56 resultados para Electromyographic signal acquisition
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The alternate current biosusceptometry (ACB) is a biomagnetic technique used to study some physiological parameters associated with gastrointestinal (GI) tract. For this purpose it applies an AC magnetic field and measures the response originating from magnetic marks or tracers. This paper presents an equipment based on the ACB which uses anisotropic magnetoresistive (AMR) sensors and an inexpensive electronic support. The ACB-AMR developed consists of a square array of 6x6 sensors arranged in a firstorder gradiometer configuration with one reference sensor. The equipment was applied to capture magnetic images of different phantoms and to acquire gastric contraction activity of healthy rats. The results show a reasonable sensitivity and spatial-temporal resolution, so that it may be applied for imaging of phantoms and signal acquisition of the GI tract of small animals. © 2010 IEEE.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: To identify the electromyographic fatigue threshold in the erector spinae muscle. Methods: Eight 19 to 24-year-old male volunteers participated in this study, in which surface electrodes were used, as well as a biological signals acquisition module (Lynx) with a sampling frequency of 1000Hz, a 1000 times gain, a 20Hz high pass filter and a 500Hz low pass filter. The test consisted of repeated isometric contractions of the erector spinae muscle in a 45° hip flexion posture, with 30%, 40%, 50% and 60% of the maximum voluntary isometric contraction. Results: A positive correlation of the RMS (root mean square) value as a function of time was found for most of the subjects with 40% (N = 6), 50% (N = 7) and 60% (N = 8) loads of the maximum voluntary isometric contraction. Conclusions: It was concluded, from this study, that the proposed protocol provides evidence, through the electromyographic signal, of the development of fatigue in the erector spinae muscle with loads of 40%, 50% and 60% of the maximum voluntary isometric contraction. The protocol also allows the electromyographic fatigue threshold and its probable applicability in the diagnosis of this phenomenon during repetitive activities to be determined.
Resumo:
The effective activity of the pectoralis major and deltoideus anterior muscles in horizontal flyer exercises with external loads of 25, 50, 75 and 100% of the maximum load was studied in 11 male volunteers. The electromyographic analysis was done by using MEDI-TRACE-200 surface electrodes connected to a biological signal acquisition mode coupled to a PC/AT computer. The electromyographic signals were processed and the values obtained were normalized through maximum voluntary isometric contraction. It was statistically observed that in all types and loads of this exercise, the muscles presented significant differences in the concentric and eccentric phases. In the concentric phase, when different loads were compared, the muscles were more active with 75 and 100% of the maximum load, while in the eccentric phase, higher activity was observed with 100% of the maximum load. By analyzing each load effect in the concentric phase, it was verified that the muscles on the left side were more active than those on the right side with 25, 75 and 100% of the maximum load.
Resumo:
The objective of this study was to analyze the electromyographic (EMG) signal behavior of rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL) and biceps femoris (caput longum) (BFCL) from nine women during fatiguing dynamic and isometric knee extensions tests and to determine their EMGFT (Electromyographic Fatigue Threshold). Surface electrodes, biological signal acquisition module, analogical-digital converter board and specific software were used. The RMS (Root Mean Square) values obtained from concentric phase (80 to 30 degrees) of the dynamic knee extension andfrom isometric contraction were correlated with time on each load by linear regression analysis. The respective slopes were correlated with the correspondent load to determine the EMGFT. Force (Kgf) and median frequency - MF (Hz) obtained during MIVC (Maximal Isometric Voluntary Contraction) performed before and after the fatiguing tests were calculated in Matlab environment. The results demonstrated that the endurance time decreases with higher loads the EMG amplitude increase with time and was greater at higher loads, between muscles in dynamic exercise the RF and VL showed higher slopes, and in isometric exercise the VL showed the same behavior The EMGFT values were similar in both exercises; the force values predominantly decreased after fatiguing tests; however the MF only decreased after some loads. The protocols proposed allowed standardizing protocols at least to induce the fatigue process and to determine the EMGFT as an endurance indicative, which may be used to evaluate the effectiveness of rehabilitative or training interventions indicated to reduce muscle weakness and fatigue.
Resumo:
Due to a shortage of textbooks with specific data on muscular activity concerning physical conditioning and sports, we analysed electromyographically the muscles pectoralis major and deltoideus anterior, bilaterally, in inclined flying exercises, during the concentric and eccentric phases, with external loads of 25, 50, 75 and 100% of the maximum load. The electromyographic analysis was performed in eleven male volunteers with MEDITRACE-200 surface electrodes connected to a six-channel biologic signal acquisition module coupled to a PC/AT computer. The electromyographic signals were processed and the obtained effective values were normalized through maximum voluntary isometric contraction. Statistically, the results showed that all the muscles studied presented significant differences between the concentric and the eccentric phases, with higher electromyographic activity during the concentric phase. By analysing the different loads for each muscle in both phases, significant electromyographic activity was observed for all muscles. When the effect of each load on each muscle during the concentric phase was analysed, it was noticed that the muscles on the left were more active than those on the right side, while in the eccentric phase the muscles had different behavior.
Resumo:
The effects of occlusal splint on the electric activity of masseter were studied in 15 women who presented sleep bruxism using surface electromyography. Sleep bruxism was defined by its clinical characteristics. The signal acquisition was done during mandible occlusion without clenching and maximum voluntary contraction in two situations. The first was after a workday without using the occlusal splint; and the second, after a sleeping night using occlusal splints. Evaluating masseter muscles during mandible occlusion without clenching, it could be observed that lower values were noticed after splint wearing in both sides. The same results were verified in maximum voluntary contraction (MVC). These results confirmed that the use of occlusal splints reduced the electromyographic activity of the right and left masseters, showing its myorelaxing effect. © 2009 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The rectus femoris was analysed in 10 volunteers during knee flexion and extension with the feet in normal, plantar flexion and dorsal flexion positions. Hewlett-Packard surface electrodes, an electromyographic signal amplifier, a computer equipped with an A/D conversion plaque (Model CAD 10/26), software specially designed to record and analyse the signals, Horizontal Leg Press, and electrogoniometers were used. The rectus femoris muscle showed strong potentials at the beginning of knee extension. In the simultaneous bendings of the knee and hip the activity was strong toward the end of the movement. The rectus femoris showed a similar activity both in the upper and lower platforms. As for foot positions, the rectus femoris showed the smallest potentials with the foot in plantar flexion and the largest ones with the foot in dorsal flexion.
Resumo:
The gastrocnemius was analysed in 10 male volunteers during knee flexion and extension with the foot in normal, plantar flexion and dorsal flexion positions. Hewlett-Packard surface electrodes, an electromyographic signal amplifier, a computer equipped with an AID conversion plaque (Model CAD 10/26), a software specially designed to record and analyse the signals, a horizontal leg press, and electrogoniometers were used. The gastrocnemius muscle showed strong potentials at the end of knee extension and beginning of knee flexion. The muscle presented a similar activity both in the zipper and lower platforms. As to bilateral action, the right gastrocnemius presented stronger potentials on the upper platforms, whereas the potentials were bilaterally similar on the lower platforms. As for foot position, the gastrocnemius presented strong potentials when the foot was in plantar flexion. The remaining positions had no effect on the work of the muscle.
Resumo:
The double pulley equipment was tested on ten male volunteers during contraction of the semitendinosus and biceps femoris (caput longum) muscles in the following movements of the lower limbs: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. The myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. The semitendinosus and biceps femoris muscles presented the highest potentials in movements 1; 2; 7, 8 and 9, whereas the potentials in the remaining movements were negligible. The pattern of activity of the semitendinosus and the biceps femoris was similar in exercises 1, 2, 3, 4 and 8. The potentials of the semitendinosus prevailed in movements 5, 6 and 7, and the strongest potentials observed in movement 9 were those of the biceps femoris.
Resumo:
Alteration of the occlusion and the position of the jaw can affect the muscles of the neck, due to a relationship between the masticatory and cervical systems. Thus, the objective of this study was to verify whether the bite in maximal clenching effort, in centric occlusion, in individuals with clinically normal occlusion, and without a history of dysfunction in the masticatory system, influences the electromyographic activity of the upper trapezius muscle. A total of 19 normal individuals participated in the study, 14 of which were women (average age of 25.4 ± 4.14 years), and 5 were men (average age of 24.11 ± 3.28 years). The root mean square (RMS) amplitude and median frequency (MF) of the upper trapezium muscle with 40% and 60% of maximal voluntary contraction were analyzed under pre- and post-maximal clenching effort conditions in centric occlusion. The electromyographic signal was collected with a sampling frequency of 2. kHz and the value in RMS was obtained by a moving window of 200. ms. The paired Student's t-test was used to compare RMS amplitude and MF under pre- and post-maximal clenching effort conditions. The level of significance for each comparison was set to p<0.05. This study concluded that in individuals without a history of dysfunction of the masticatory system, maximum clenching effort in centric occlusion does not alter the electromyographic signal of the upper trapezius. © 2009 Elsevier Ltd.
Atividade elétrica muscular e medida da força externa nos membros superiores de indivíduos saudáveis
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)