77 resultados para Energy demand
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The castor bean crop (Ricinus communis L.) has acquired prestige due to industries interest in the oil quality and recently for new sources of energy demand. The experiment that served as basis for the data used in this study was conducted at the Lageado Experimental Farm, in Botucatu - SP, 2008. This study aimed to avaluate the crop viability through energy balance and energy efficiency since the implantation until biodiesel production using parameters of consumption in operational management for installation and maintenance of culture harvest and oil production. The soil management operations, sow and harvest consumed the total of 266.20 MJ ha(-1), gathering with the fertilizers, pesticides, fuels, lubricants, labor, seed and industrial processing totaled 56,808 MJ ha(-1) of energy inputs. The energy production was 72,814.00 MJ ha(-1). The industry still lacks studies thal would contribution data collection and more specific energy coefficients. The castor beans cultivation was considered efficient allowing again of 15983.44 MJ ha(-1) equivalent to about 415 liters of diesel oil.
Resumo:
The generation expansion planning (GEP) problem consists in determining the type of technology, size, location and time at which new generation units must be integrated to the system, over a given planning horizon, to satisfy the forecasted energy demand. Over the past few years, due to an increasing awareness of environmental issues, different approaches to solve the GEP problem have included some sort of environmental policy, typically based on emission constraints. This paper presents a linear model in a dynamic version to solve the GEP problem. The main difference between the proposed model and most of the works presented in the specialized literature is the way the environmental policy is envisaged. Such policy includes: i) the taxation of CO(2) emissions, ii) an annual Emissions Reduction Rate (ERR) in the overall system, and iii) the gradual retirement of old inefficient generation plants. The proposed model is applied in an 11-region to design the most cost-effective and sustainable 10-technology US energy portfolio for the next 20 years.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A subsolagem é uma das operações mecanizadas de elevado custo e demanda energética por área, tradicionalmente utilizada pelos agricultores antes do preparo do solo na descompactação de camadas adensadas. Este trabalho teve como objetivo avaliar a demanda energética na operação de subsolagem realizada antes e depois de diferentes sistemas de preparo periódico num solo classificado como Nitossolo Vermelho Distroférrico. Os sistemas de preparo periódico foram: aração com discos; aração com discos mais uma gradagem de nivelamento; grade aradora; grade aradora mais gradagem de nivelamento e escarificação. O trator utilizado como fonte de potência no experimento foi um Valmet 128 (4x2tda). A demanda energética por área foi menor na subsolagem realizada depois do preparo periódico do solo, proporcionando uma economia de 21,9%. A realização da subsolagem depois do preparo periódico do solo resultou numa diminuição da exigência de força de tração em 21,1% e da potência disponível na barra de tração em 15%.
Resumo:
Foi avaliado o consumo energético das operações mecanizadas envolvidas na produção de silagem de planta inteira e silagem de grão úmido de milho, tendo como referência o processamento seco desse cereal. O ensaio foi conduzido na Fazenda Experimental Lageado, pertencente à Faculdade de Ciências Agronômicas, e nas instalações da Faculdade de Medicina Veterinária e Zootecnia - UNESP, localizada no município de Botucatu - SP. O delineamento experimental foi em blocos ao acaso, com parcelas subdivididas no tempo (três épocas de colheita: silagem de planta inteira, silagem de grão úmido e colheita de grãos secos), com 10 repetições. As análises estatísticas foram realizadas por meio do programa ESTAT, pelo teste de média de Tukey, a 5% de probabilidade. A silagem de planta inteira teve o maior consumo de combustível por área. A secagem dos grãos de 15,5% para 13% foi responsável por 87% do gasto de energia por área. A silagem de grão úmido demandou o menor uso de energia por área nas operações mecanizadas.
Resumo:
Both the inadequate use and the ignorance of the different soil tillage implements available in the home market has become one of the leading motives of failures, related to soil and water conservation. The periodical tillage is traditionally utilized after subsoiling for soil clod breaking, leveling and residue incorporation. This work aimed to evaluate the energy requirement for different periodical soil tillage systems performed before and after subsoiling in a soil classified as Distroferric Red Nitosol. The periodic tillage systems were: disk plowing; disk plowing plus one leveling harrowing; disk harrow; disk harrow plus leveling harrowing stirring. The experimental design was a 5x2 factorial scheme with 5 completely randomized blocks. The results show that the periodic soil preparation systems based on disks have better energy efficiency when performed before the operation of subsoiling. The system of soil preparation with harrowing obtained the lower energy demand, in relation to other periodic soil preparation systems, when done after subsoiling.
Resumo:
Os biodigestores têm sido objetos de grande destaque devido a atual crise de energia e conseqüente busca de fontes alternativas. Outro fator que coloca os biodigestores em evidência é o intenso processo de modernização da agropecuária, que além da grande demanda de energia, produz um volume de resíduos animais e de culturas, que ocasiona muitas vezes problemas de ordem sanitária. O objetivo deste trabalho é fornecer uma ferramenta matemática para determinação de parâmetros para projetos de construção de biodigestores rurais, levando-se em consideração o atendimento de necessidades energéticas, obedecendo os dimensionamentos dos sistemas, fatores de rendimento e garantindo a funcionalidade. Para isto, foram formulados modelos de otimização não lineares, de fácil resolução, para os três principais tipos de biodigestores rurais. Com a resolução destes modelos são determinados a altura e o diâmetro que levem a um volume mínimo para cada tipo, com isto reduz-se a quantidade necessária de materiais de alvenaria e consequentemente o custo do biodigestor é diminuído.
Resumo:
With the large penetration of the natural gas into the Brazilian energy structure, industries such as paper mills and chemical plants are analyzing the feasibility of implementing cogeneration schemes appropriate to this fuel. The analysis of the energy demand patterns of a chemical company from the photographic sector revealed the possibility of using combined cycles or diesel engine cogeneration schemes keeping the existing compression refrigeration units and steam or gas cycle cogeneration systems with absorption refrigeration units. In terms of economic attractiveness, an analysis based on the method of the internal rate of return was performed. The results indicated that the schemes composed by reciprocating engines and combined cycle with compression chillers, as well as the gas cycle scheme with absorption chiller, present return periods of up to 3 years, showing that the investment in cogeneration could be of interest for this plant. (C) 2000 Elsevier B.V. Ltd. All rights reserved.
Resumo:
1. To determine whether diltiazem protects the hypoxic myocardium by reducing contractile work, we have compared the effects of diltiazem and quiescence on left ventricular (LV) papillary muscle subjected to hypoxia. Papillary muscles were obtained from male Charles River CD rats weighing 150-250 g.2. Four groups of muscles were studied: control (N = 6), non-stimulation (N = 10), diltiazem 10(-4) M (N = 6) and diltiazem 10(-4) M plus non-stimulation (N = 10).3. Isolated mt LV papillary muscles were studied in Krebs-Henseleit solution with a calcium concentration of 2.52 mM at 28-degrees-C while contracting isometrically at a stimulation rate of 0.2 Hz. Resting tension and active isometric tension were measured.4. Both diltiazem and quiescence significantly attenuated contracture tension during hypoxia (0.91 +/- 0.10 vs 2.26 +/- 0.49 g/mm2 for diltiazem vs control, and 0.55 +/- 0.18 vs 2.26 +/- 0.49 g/mm2 for quiescence vs control). Recovery of active tension was improved in the diltiazem groups during reoxygenation (4.16 +/- 0.42 vs 3.75 +/- 0.51, 3.53 +/- 0.15 vs 2.90 +/- 0.13, 5.84 +/- 0.33 vs 6.48 +/- 0.29 and 5.98 +/- 0.90 vs 7.67 +/- 0.68 g/mm2 for diltiazem, diltiazem non-stimulation, non-stimulation and control groups).5. The results suggest that the protective effect of diltiazem during hypoxia was due to the reduction in energy demand of the myocardium.
Resumo:
Thyroid hormone is known to affect myocardial glycogen stores and thereby possibly limit anaerobic performance of mammalian cardiac muscle. Thyroid hormone administration (3,5,T-triiodo-L-thyroxine, 300 mu g/kg/day, sc) for 10 days decreased left ventricle (LV) glycogen concentration relative to euthyroid animals (2.78 +/- 0.46 vs. 4.28 +/- 0.29 mg/g of LV (mean +/- SEM)) while increasing the percent of V(1) myosin isozyi-ne, contractile activity and cardiac mass. In contrast, thyroidectomy increased myocardial glycogen stores (8.50 +/- 0.56 mg/g of LV) and shifted the myosin isozyme toward V(3), prolonged contractile activity and decreased LV mass. Thyroxine administration for 3, 7 and 10 days to thyroidectomized animals progressively decreased contractile duration and increased LV mass. Thyroxine administration for 3 or 7 days to thyroidectomized rats did not reduce glycogen stores (7.75 +/- 1.02 and 9.62 +/- 1.16 mg/g of LV, respectively), whereas myocardial glycogen declined to 3.30 +/- 0.58 mg/g of LV after 10 days of treatment. During hypoxia, cardiac muscle from thyroidectomized rats maintained greater active force and developed less contracture relative to euthyroid and, to a greater extent, than hyperthyroid rats. Removal of glucose from the bath decreased anaerobic performance and impaired recovery; however, myocardium from thyroidectomized rats remained more tolerant to hypoxia than the euthyroid group. Overall, the intrinsic LV glycogen content was positively correlated to anaerobic performance. These data demonstrate that the thyroid state profoundly affects myocardial growth, contractility and anaerobic performance of rat myocardium. Although energy demand may affect function during hypoxia, anaerobic substrate reserve (cardiac glycogen concentration) appears to be the primary factor determining tolerance to hypoxic stress. J. Exp. Zool. 311A:399-407, 2009. (C) 2009 Wiley-Liss, Inc.
Resumo:
In this paper we present technical and economic studies of cogeneration systems utilizing combustion engines and gas turbines, applied in two establishments of the tertiary sector, regarding Brazilian conditions (according to Silveria, 1994). In the first step cogeneration systems utilizing combustion engines associated to absorption refrigeration systems are studied, in which electricity and cold air for a university building rate produced. In the second step some possibilities of the use of the gas turbine in cogeneration systems for a hospital are shown. In this case, the exhaust gases are utilized for the production of steam in a heat recovery steam generator (HRSG) or cold water in an absorption refrigeration system (for air conditioning) for the hospital building. The dynamic increment of the energy demand of Brazilian tertiary sector in last years can increase the installation of these cogeneration system (in compact version) as well as strengthen the development of the decentralized energy generation in Brazil.
Resumo:
This paper presents the results of a numerical and experimental study of phase change material (PCM) filled walls and roofs under real operational conditions to achieve passive thermal comfort. The numerical part of the study was based on a one-dimensional model for the phase change problem controlled by pure conduction. Real radiation data was used to determine the external face temperature. The numerical treatment was based upon using finite difference approximations and the ADI scheme. The results obtained were compared with field measurements. The experimental set-up consisted of a small room with movable roof and side wall. The roof was constructed in the traditional way but with the phase change material enclosed. Thermocouples were distributed across the cross section of the roof. Another roof, identical but without the PCM, was also used during comparative tests. The movable wall was also constructed as is done traditionally but with the PCM enclosed. Again, thermocouples were distributed across the wall thickness to enable measurement of the local temperatures. Another wall, identical but without the PCM, was also used during comparative tests. The PCM used in the numerical and experimental tests was composed of a mixture of two commercial grades of glycol in order to obtain the required fusion temperature range. Comparison between the simulation results and the experiments indicated good agreement. Field tests also indicated that the PCM used was adequate and that the concept was effective in maintaining the indoor temperature very close to the established comfort limits. Further economical analysis indicated that the concept could effectively help in reducing the electric energy consumption and improving the energy demand pattern. © 1997 by John Wiley & Sons, Ltd.
Resumo:
The current technological development made by the absorption refrigeration system is an economic and ambient alternative in comparison to the vapor cycle, possessing an advantage that uses thermal energy that is less noble. Chillers of absorption are used widely in the air conditioned industries, because they can be set in motion through hot water vapors that burn natural gas, solar energy, biomasses amongst others instead of electricity. These systems allow it to reduce the tips of electric demand and balance the rocking of energy demand. This work has had a main objective to simulate a absorption refrigeration cycle with lithium-water bromide solution using biogas of sanitary landfill, and mixtures of this with natural gas. These results shown to the energy viability of the system burning biogas and its mixtures with natural gas in the generator, when compared with equipments that uses traditional fuels (natural gas, oil diesel, amongst others), for operation the commercial chillers with 15 kW of the refrigeration capacity and temperature of the water in the entrance of 14°C and the exit of 7°C.
Resumo:
Running economy (RE), defined as the energy demand for a given velocity of submaximal running, has been identified as a critical factor of overall distance running performance. Plyometric and resistance trainings, performed during a relatively short period of time (15-30 days), have been successfully used to improve RE in trained athletes. However, these exercise types, particularly when they are unaccustomed activities for the individuals, may cause delayed onset muscle soreness, swelling, and reduced muscle strength. Some studies have demonstrated that exercise-induced muscle damage has a negative impact on endurance running performance. Specifically, the muscular damage induced by an acute bout of downhill running has been shown to reduce RE during subsequent moderate and high-intensity exercise (>65% VOax). However, strength exercise (i.e., jumps, isoinertial and isokinetic eccentric exercises) seems to impair RE only for subsequent high-intensity exercise (90% VOax). Finally, a single session of resistance exercise or downhill running (i.e., repeated bout effect) attenuates changes in indirect markers of muscle damage and blunts changes in RE. © 2013 Cláudio de Oliveira Assumpção et al.