3 resultados para Entraînement en endurance
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Objective The present study aimed to examine the reproducibility of heart rate (HR) and rating of perceived exertion (RPE) values obtained during different incremental treadmill tests. Equipment and methods Twenty male, recreational, endurance-trained runners (10-km running pace: 10–15 km·h−1) performed, in a counterbalanced order, three continuous incremental exercise tests with different speed increments (0.5 km·h−1, 1 km·h−1 and 2 km·h−1). Thereafter, each participant performed the three tests again, maintaining the same order as before. The reproducibility of the HR and RPE values were analyzed for all protocols during submaximal intensities (8, 10, 12, and 14 km·h−1). In addition, it was examined the reproducibility of maximal HR (HRmax) and peak RPE (RPEpeak). Results The variability of both the HR and RPE values showed a tendency to decrease over the stages during the incremental test and was not or slightly influenced by the incremental test design. The HR at 14 km·h−1 and HRmax presented the highest reproducibility (CV < 2%). In contrast, the submaximal RPE values showed higher variability indices (i.e., CV > 5.0%). In conclusion, the HR values were highly reproducible during the stages of the incremental test, in contrast to the RPE values that presented limited reproducibility.
Resumo:
O objetivo deste estudo foi analisar a validade do consumo máximo de oxigênio (VO2max), da velocidade correspondente ao VO2max (vVO2max), do tempo de exaustão na vVO2max (Tlim), da economia de corrida (EC) e do limiar anaeróbio (LAn) para a predição da performance de atletas de endurance. Quatorze corredores de endurance (33,4 ± 4,4 anos; 62,7 ± 4,3kg; 166,1 ± 5,0cm; VO2max = 60,4 ± 5,9ml.kg-1.min-1) realizaram os seguintes testes: a) competição simulada nas distâncias de 1.500 e 5.000m. e; b) testes de laboratório para a determinação do VO2max, vVO2max, EC, LAn e Tlim na intensidades de 100% vVO2max. As velocidades (km/h) da vVO2max (18,7 ± 0,8), LAn (17,3 ± 1,1) v1.500m (19,9 ± 0,8) e v5.000m (17,9 ± 0,9) foram significantemente diferentes. A regressão múltipla stepwise revelou que o LAn foi o único preditor da performance da v5.000m, explicando 50% da variação desta performance. Para a v1.500m, o Tlim e a vVO2max explicaram 88% da variação da performance. Com base em nossos resultados, pode-se concluir que a validade dos índices fisiológicos (VO2max, vVO2max, Tlim, EC e LAn), para a predição da performance aeróbia de atletas de endurance, é dependente da distância da prova (1.500 x 5.000m) analisada.
Resumo:
Aim. The aim of the study was to verify whether endurance training may induce changes on the percentage of peak heart rate (% peak HR) at the lactate threshold (LT) intensity in untrained elderly. Methods. Sixteen healthy men (64.3 ± 4.1 yrs) underwent an incremental test on cycloergometer to determine the LT and the corresponding % peak HR at LT intensity. Afterwards, they were randomly distributed into two groups (n = 8 each): endurance training (ET) and control (C). The ET exercised 3 days a week for 12 weeks. The training session was divided into warm-up (5 min at 50% of LT;), a main part, and a cool-down (5 min 50% below of LT). The main part had a gradual increased volume through the weeks of 2 min. The initial volume on the 1st week was 25 min reaching 47 min at the 12th week. The relative intensity was kept constant (90 to 100% of LT). Results. After 12 weeks, the % peak HR at LT did not change significantly for both groups P > 0.05 (ET 82.9 ± 4.1 vs. 82.5 ± 3.4 and Ç 80.2 ± 7.1 vs. 81.8 ± 7.1). Conclusion. We conclude that endurance training proposed does not change the relative intensity at LT in elderly.