47 resultados para Energy management systems

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a multi-agent system for real-time operation of simulated microgrid using the Smart-Grid Test Bed at Washington State University. The multi-agent system (MAS) was developed in JADE (Java Agent DEvelopment Framework) which is a Foundation for Intelligent Physical Agents (FIPA) compliant open source multi-agent platform. The proposed operational strategy is mainly focused on using an appropriate energy management and control strategies to improve the operation of an islanded microgrid, formed by photovoltaic (PV) solar energy, batteries and resistive and rotating machines loads. The focus is on resource management and to avoid impact on loads from abrupt variations or interruption that changes the operating conditions. The management and control of the PV system is performed in JADE, while the microgrid model is simulated in RSCAD/RTDS (Real-Time Digital Simulator). Finally, the outcome of simulation studies demonstrated the feasibility of the proposed multi-agent approach for real-time operation of a microgrid.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste trabalho foi caracterizar a variabilidade espacial da densidade do solo (Ds), teor de água no solo (θ) e porosidade total (Pt) em dois sistemas de manejo da colheita da cana-de-açúcar, com queima e sem queima, em um Latossolo Vermelho, na camada de 0-0,20 m. A área de estudo está localizada no município de Rio Brilhante-MS, na Usina Eldorado. A parcela de cada talhão apresentou malha com comprimento de 180 m e largura de 145,6 m, perfazendo 90 pontos distribuídos na forma de uma grade de nove colunas por dez linhas, com pontos distanciados 20 m de seu vizinho. Foram coletadas amostras de solo na camada de 0-0,20 m, nos anos agrícolas de 2007/2008 e 2008/2009. O sistema de colheita com queima apresentou maior densidade em relação ao mecanizado, nos dois períodos de análise. O teor de água no solo, assim como a porosidade, teve aumento proporcional com relação à diminuição da densidade do sistema de colheita com queima para com o mecanizado.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabalho teve por objetivo estudar os efeitos de diferentes sistemas de uso e manejo na densidade do solo nas suas propriedades químicas e na atividade microbiana em um Latossolo Vermelho distrófico (Oxisol). As amostras de solo foram retiradas de parcelas dos seguintes tratamentos: cerrado denso preservado, pastagem de Brachiaria decumbens degradada (20 anos), plantio direto com rotação de culturas (8 anos) e sistema convencional com rotação de culturas anuais (10 anos). O delineamento experimental utilizado foi o inteiramente casualizado, com dez repetições. O uso contínuo de plantio direto resultou em mais alta taxa de C-biomassa microbiana e menor perda relativa de carbono pela respiração basal, podendo determinar, desta forma, maior acúmulo de C no solo a longo prazo. Proporcionou, ainda, melhoria na densidade aparente e nas propriedades químicas do solo. Assim, o sistema plantio direto, com manejo de culturas, mostrou ser uma alternativa para a conservação e manutenção das condições físicas e do potencial produtivo de solos de cerrado.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O trabalho teve por objetivo estudar as modificações de atributos químicos de um Latossolo Vermelho após dois anos de manejo com adubação orgânica e/ou mineral com diferentes sistemas de cultivo. O experimento foi realizado na área experimental da Universidade Estadual Paulista - UNESP, localizada no município de Selvíria, Estado do Mato Grosso do Sul, no ano agrícola 2004/2005 e 2005/2006. Os tratamentos foram: cultivo convencional; cultivo mínimo e semeadura direta. As adubações foram: testemunha (sem adubação); adubação mineral (300 kg ha-1 da fórmula 20-00-20); adubação orgânica (esterco bovino - 20 Mg ha-1); adubação orgânica (esterco bovino) + ½ adubação mineral recomendada para a cultura utilizada; 20 e 30 Mg ha-1 de lodo de esgoto. em um ano foi utilizada a soja como cultura e no seguinte o sorgo. Avaliaram-se os atributos químicos do solo em quatro camadas. Os atributos químicos do Latossolo Vermelho foram modificados no primeiro ano após as adubações; a adubação com esterco, lodo de esgoto e a combinação do esterco+adubação mineral foram eficazes em modificar os atributos químicos do solo estudado; o lodo de esgoto foi mais eficaz na recuperação do P do solo e, a semeadura direta contribuiu para o aumento de K no solo

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper explains why the reliability assessment of energy limited systems requires more detailed models for primary generating resources availability, internal and external generating dispatch and customer demand than the ones commonly used for large power systems and presents a methodology based on the full sequential Montecarlo simulation technique with AC power flow for their long term reliability assessment which can properly include these detailed models. By means of a real example, it is shown how the simplified modeling traditionally used for large power systems leads to pessimistic predictions if it is applied to an energy limited system and also that it cannot predict all the load point adequacy problems. © 2006 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective this article is describe a methodology for the calculation of the profile of the electric field in the level soil and proximities originated by electric energy transmission systems real and in operation in the country. It also is commented the equation used and your computational implementation in order to agile and to optimize the studies. The results of simulations were just presented for the transmission system in the voltage class 500 kV for simplify the understanding and space restriction in the article, very although five others types of configurations have also been used in the complete study with very voltages and respective classes. The results were animating and very nearby of values well-known of electric field of other and publications traditional in the area. The graphic exits of program for better visual comprehension and understanding went in accomplished in the plan and in the space © 2010 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Soil is an essential resource for life and its properties are susceptible to be modified by tillage systems. The impact of management practices on soil functions can be assessed through a soil quality index. It is interesting to assess soil quality in different soil types. Therefore, the aim of this study was to determine the soil quality index of a Paleudult under different management conditions and sunflower culture. The experiment was carried out in Botucatu (SP, Brazil), in an 11-year non-tilled area used for growing soybean and maize during summer and black oat or triticale in winter. Four management systems were considered: no-tillage with a hoe planter (NTh), no-tillage with a double-disk planter (NTd), reduced tillage (RT) and conventional tillage (CT). Soil samples were taken from the planting lines at harvest time. To determine the soil quality indices, following the methodology proposed by Karlen and Stott (1994), three main soil functions were assessed: soil capacity for root development, water storage capacity of the soil and nutrient supply capacity of the soil. The studied Paleudult was considered a soil with good quality under all the observed management systems. However, the soil quality indices varied between treatments being 0.64, 0.68, 0.86 and 0.79 under NTh, NTd, RT and CT, respectively. Physical attributes such as resistance to penetration and macroporosity increased the soil quality index in RT and CT compared to NTh and NTd. The soil quality indices obtained suggested that the evaluated soil is adequate for sunflower production under our study conditions. In view of the SQI values, RT is the most suitable management for this site since it preserves soil quality and provides an acceptable sunflower yield. © 2011 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An important alteration of the equivalent loads profile has been observed in the electrical energy distribution systems, for the last years. Such fact is due to the significant increment of the electronic processors of electric energy that, in general, behave as nonlinear loads, generating harmonic distortions in the currents and voltages along the electric network. The effects of these nonlinear loads, even if they are concentrated in specific sections of the network, are present along the branch circuits, affecting the behavior of the entire electric network. For the evaluation of this phenomenon it is necessary the analysis of the harmonic currents flow and the understanding of the causes and effects of the consequent voltage harmonic distortions. The usual tools for calculation the harmonic flow consider one-line equivalent networks, balanced and symmetrical systems. Therefore, they are not tools appropriate for analysis of the operation and the influence/interaction of mitigation elements. In this context, this work proposes the development of a computational tool for the analysis of the three-phase harmonic propagation using Norton modified models and considering the real nature of unbalanced electric systems operation. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-conventional database management systems are used to achieve a better performance when dealing with complex data. One fundamental concept of these systems is object identity (OID), because each object in the database has a unique identifier that is used to access and reference it in relationships to other objects. Two approaches can be used for the implementation of OIDs: physical or logical OIDs. In order to manage complex data, was proposed the Multimedia Data Manager Kernel (NuGeM) that uses a logical technique, named Indirect Mapping. This paper proposes an improvement to the technique used by NuGeM, whose original contribution is management of OIDs with a fewer number of disc accesses and less processing, thus reducing management time from the pages and eliminating the problem with exhaustion of OIDs. Also, the technique presented here can be applied to others OODBMSs. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the analysis of some usual MPPT (Maximum Power Point Tracking) strategies intended for small wind energy conversion (up to 1kW) based on permanent magnet synchronous generators (PMSG), considering the stand-alone application for a novel buck-boost integrated inverter. Each MPPT method is analytically introduced and then it is simulated using MatLab/Simulink considering standard conditions of wind and also commercially available turbines and generators. The extracted power in each case is compared with the maximum available power, so the tracking factor is calculated for each method. Thus, the focus is on the application to improve the efficiency of stand-alone wind energy conversion systems (WECS) with battery chargers and AC load supplied by inverter. Therefore, for this purpose a novel single phase buck-boost integrated inverter is introduced. Finally, the main experimental results for the introduced inverter are presented. © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the operational analysis of the single-phase integrated buck-boost inverter. This topology is able to convert the DC input voltage into AC voltage with a high static gain, low harmonic content and acceptable efficiency, all in one single-stage. Main functionality aspects are explained, design procedure, system modeling and control, and also component requirements are detailed. Main simulation results are included, and two prototypes were implemented and experimentally tested, where its results are compared with those corresponding to similar topologies available in literature. © 2012 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Organizations often operate in turbulent environments characterized by intense competitiveness, constant technological progress, new market requirements, and scarce natural resources. This scenario imposes the constant need for change in the operation and companies' management. The integration of certifiable management systems is an effective alternative in this sense. The objective of the present study is to propose guidelines for the integration of the ISO 9001 Quality Management System (QMS), ISO 14001 Environmental Management System (EMS) and OHSAS 18001 Occupational Health and Safety Management System (OHSMS) in industrial companies. These guidelines were developed based on a theoretical framework and on the results from fourteen case studies performed in Brazilian industrial companies. The proposed guidelines were divided into three phases: A) integration planning, b) integration development, and c) integration control and improvement.