155 resultados para Electron and confocal microscopy
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Background Damage to the corneal epithelium causes not only a reaction for its repair but also affects other parts of the cornea as well as different components of the anterior segment of the eye. The purpose of this investigation was to analyze the consequences, following epithelial and limbal damage, to the iris of rabbits (Oryctolagus cuniculus).Methods The corneal epithelium was thoroughly scraped followed by surgical excision of the limbus. Next, (3)H-thymidine ((3)H-TdR) was injected intravitreally both into the right (experimental) and left (control) eyes which had their anterior segments processed for autoradiography at intervals of 2, 7 and 21 days after surgery (three rabbits per interval). The irises were also examined with scanning-electron and confocal microscopy after Evans blue injection.Results There was a high frequency of labeling in the cells of the iris blood vessels in the experimental eye, particularly the endothelial ones. The ratio of labeled cells between experimental and control irises was 40:1, with a population of nuclei increasing by 25% and remaining labeled up to 21 days. There was also an increase in the volume of the iris vasculature as shown by confocal microscopy. The high labeling frequencies of the vascular cells were observed throughout the iris from the ciliary to the pupillary regions.Conclusions The lesions on the corneal epithelium elicit proliferation of the iris vascular cells, mainly its endothelium, as well as an early breakdown of the blood-aqueous barrier. The daughter cells resulting from the damage to the eye surface were detected up to 21 days after a single injection of (3)H-TdR, most likely due to their slow turnover. As a consequence of this proliferation, the vasculature of the iris increased in volume.
Resumo:
This study aimed to evaluate the effect of Er:YAG (L) and diamond drills (DD) on: 1) the microshear bond strength (MPa); 2) the adhesive interface of two-step (TS) – Adper Scotchbond Multipurpose and one-step (OS) adhesives – Adper EasyOne, both from 3M ESPE. Material and methods: According to the preparation condition and adhesives, the samples were divided into four groups: DD_TS (control); DD_OS; L_TS and L_OS. 60 bovine incisors were randomly divided into experimental and groups: 40 for microshear bond strength (n = 10) and 20 for the adhesive interface morphology [6 to measure the thickness of the hybrid layer (HL) and length of tags (t) by CLSM (n = 3); 12 to the adhesive interface morphology by SEM (n = 3) and 2 to illustrate the effect of the instruments on dentine by SEM (n = 1)]. To conduct the microshear bond strength test, four cylinders (0.7 mm in diameter and 1 mm in height with area of adhesion of 0.38 mm) were constructed with resin composite (Filtek Z350 XT – 3M ESPE) on each dentin surface treated by either L or DD and after adhesives application. Microshear bond strength was performed in universal testing machine (EMIC 2000) with load cell of 500 kgf and a crosshead speed of 0.5 mm / min. Adhesive interface was characterized by thickness of hybrid layer (HL) and length of tags (t) in nm, with the aid of UTHSCSA ImageTool software. Results: Microshear bond strength values were: L_TS 34.10 ± 19.07, DD_TS 24.26 ± 9.35, L_OS 33.18 ± 12.46, DD_OS 21.24 ± 13.96. Two-way ANOVA resulted in statistically significant differences only for instruments (p = 0.047). Mann-Whitney identified the instruments which determined significant differences for HL thickness and tag length (t). Concerning to the adhesive types, these differences were only observed for (t). Conclusion: It can be concluded that 1) laser Er:YAG results in higher microshear bond strength values regardless of the adhesive system (TS and OS); 2) the tags did not significant affect the microshear bond strength; 3) the adhesive interface was affected by both the instruments for cavity preparation and the type of adhesive system used.
Resumo:
We have studied the possibility of associating fluorescence microscopy and hematoxylin-eosin staining for the identification of elastic fibers in elastin-rich tissues. Elastic fibers and elastic laminae were consistently identified by the proposed procedure, which revealed itself to be easy and useful for the determination of such structures and their distribution. The fluorescence properties of stained elastic fibers are due to eosin staining as revealed by fluorescence analysis of the dye in solution, with no or only minor contribution by the elastin autofluorescence. The main advantage of this technique resides in the possibility of studying the distribution of elastic fibers in file material without further sectioning and staining. The use of the confocal laser scanning microscope greatly improved the resolution and selectivity of imaging elastic fibers in different tissues. The determination of the three-dimensional distribution and structure of elastic fiber and laminae using the confocal laser scanning microscope was evaluated and also produced excellent results.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Introduction The aim of this study was to compare the effect of QMix, BioPure MTAD, 17 % EDTA, and saline on the penetrability of a resin-based sealer into dentinal tubules using a confocal laser scanning microscope (CLSM) and to describe the cleaning of root canal walls by SEM. Methods Eighty distobuccal roots from upper molars were selected and randomly divided into four groups (n=20) before root canal preparation according to the solution used in the final rinse protocol (FRP): QG (QMix), MG (BioPure MTAD), EG (17 % EDTA), and CG (control group: saline). Ten roots of each group were prepared for SEM, and images (×2000) from the canal walls were acquired. The remaining canals were filled with a single gutta-percha cone and AH Plus with 0.1 % Rhodamine B. The specimens were horizontally sectioned at 4 mm from the apex, and the slices were analyzed in CLSM (×10). Sealer penetration was analyzed with Adobe Photoshop software. Results QG and EG presented similar amounts of sealer penetration (P>.05). MG and CG presented the lowest penetrability values (P<.05). The best results for smear layer removal of the apical third of the root canal were achieved by the QG and EG groups when compared with MG and CG (P<.05). Conclusions Seventeen percent EDTA and QMix promoted sealer penetration superior to that achieved by BioPure MTAD and saline. Clinical relevance Despite studies have not confirmed the relationship between sealing ability of endodontic sealers and their penetration in dentinal tubules, sealer penetration assumes importance, since endodontic sealers, unlike guttapercha, are able to penetrate in dentinal tubules, isthmus, and accessory canals, filling the root canal system.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This Letter describes the search for a new heavy charged gauge boson W-' decaying into an electron and a neutrino. The data were collected with the D0 detector at the Fermilab Tevatron p (p) over bar Collider at root s=1.96 TeV, and correspond to an integrated luminosity of about 1 fb(-1). Lacking any significant excess in the data in comparison with known processes, an upper limit is set on sigma(')(W)xB(W-'-> e nu), and a W-' boson with mass below 1.00 TeV can be excluded at the 95% C.L., assuming standard-model-like couplings to fermions. This result significantly improves upon previous limits and is the most stringent to date.
Resumo:
This paper develops a framework for the interpretation of ionic insertion/deinsertion reactions in an aqueous environment taking place in transition-metal hexacyanoferrates of the general formula KhFek3+ [Fe2+ (CN)(6)](l)center dot mH(2)O, also called Prussian Blue. Three different processes were fully separated in the electrochemistry of these films. It was clearly identified that one of these electrochemical processes involves the insertion/deinsertion of H3O+ (hydrated protons) through the channels of the KhFek3+ [Fe2+ (CN)(6)](l) center dot mH(2)O structure to reach the film electroneutrality during the electron transfer between Everitt's Salt and Prussian Blue. The other electrochemical processes involve K+ or H+ (proton) exchange through the water crystalline structure existing in the channels of the KhFek3+ [Fe2+(CN)(6)](l)center dot mH(2)O structure.
Resumo:
The pattern of availability of free DNA phosphates, and the kind of DNA-protein complex arrangement, both induced by nuclear basic proteins, and the richness in arginine residues in these proteins were investigated cytochemically and cytophysically in spermatozoa of the South-American Hylidae species, Hyla fuscovaria and Hyla biobeba. The aim was to demonstrate differences at the level of sperm histones in two species of Hyla until recently considered to be congeneric. The results indicated differences in the spermatozoal nuclear basic proteins and DNA-protein complexes when the two species were compared. The spermatozoa of Hyla biobeba were assumed to be likely to contain a Bloch's ''type 3'' protein type (intermediate sperm basic protein), similarly to Hyla species of North and Central America. on the other hand, the data obtained for the spermatozoa of Hyla fuscovaria indicated that they contain a protamine or protamine-like protein, differing from Hyla biobeba and Hyla species of North and Central America. It is suggested that the differences reported here may be genus-specific, since Hyla fuscovaria has recently been reclassified as Scinax fuscovaria based on parameters other than sperm histone types. These findings are in agreement with the general view of a wide variability in sperm nuclear proteins in the Anura group.