21 resultados para Energy purpose

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The sugar cane crop according to several authors can generate, besides the industrialized stalks, an amount of crop residues from the order of 15 to 30% in weight of the aerial part of the plants, depending on the field conditions. The sugar cane area in Brazil is around 5.5×106 hectares, with an amount of 400.106 tons of stalks, with stalks yield of 72 tons.ha-1 (Unica, 2005). This study took place in a sugar cane plot (Latitude 22°46'S, Longitude 47°23'W and 600m of altitude) with 3% of slope, located in São Paulo State. The sugar cane variety was SP 80-1816, in its forth cut, 11 months old and with a planted row spacing of 1.40m. By other side, several sugar mills are bringing the crop residue to their patio to produce energy with the bagasse. One way for that is the baling operation to bring the crop residue at the sugar mill. Some fundamental variables were obtained to define the best set of machines to work with in sugar cane crop residue removal in the baling system among the studied ones, some of the variables were: Soil Index (T1 = 0.83%, T2 = 0.46%, T3 = 0.65%, T4 = 0.57%); Energy Efficiency (T1 = 82.48%, T2 = 83.88%, T3 = 82.83% and T4 = 82.97%) of the system and Effective Cost for Equivalent Energy in US$.EBP-1 (T1 = 11.10, T2= 10.46, T3 = 11.47 and T4 = 10.57) of the baled trash delivered at the sugar mill.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper aims to analyze dual-purpose systems focusing the total cost optimization; a superstructure is proposed to present cogeneration systems and desalination technologies alternatives for the synthesis process. The superstructure consists of excluding components, gas turbines or conventional steam generators with excluding alternatives of supplying fuel for each combustion system. Also, backpressure or condensing/extraction steam turbine for supplying process steam could be selected. Finally one desalination unit chosen between electrically-driven or steam-driven reverse osmosis. multi-effect and multistage flash should be included. The analysis herein performed is based on energy and mass conservation equations, as well as the technological limiting equation of equipment. The results for ten different commercial gas turbines revealed that electrically-driven reverse osmosis was always chosen together with both natural gas and gasified biomass gas turbines. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents a methodology to analyze transient stability (first oscillation) of electric energy systems, using a neural network based on ART architecture (adaptive resonance theory), named fuzzy ART-ARTMAP neural network for real time applications. The security margin is used as a stability analysis criterion, considering three-phase short circuit faults with a transmission line outage. The neural network operation consists of two fundamental phases: the training and the analysis. The training phase needs a great quantity of processing for the realization, while the analysis phase is effectuated almost without computation effort. This is, therefore the principal purpose to use neural networks for solving complex problems that need fast solutions, as the applications in real time. The ART neural networks have as primordial characteristics the plasticity and the stability, which are essential qualities to the training execution and to an efficient analysis. The fuzzy ART-ARTMAP neural network is proposed seeking a superior performance, in terms of precision and speed, when compared to conventional ARTMAP, and much more when compared to the neural networks that use the training by backpropagation algorithm, which is a benchmark in neural network area. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Different secondary caries models may present different results. The purpose of this study was to compare different in vitro secondary caries models, evaluating the obtained results by polarized-light microscopy (PLM), scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). Standardized human enamel specimens (n = 12) restored with different materials (Z250 conventional composite resin-CRZ, Freedom polyacid-modified composite resin-CRF, Vitremer resin-modified glass-ionomer-GIV, and Fuji IX conventional glass-ionomer cement-GIF) were submitted to microbiological (MM) or chemical caries models (CM). The control group was not submitted to any caries model. For MM, specimens were immersed firstly in sucrose broth inoculated with Streptococcus mutans ATCC 35688, incubated at 37 degrees C/5% CO(2) for 14 days and then in remineralizing solution for 14 days. For CM, specimens were submitted to chemical pH-cycling. Specimens were ground, submitted to PLM and then were dehydrated, gold-sputtered and submitted to SEM and EDS. Results were statistically analyzed by Kruskall-Wallis and Student-Newman-Keuls tests (alpha = 0.05). No differences between in vitro caries models were found. Morphological differences in enamel demineralization were found between composite resin and polyacid-modified composite resin (CRZ and CRF) and between the resin-modified glass-ionomer and the glass-ionomer cement (GIF and GIV). GIF showed higher calcium concentration and less demineralization, differing from the other materials. In conclusion, the glass-ionomer cement showed less caries formation under both in vitro caries models evaluated. (C) 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 90B: 635-640, 2009

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Secondary caries is the main cause of direct restoration replacement. The purpose of this study was to analyze enamel adjacent to different restorative materials after in situ cariogenic challenge using polarized-light microscopy (PLM), scanning electron microscopy (SEM) and energy-dispersive X-ray analysis (EDS). Twelve volunteers, with a low level of dental plaque, a low level of mutans streptococci, and normal salivary flow, wore removable palatal acrylic appliances containing enamel specimens restored with Z250 composite, Freedom composite, Fuji IX glass-ionomer cement, or Vitremer resin-modified glass-ionomer for 14 days. Volunteers dripped one drop of 20% sucrose solution (n = 10) or distilled water (control group) onto each specimen 8 times per day. Specimens were removed from the appliances and submitted to PLM for examination of the lesion area (in mm(2)), followed by dehydration, gold-sputtering, and submission to SEM and EDS. The calcium (Ca) and phosphorus (P) contents were evaluated in weight per cent (%wt). Differences were found between Z250 and Vitremer, and between Z250 and FujiIX, when analyzed using PLM. Energy-dispersive X-ray analysis results showed differences between the studied materials regarding Ca %wt. In conclusion, enamel adjacent to glass-ionomer cement presented a higher Ca %wt, but this material did not completely prevent enamel secondary caries under in situ cariogenic challenge.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate in vitro the degree of marginal leakage in Class V cavities involving the cementoenamel junction. Cavities were 4 rum wide and 2 mm deep. The specimens received dentin pretreatment (37% phosphoric acid) followed by the Single Bond (3M) adhesive system application. The 40 specimens were then divided into four groups: Group I (control); Group 2 (Nd:YAG laser at 120 mJ/pulse, frequency of 10 Hz, power of 1.2 W); Group 3 (Nd:YAG laser at 140 mJ/pulse, frequency of 10 Hz, power of 1.4 W); Group 4 (Nd:YAG laser at 160 mJ/pulse, frequency of 10 Hz, power of 1.6 W). The cavities were restored with Z100 composite resin (3M) and light cured at 300-600 mW/cm(2) light intensity. Specimens were thermocycled to 500 cycles from 2-50 degrees C. After that, they were dried and sealed with nail varnish, respecting 1 mm around the restorations, and immersed in 0.5% methylene blue solution for 4 h. After this period, the teeth were rinsed, dried, sectioned, and analyzed in a stereoscopic loupe. The highest leakage scores were considered for each specimen. The results were statistically analyzed by the analysis of variance (ANOVA) Kruskal-Wallis test to the 5% level. For both the enamel and cementum, there was a decrease in marginal leakage with the application of laser energy; no significant differences were observed for Groups 2, 3, and 4. The results also showed a smaller tendency to marginal leakage on the cementum than on the enamel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to determine the rate of whole-body protein turnover in moderately and severely alcoholic, malnourished, cirrhotic patients fed with different amounts of protein or energy. Six male patients (Child classes B and C) and four age- and sex-matched healthy control subjects were studied for 18 d in fasting and feeding states; a single oral dose of [N-15]glycine was used as a tracer and urinary ammonia was the end product. The kinetic study showed that patients had higher protein catabolism while fasting (patients: 3.14 +/- 1.2 g of lean body mass/9 h; controls: 1.8 +/- 0.3 g of lean body mass/9 h: P<0.02). Although not statistically significant, protein catabolism (grams of lean body mass/9 h) was lower with the hyperproreic/hyperenergetic diet when compared with fasting. Nitrogen retention was consistent with the lower protein-catabolism rate; a statistically significant increase in nitrogen balance was observed when patients were fed with the hyperproteic/hyperenergetic diet compared with fasting 14.3 +/- 3.2 g of nitrogen/d and -2.2 +/- 1.9 g of nitrogen/d, respectively; P < 0.01). These data indicate that Child class B and C cirrhotic patients are hypercatabolic and that Long-term nutritional intervention with a hyperproteic/hyperenergetic diet is likely needed to improve their clinical and nutritional status. Nutrition 2001;17:239-242. (C) Elsevier B.V. 2001.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To determine whether a high energy dense diet intake increases oxidative stress and alters antioxidant enzymes in cardiac tissue. Design: A randomized, controlled study. Ninety-day-old female rats were randomly divided into two groups: one fed with a low energy dense diet (LE; 3.0 kcal g-1) and one with a high energy dense diet (HE; 4.5 kcal g-1). Materials and Methods: After 8 weeks of treatment, the animals were fasted overnight and sacrificed by decapitation. The serum was used for glucose, triacylglycerol, cholesterol, low-density lipoprotein (LDL)-cholesterol and high-density lipoprotein (HDL)-cholesterol determinations. The glycogen, lipoperoxide, lipid hydroperoxide, superoxide dismutase, glutathione peroxidase, lactate dehydrogenase, citrate synthase, total and non-protein sulphhydryl groups were determined in cardiac tissue. Results: HE decreased the myocardial glycogen content and increased the lactate dehydrogenase/citrate synthase ratio, indicating an increased glycolytic pathway and a shift from myocardial aerobic metabolism. HE-treated female rats showed increased lipoperoxide and hydroperoxide levels in cardiac tissue. Although no alterations were observed in the total sulphhydryl group and superoxide dismutase activities, glutathione peroxidase and the non-protein sulphhydryl group were significantly decreased in HE-treated animals. Conclusions: Although no alterations were observed in energy intake, HE induced an increased intake of fat and carbohydrate and an increased rate of weight gain. HE intake induced alterations in markers of oxidative stress in cardiac tissue. Hydrogen peroxide is an important toxic intermediate in the development of cardiac oxidative stress by HE. The specific nutrient content, such as fat and carbohydrate, rather than caloric intake, appears to be the main process inducing oxidative stress in HE-treated female rats.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To test if a water extract of Coleus barbatus (WEB) has any effect on weight gain, food energy utilization and lipid metabolism in young rats with obstructive cholestasis. METHODS: Forty 21 day old (P21) Wistar rats, in groups of 10, were submitted to one of the following treatments: a sham operation with daily water or WEB administration, double ligature and resection of the bile duct with daily water or WEB administration. At P49 they were submitted for euthanasia when the following were determined: ingested feed (IF), energy utilization (EU) and weight gain (WG) from P29 to P49, together with total serum cholesterol (TC) and triacylglycerol (TG) concentrations, liver wet weight (LWW) and fat content (LFC). Two Way ANOVA and the S.N.K. test for paired comparisons were employed to study the effects of cholestasis and those of WEB and their interactions (p < or = 0.05). RESULTS: Cholestasis, independently of WEB, and WEB, independently of cholestasis both reduced IF, EU, and WG but there was no significant interaction between the two factors. Cholestasis, independently of WEB, increased LWW, LFC, the TC and TG The WEB, independently of cholestasis, reduced these values, and there was a significant interaction between the two factors; such that these effects were more accentuated in animals with cholestasis. CONCLUSION: The WEB reduced IF, WG, and EU, both in the presence and absence of cholestasis in the same proportion. It also partially inhibited the increase in LWW, LFC, TC and TG caused by cholestasis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose - This paper seeks to address the issue of persistent and widespread drought conditions during 2000 and 2001, which were the apparent cause of the decline of water levels in the reservoirs of Brazilian hydroelectric power plants. Design/methodology/approach - This issue is addressed here through a case study of the hydroclimatology of the Paraíba river basin, in Southeast Brazil, home to four large multi-purpose operational reservoirs. Findings - The data analysis shows that neither changes in the frequency nor magnitude of extreme hydrological events (droughts and floods) nor in annual rainfall amounts can be detected from the existing climate record. The explanation is consistent with the fact that the terrestrial water and energy cycles are tightly, and non-linearly, coupled through evapotranspiration. Research limitations/implications - Therefore small change in the seasonality of rainfall can have a significant impact on the basin's overall hydrologic regime, and thus on the availability of water resources. Originality/value - Often, adaptation and resilience to climate variability are discussed in the context of catastrophic events such as floods and droughts. This study suggests that a different type of impacts, those associated with subtle, yet persistent changes of seasonality in the terrestrial water cycle, cannot be ignored in studies of long-term sustainability of water resources. © Emerald Group Publishing Limited.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The traditional operational and hazard control paradigm of an electrical installation has several issues pertaining to the diversity of equipment. A large maintenance inventory is a reason for concern for any manager, but the arc flash hazard is a particularly new phenomenon and the effects of equipment diversity on this phenomenon are even newer. The class of arc hazard can be increased, simply by changing the fuse link or circuit breaker manufacturer. Management pressure to operate as well as non-standard practices and installations are also partly responsible. The aim of this study is to take a typical situation in an industrial plant and to statistically simulate, by means of a dedicated software program, the fuse arc flash interruption performance of various manufacturers. The purpose of this study is to obtain a more objective indication of the influence of different fuse link manufacturers on arc flash incident energy. © 2011 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the analysis of some usual MPPT (Maximum Power Point Tracking) strategies intended for small wind energy conversion (up to 1kW) based on permanent magnet synchronous generators (PMSG), considering the stand-alone application for a novel buck-boost integrated inverter. Each MPPT method is analytically introduced and then it is simulated using MatLab/Simulink considering standard conditions of wind and also commercially available turbines and generators. The extracted power in each case is compared with the maximum available power, so the tracking factor is calculated for each method. Thus, the focus is on the application to improve the efficiency of stand-alone wind energy conversion systems (WECS) with battery chargers and AC load supplied by inverter. Therefore, for this purpose a novel single phase buck-boost integrated inverter is introduced. Finally, the main experimental results for the introduced inverter are presented. © 2011 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The traditional operational and hazard control paradigm of an electrical installation has several issues pertaining to the diversity of equipment. A large maintenance inventory is a reason for concern for any manager, but the arc-flash hazard is a particularly new phenomenon, and the effects of equipment diversity on this phenomenon are even newer. The class of arc hazard can be simply increased by changing the fuse link or circuit breaker manufacturer. Management pressure to operate as well as nonstandard practices and installations are also partly responsible. The aim of this article is to take a typical situation in an industrial plant and to statistically simulate, by means of a dedicated software program, the fuse arc-flash interruption performance of various manufacturers. The purpose of this article is to obtain a more objective indication of the influence of different fuse link manufacturers on arc-flash incident energy. © 1975-2012 IEEE.