123 resultados para Electric wire

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Three-phase three-wire power flow algorithms, as any tool for power systems analysis, require reliable impedances and models in order to obtain accurate results. Kron's reduction procedure, which embeds neutral wire influence into phase wires, has shown good results when three-phase three-wire power flow algorithms based on current summation method were used. However, Kron's reduction can harm reliabilities of some algorithms whose iterative processes need loss calculation (power summation method). In this work, three three-phase three-wire power flow algorithms based on power summation method, will be compared with a three-phase four-wire approach based on backward-forward technique and current summation. Two four-wire unbalanced medium-voltage distribution networks will be analyzed and results will be presented and discussed. © 2004 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work describes a methodology for power factor control and correction of the unbalanced currents in four-wire electric circuits. The methodology is based on the insertion of two compensation networks, one wye-grounded neutral and another in delta, in parallel to the load. The mathematical development has been proposed in previous work [3]. In this paper, however, the methodology was adapted to accept different power factors for the system to be compensated. on the other hand, the determination of the compensation susceptances is based on the instantaneous values of the load currents. The results are obtained using the MatLab - Simulink environment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work describes a methodology for power factor control and correction of the unbalanced currents in four-wire electric circuits. The methodology is based on the insertion of two compensation networks, one wye-grounded neutral and other in delta, in parallel to the load. The mathematical development has been proposed in previous work [3]. In this paper, however, the determination of the compensation susceptances is based on the instantaneous values of load currents. The results are obtained using the MatLab-Simulink enviroment

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In some applications like fault analysis, fault location, power quality studies, safety analysis, loss analysis, etc., knowing the neutral wire and ground currents and voltages could be of particular interest. In order to investigate effects of neutrals and system grounding on the operation of the distribution feeders with faults, in this research a hybrid short circuit algorithm is generalized. In this novel use of the technique, the neutral wire and assumed ground conductor are explicitly represented. Results obtained from several case studies using IEEE 34-node test network are presented and discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigates the major similarities and discrepancies of three important current decompositions proposed for the interpretation of unbalanced and/or non linear three-phase four-wire circuits. The considered approaches were the so-called FBD Theory, the pq-Theory and the CPT. Although the methods are based on different concepts, the results obtained under ideal conditions (sinusoidal and balanced signals) are very similar. The main differences appear in the presence of unbalanced and non linear load conditions. It will be demonstrated and discussed how the choice of the voltage referential and the return conductor impedance can influence in the resulting current components, as well as, the way of interpreting a power circuit with return conductor. Under linear unbalanced conditions, both FBD and pq-Theory suggest that the some current components contain a third-order harmonic. Besides, neither pq-Theory nor FBD method are able to provide accurate information for reactive current under unbalanced and distorted conditions, what seems to be done by means of the CPT. © 2009 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigates the major similarities and discrepancies among three important current decompositions proposed for the interpretation of unbalanced and/or non linear three-phase four-wire power circuits. The considered approaches were the so-called FBD Theory, the pq-Theory and the CPT. Although the methods are based on different concepts, the results obtained under ideal conditions (sinusoidal and balanced signals) are very similar. The main differences appear in the presence of unbalanced and non linear load conditions. It will be demonstrated and discussed how the choice of the voltage referential and the return conductor impedance can influence in the resulting current components, as well as, the way of interpreting a power circuit with return conductor. Under linear unbalanced conditions, both FBD and pq-Theory suggest that the some current components contain a third-order harmonic. Besides, neither pq-Theory nor FBD method are able to provide accurate information for reactive current under unbalanced and distorted conditions, what can be done by means of the CPT. © 2009 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to contribute to the discussion of defining a generalized power theory, valid for unbalanced and non linear circuits, this paper discusses the relationship and discrepancies among four modern power theories. Three-phase four-wire circuits, under different conditions, have been analyzed, since the most conflicting and intriguing interpretations take place in case of return conductor occurrence. Simulation results of different load, power supply and line conditions will be discussed in order to elucidate the author's conclusions and to provoke the readers for additional discussions. © 2010 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a new approach for optimal phasor measurement units placement for fault location on electric power distribution systems using Greedy Randomized Adaptive Search Procedure metaheuristic and Monte Carlo simulation. The optimized placement model herein proposed is a general methodology that can be used to place devices aiming to record the voltage sag magnitudes for any fault location algorithm that uses voltage information measured at a limited set of nodes along the feeder. An overhead, three-phase, three-wire, 13.8 kV, 134-node, real-life feeder model is used to evaluate the algorithm. Tests show that the results of the fault location methodology were improved thanks to the new optimized allocation of the meters pinpointed using this methodology. © 2011 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents some methodologies for reactive energy measurement, considering three modern power theories that are suitable for three-phase four-wire non-sinusoidal and unbalanced circuits. The theories were applied in some profiles collected in electrical distribution systems which have real characteristics for voltages and currents measured by commercial reactive energy meters. The experimental results are presented in order to analyze the accuracy of the methodologies, considering the standard IEEE 1459-2010 as a reference. Finally, for additional comparisons, the theories will be confronted with the modern Yokogawa WT3000 energy meter and three samples of a commercial energy meter through an experimental setup. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 15-month-old DSH cat was presented with facial deformity secondary to multiple oral and maxillofacial fractures after being struck by an automobile. Multiple wires and dental acrylics were used for fracture repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar as taxas de ativação e de clivagem de oócitos bovinos tratados com estrôncio (10mm de SrCl2), após maturação in vitro por 27-28 horas. No experimento 1, os tratamentos foram: S4 - ativação pelo estrôncio por 4 horas; S12 - ativação pelo estrôncio por 12 horas; S30 - ativação pelo estrôncio por 30 horas; e P - ativação por pulso elétrico (3 pulsos de 1,0kv/cm). No experimento 2 os tratamentos foram: PS4 - ativação combinada pelo pulso elétrico e pelo estrôncio por 4 horas; S4P - ativação pelo estrôncio por 4 horas e pelo pulso elétrico; e PS30 - ativação pelo pulso elétrico e pelo estrôncio por 30 horas. No experimento 1, todos os tratamentos apresentaram taxas similares de ativação (83-90%; P>0,05). Para clivagem, P foi melhor (53%; P<0,05) do que todos os tratamentos com estrôncio (6 a 28%). No experimento 2, o tratamento S4P apresentou melhor taxa de ativação (88%; P<0,05) do que PS4 e PS30 (60 e 68%, respectivamente). Para clivagem, observou-se o mesmo padrão, S4P (65%; P<0,05) e PS4 e PS30 (37% e 44%, respectivamente). Conclui-se que o estrôncio é capaz de ativar oócitos bovinos e sua combinação com pulso elétrico não melhora a ativação. Este é o primeiro relato demonstrando que o estrôncio ativa oócitos bovinos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho, ajustou-se um modelo matemático para quantificar o efeito do rendimento do motor elétrico sobre os custos de um sistema de bombeamento para irrigação na estrutura tarifária de energia elétrica convencional e horo-sazonal verde, bem como calcular o tempo de recuperação do capital investido no equipamento de maior rendimento. em seguida, o mesmo foi aplicado a um sistema de irrigação tipo pivô central em duas opções de rendimento do motor elétrico: 92,6% (linha padrão) e 94,3% (linha alto rendimento), sendo que o custo de aquisição do primeiro correspondeu a 70% do segundo. A potência do motor elétrico era de 100 cv. Os resultados mostraram que o modelo permitiu avaliar se um motor de alto rendimento era viável economicamente em relação ao motor-padrão em cada estrutura tarifária. Nas duas estruturas tarifárias, o motor de alto rendimento não foi viável. Na tarifa horo-sazonal verde, somente seria viável se seu rendimento fosse 4,46% superior ao do motor-padrão. Na tarifa convencional, somente seria viável se o ganho de rendimento superasse 2,71%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. Measure physical therapists' exposure to the electric and magnetic fields produced by 17 shortwave diathermy devices in physical therapy clinics in the city of Presidente Prudente, São Paulo State, Brazil. Compare the observed values with the exposure levels recommended by the International Commission on Non-ionizing Radiation Protection (ICNIRP). Observe the efficacy of Faraday cages as a means of protecting physical therapists from exposure to oscillating electric and magnetic fields.Methods. Electric and magnetic field measurements were taken at four points during actual physical therapy sessions: in proximity to the operator's pelvis and head, the devices' electrical cables, and the electrodes. The measuring equipment was a Wandel & Goltermann EMR-200.Results. The values obtained in proximity to the electrodes and cables were 10 to 30 times higher than ICNIRP's recommended occupational reference levels. In the shortwave diathermy treatment rooms with Faraday cages, the fields were even higher than in treatment rooms not so equipped-principally the magnetic field, where the values were more than 100 times higher than the ICNIRP exposure limit.Conclusions. The electric and magnetic field intensities obtained in this study are generally above the exposure levels recommend in ICNIRP standards. It was also observed that the Faraday cage offers physical therapists no protection, and instead, increases their level of exposure.