FLT, SP was removed by filtration; and CT, SP was removed by centrifugation and cooled to 15°C for 24 hours. Sperm kinetics and plasma membrane integrity were evaluated immediately after collection (T0) and after 24 hours of refrigeration (T1). No difference (P > .05) was noted at T1 for total sperm motility (TM), progressive sperm motility, or plasma membrane integrity when semen samples from all the stallions were analyzed. However, when samples from stallions termed bad coolers were analyzed (TM = <30% at T1), a difference was observed in TM and progressive sperm motility for CN compared with FLT and CT at T1. Sperm recovery was greater when SP was removed using the filter (FLT) to that when the SP was removed by centrifugation (CN) (89% vs. 81%). Thus, we concluded that filtering with a Sperm Filter is an efficient and practical method for removal of SP from stallion ejaculates, with lower sperm loss than centrifugation. We also found that the presence of SP reduces the quality and viability of cooled semen from stallions whose semen is sensitive to the process of refrigeration. © 2013 Elsevier Inc.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Seminal plasma removal, an indispensable step in equine semen cryopreservation, is usually done by centrifugation, but this might cause mechanical damage to sperm. A new method for seminal plasma removal from stallion semen, namely a filter composed of a synthetic hydrophilic membrane (Sperm Filter, BotuPharma, Botucatu, Sao Paulo, Brazil), was recently proposed. The objective of this study was to test the use of the Sperm Filter in the removal of seminal plasma before freezing stallion semen. Ejaculates from 31 stallions were divided into two groups and cryopreserved. In group 1 (G1), seminal plasma was removed with the Sperm Filter, and in group 2 (G2), seminal plasma was removed by centrifugation (600× g for 10 minutes). There were no differences (P < 0.05) between G1 and G2 in sperm kinetic parameters or plasma membrane integrity before or after cryopreservation. However, sperm recovery rate was higher (P < 0.05) for G1 versus G2 (mean ± SD, 89.4 ± 7.4% vs. 80.9 ± 5.5%). Therefore, the Sperm Filter was as efficient as centrifugation in removing seminal plasma from the stallion ejaculate. However, filtering was more practical and had significantly fewer sperm lost than the centrifugation technique. © 2013 Elsevier Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Cento e vinte ciclos estrais de cento e cinco fêmeas eqüinas da raça Mangalarga Marchador foram analisados com o objetivo de estudar o efeito do número de inseminações artificiais por ciclo sobre a fertilidade de éguas inseminadas com sêmen resfriado. Os ciclos foram acompanhados por palpação retal e rufiação, e as inseminações realizadas a cada 48 horas, a partir de um folículo de 30-35 mm de diâmetro até a ovulação, com sêmen diluído, resfriado a 20ºC e transportado. As éguas foram aleatoriamente distribuídas nos seguintes grupos: T1 - uma IA/ciclo, T2 - duas IA/ciclo e T3 - três ou mais IA/ciclo. As taxas de concepção ao primeiro ciclo foram, respectivamente, para T1, T2 e T3, de 47,83% (11/23), 70,00% (21/30) e 45,16% (14/31) e, após cinco ciclos, de 51,43% (18/35), 48,89% (22/45), e 47,50% (19/40) (P>0,05). O número de IA/ciclo não teve efeito sobre a fertilidade das éguas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ninety-seven Mangalarga Marchador mares were allocated in a randomized experimental design, with different number of replicates per treatments. The objective of this experiment was to study the effect of raw (T3) or diluted, cooled semen transported to the breeding farms 1 (T1) and 3 (T2), on mare fertility and different aspects of reproductive efficiency. The mares were inseminated, with semen of only one stallion (Farm 2), on alternate days using different inseminating volumes, according to number of inseminated mares per day using only one ejaculate. For transportation, semen diluted in a lactose-egg yolk modified extender and the MSP-2 container were used. There was no difference among treatments in relation to conception rates of mares inseminated with raw or diluted, cooled and transported semen. Regardless of the farm, the total fertility obtained with cooled semen was 80% (52/65). The following variables were not affected by the treatments: cycles/mare, cycles/pregnant mare, cycles/pregnancy, pregnancy/cycle, number of inseminations/mare, number of inseminations/pregnant mare, number of inseminations/open mare and efficiency of pregnancy. However, the breeding farm had an effect on water and semen temperature in the container, time between collection and insemination, according to time and distance covered. Based on the results, cooling and transporting equine semen, using an extender, lactose-egg yolk without glycerine and the MSP-2 container should be recommended for short distances. The use of raw semen immediately after collection is also recommended.