21 resultados para Engine cooling systems.

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Evaporative cooling operates using water and air as working fluids. It consists in water evaporation, through the passage of an airflow, thus decreasing the air temperature. This system has a great potential to provide thermal comfort in places where air humidity is low, being, however, less efficient where air humidity is high. A way to solve this problem is to use dehumidifiers to pre-conditioning the process air. This paper presents a system that can be used in humid climates coupling desiccant dehumidification equipment to evaporative coolers. The paper shows, initially, the main characteristics of the evaporative cooling and of the adsorption dehumidification systems. Later on the coupled systems, in which occurs a dehumidification by adsorption in a counter flow rotary heat exchanger following the evaporate cooling of the air in evaporative coolers, are analyzed. The thermodynamic equations of state are also presented. Following, this paper analyzes some operation parameters such as: reactivation temperature, R/P relationship (reactivation air flow/ process air flow) and the thermodynamic conditions of the entering air flow. The paper shows the conditions for the best operation point, with regard to thermal comfort conditions and to the energy used in the process. In addition this paper presents an application of the system in different climate characteristics of several tropical and equatorial cities. Copyright © 2005 by ABCM.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of the current study was to verify that stallion, spermatoza could be cooled for 24 hours and then frozen. In experiment I, one ejaculate from each of 13 stallions was used. Semen was collected and split into two parts; one part immediately frozen using standard cryo-preservation techniques and the other diluted, stored in an Equitainer for 24 hours, and then frozen. In experiment II, one ejaculate from each of 12 stallions was collected, diluted with Botu-Semen, and split into two parts: one cooled in an Equitainer and the other in Max-Semen Express without prior centrifugation. After 24 hours of cooling, the samples were centrifuged to remove seminal plasma and concentrate the sperm, and resuspended in Botu-Crio (R) extender containing on e of three cryoprotectant treatments (1% glycerol + 4% dimethylformamide, 1% glycerol + 4% dimethylacetamide and 1% glycerol + 4% methylformamide), maintained at 5 degrees C for 20 minutes, then frozen in nitrogen vapour. No difference was observed between the two cooling systems. The association of 1% glycerol and 4% methylformamide provided the best post-thaw progressive motility. For experiment III, two stallions were used for a fertility trial. Forty three inseminations were performed using 22 mares. No differences were seen in semen parameters and pregnancy rates when comparing the two freezing protocols (conventional and cooled/frozen). Pregnancy rates for conventional and cooled/frozen semen were, respectively, 72.7% and 82.3% (stallion A), and 40.0% and 50.0% (stallion B). We concluded that cooling equine-semen for 24 hours before freezing while maintaining sperm viability and fertility is possible.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tungsten coil atomic emission spectrometry is an ideal technique for field applications because of its simplicity, low cost, low power requirement, and independence from cooling systems. A new, portable, compact design is reported here. The tungsten coil is extracted from an inexpensive 24 V, 250 W commercial light bulb. The coil is housed in a small, aluminum cell. The emission signal exits from a small aperture in the cell, while the bulk of the blackbody emission from the tungsten coil is blocked. The resulting spectra exhibit extremely low background signals. The atomization cell, a single lens, and a hand-held charge coupled device (CCD) spectrometer are fixed on a 1 x 6 x 30 cm ceramic base. The resulting system is robust and easily transported. A programmable, miniature 400 W solid-state constant current power supply controls the temperature of the coil. Fifteen elements are determined with the system (Ba, Cs, Li, Rb, Cr, Sr, Eu, Yb, Mn, Fe, Cu, Mg, V, Al, and Ga). The precision ranges from 4.3% to 8.4% relative standard deviation for repetitive measurements of the same solution. Detection limits are in the 0.04 to 1500 mu g/L range. Accuracy is tested using standard reference materials for polluted water, peach leaves, and tomato leaves. For those elements present above the detection limit, recoveries range from 72% to 147%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present work shows an experimental and theoretical study on heat flow when end milling, at high-speed, hardened steels applied to moulds and dies. AISI H13 and AISI D2 steels were machined with two types of ball nose end mills: coated with (TiAl)N and tipped with PcBN. The workpiece geometry was designed to simulate tool-workpiece interaction in real situations found in mould industries, in which complex surfaces and thin walls are commonly machined. The compressed and cold air cooling systems were compared to dry machining Results indicated a relatively small temperature variation, with higher range when machining AISI D2 with PcBN-tipped end mill. All cooling systems used demonstrated good capacity to remove heat from the machined surface, especially the cold air. Compressed air was the most indicated to keep workpiece at relatively stable temperature. A theoretical model was also proposed to estimate the energy transferred to the workpiece (Q) and the average convection coefficient ((h) over bar) for the cooling systems used. The model used a FEM simulation and a steepest decent method to find the best values for both variables. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Jersey cows has been used in warm climates because they have better performance in dairy production. Generally milk production is reduced in warm climates due to the consequent reduction in feed intake because of the heat stress. When the heat stress occurs there is an increase in the body temperature, however it is not known if the skin temperature indicates a thermal discomfort or if it influences milk yield. The objective of this research was to verify if there was a correlation between skin temperature and milk yield using two treatments. Treatment (A) where the cows stayed for 30 minutes before the milking period, in a room with a shower and a fan; and treatment (B) where the cows did not had access to any cooling device (control). After milking the skin temperature were recorded in the places: forehead, back, leg and teats. Data were statistically analyzed and, even though in treatment (A) the skin temperature were reduced it was not found correlation between skin temperature and milk yield.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Biometrics is one of the biggest tendencies in human identification. The fingerprint is the most widely used biometric. However considering the automatic fingerprint recognition a completely solved problem is a common mistake. The most popular and extensively used methods, the minutiae-based, do not perform well on poor-quality images and when just a small area of overlap between the template and the query images exists. The use of multibiometrics is considered one of the keys to overcome the weakness and improve the accuracy of biometrics systems. This paper presents the fusion of a minutiae-based and a ridge-based fingerprint recognition method at rank, decision and score level. The fusion techniques implemented leaded to a reduction of the Equal Error Rate by 31.78% (from 4.09% to 2.79%) and a decreasing of 6 positions in the rank to reach a Correct Retrieval (from rank 8 to 2) when assessed in the FVC2002-DB1A database. © 2008 IEEE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The current technological development made by the absorption refrigeration system is an economic and ambient alternative in comparison to the vapor cycle, possessing an advantage that uses thermal energy that is less noble. Chillers of absorption are used widely in the air conditioned industries, because they can be set in motion through hot water vapors that burn natural gas, solar energy, biomasses amongst others instead of electricity. These systems allow it to reduce the tips of electric demand and balance the rocking of energy demand. This work has had a main objective to simulate a absorption refrigeration cycle with lithium-water bromide solution using biogas of sanitary landfill, and mixtures of this with natural gas. These results shown to the energy viability of the system burning biogas and its mixtures with natural gas in the generator, when compared with equipments that uses traditional fuels (natural gas, oil diesel, amongst others), for operation the commercial chillers with 15 kW of the refrigeration capacity and temperature of the water in the entrance of 14°C and the exit of 7°C.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, experimental results are reported for a small scale cogeneration plant for power and refrigeration purposes. The plant includes a natural gas microturbine and an ammonia/water absorption chiller fired by steam. The system was tested under different turbine loads, steam pressures and chiller outlet temperatures. An evaluation based on the 1st and 2nd Laws of Thermodynamics was also performed. For the ambient temperature around 24°C and microturbine at full load, the plant is able to provide 19 kW of saturated steam at 5.3 bar (161 °C), corresponding to 9.2 kW of refrigeration at -5 °C (COP = 0.44). From a 2nd law point-of-view, it was found that there is an optimal chiller outlet temperature that maximizes the chiller exergetic efficiency. As expected, the microturbine presented the highest irreversibilities, followed by the absorption chiller and the HRSG. In order to reduce the plant exergy destruction, it is recommended a new design for the HRSG and a new insulation for the exhaust pipe. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Climate change in tropical countries, like Brazil, causes major problems in dairy production due to an increase of heat stress effects. In recent years, milk production in Brazil increased 36.07%. The Southeast region remains a leader in production with herds of high producing Holstein cattle (mostly), which is more susceptible to heat stress. Thermal stress decreases fertility in direct and indirect ways. Conception rates are reduced of 40-60% during cooler months of the year and 10-20% in the warmer months. Negative effects of heat stress involve changes in reproductive hormones, follicular development, oocytes, and embryos, and decreased dry matter intake. Several studies discuss change in reproductive hormones, such as reduction in plasma concentration of GnRH, LH, and oestradiol, which lead to decreased detection of estrus and ovulation. Various methods are being studied to bypass these negative effects and increase the fertility of dairy cows under heat stress. Cooling systems are the most advantageous and can be associated with technologies such as ET and TAI

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The increased fuel economy and driveability of modern internal combustion engine vehicles (ICEVs) are the result of the application of advanced digital electronics to control the operation of the internal combustion engine (ICE). Microprocessors (and micro controllers) play a key role in the engine control, by precisely controlling the amount of both air and fuel admitted into the cylinders. Air intake is controlled by utilizing a throttle valve equipped with a motor and gear mechanism as actuator, and a sensor enabling the measurement of the angular position of the blades. This paperwork presents a lab setup that allows students to control the throttle position using a microcontroller that runs a program developed by them. A commercial throttle body has been employed, whereas a power amplifier and a microcontroller board have been hand assembled to complete the experimental setup. This setup, while based in a high-tech, microprocessor-based solution for a real-world, engine operation optimization problem, has the potential to engage students around a hands-on multidisciplinary lab activity and ignite their interest in learning fundamental and advanced topics of microprocessors systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the microtensile bond strength test (mu T), micromorphology of resin-enamel interface (RET) and etching patterns (EP) promoted by the etch-and-rinse adhesive, Prime&Bond NT (PB), and two self-etching adhesives, Clearfil SE Bond (SE) and Adper Prompt L-Pop (APR), to ground bovine enamel surfaces' when applied at temperatures of 5 degrees C (C), 40 degrees C (H) and 20 degrees C (R). Materials and Methods. Sixty-three bovine incisors were randomly divided into nine experimental groups (n=7) according to adhesive systems and temperatures. The buccal enamel surfaces were flattened with 600-grit SiC paper and abraded with a diamond bur under water-cooling. The adhesive systems were applied according to the manufacturer's instructions. After the restorative procedures, the specimens were sectioned into five slabs. Four slabs were prepared for mu T and one for interface analysis. For etching pattern analysis, the remaining 16 bovine enamel fragments were used (n=2). The adhesives were applied and the surfaces were rinsed with organic solvents after application. The specimens for RET and EP analysis were prepared for SEM analysis. Results. No significant differences among the adhesives were found at R temperature. However, at 5 degrees C, PB and APR presented lower bond strength than SE. At H temperature, higher bond strength was observed for PB than for APR and SE. At C and H temperature, formation of the interdiffusion zone was impaired and the treated enamel surfaces presented an undefined EP.