118 resultados para Electric furnaces
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
This paper analyzes the thermal storage characteristics of aluminum plates in furnaces during their heating for lamination under two sources of heat: an electrical resistance bank and a combustion process carried out with natural gas. The set of equations to model the furnace under operation with electrical energy, for air as the fluid, is presented. This supports the theoretical analysis for the system under operation with natural gas combustion products. A numerical procedure, using the software ANSYS, is applied to determine the convection heat transfer coefficients for heating by the air flow. Temperatures measured in a plate inside a real furnace are used as parameters to determine these coefficients. Then convection and radiation heat transfer coefficients are determined for the natural gas combustion products. Results are compared, indicating a possible gain of 5.5 h in relation to a 19.5 h period of conventional electrical heating per plate.
Resumo:
Technical and economic feasibility of using natural gas as a non-polluting energy source was studied. Conversion of electric ovens to gas-fired ovens for the preparation of aluminum plates for laminations was used as an example of this application. Four cases were evaluated for the use of heat derived from residual gases following combustion of the natural gas. Additionally, two possibilities are included for the use of systems of co-generation; one using an internal combustion engine, and second using a gas turbine. Results suggested that it was technically and economically feasible to convert the electric ovens considered to natural gas-operated ovens.
Resumo:
Strontium barium niobate (SBN) thin films were crystallized by conventional electric furnace annealing and by rapid-thermal annealing (RTA) at different temperatures. The average grain size of films was 70 nm and thickness around 500 nm. Using x-ray diffraction, we identified the presence of polycrystalline SBN phase for films annealed from 500 to 700 °C in both cases. Phases such as SrNb2O6 and BaNb2O6 were predominantly crystallized in films annealed at 500 °C, disappearing at higher temperatures. Dielectric and ferroelectric parameters obtained from films crystallized by conventional furnace and RTA presented essentially the same values.
Resumo:
The process of steel production emits a large quantity of greenhouse gases, specifically carbon dioxide (CO2), and the reduction of such emissions is one of the main challenges for the industry in the 21st. Century. To quantify these emissions, the Worldsteel Association (association of the 170 large steel manufacturers of the world) published a methodology (CO2 Emission Data Collection) for calculation and comparison of CO2 emissions among its members. After that, in 2010, this methodology became an ISO (International Organization for Standardization) norm. Today, the calculation of the CO2 emissions in steel making companies follow the ISO 14404-1 for units with blast furnaces and the ISO 14404-2 for units with electric furnaces. In the last years, new technologies were and continue to be developed for the steel making sector aiming at energetic improvements and greenhouse gas reductions (mainly CO2) by the several processes involved in the production of steel. This work had the objective of producing a tool to calculate the CO2 emissions for the steel making sector. An Excel spreadsheet was developed to calculate the emission intensities of CO2 of a steel plant, the Usina Presidente Vargas, of the Companhia Siderúrgica Nacional (CSN). The spreadsheet furnishes results of CO2 emissions and energetic fluxes, and simulates the benefits that some of the new technologies can give to the company. The spreadsheet calculates the emissions in two ways: a) based on the carbon fluxes that enter the unit, and b) based on the emissions of each specific process within the unit (coking, sinterization, blast furnace, among others)
Resumo:
O objetivo deste trabalho foi avaliar as taxas de ativação e de clivagem de oócitos bovinos tratados com estrôncio (10mm de SrCl2), após maturação in vitro por 27-28 horas. No experimento 1, os tratamentos foram: S4 - ativação pelo estrôncio por 4 horas; S12 - ativação pelo estrôncio por 12 horas; S30 - ativação pelo estrôncio por 30 horas; e P - ativação por pulso elétrico (3 pulsos de 1,0kv/cm). No experimento 2 os tratamentos foram: PS4 - ativação combinada pelo pulso elétrico e pelo estrôncio por 4 horas; S4P - ativação pelo estrôncio por 4 horas e pelo pulso elétrico; e PS30 - ativação pelo pulso elétrico e pelo estrôncio por 30 horas. No experimento 1, todos os tratamentos apresentaram taxas similares de ativação (83-90%; P>0,05). Para clivagem, P foi melhor (53%; P<0,05) do que todos os tratamentos com estrôncio (6 a 28%). No experimento 2, o tratamento S4P apresentou melhor taxa de ativação (88%; P<0,05) do que PS4 e PS30 (60 e 68%, respectivamente). Para clivagem, observou-se o mesmo padrão, S4P (65%; P<0,05) e PS4 e PS30 (37% e 44%, respectivamente). Conclui-se que o estrôncio é capaz de ativar oócitos bovinos e sua combinação com pulso elétrico não melhora a ativação. Este é o primeiro relato demonstrando que o estrôncio ativa oócitos bovinos.
Resumo:
Neste trabalho, ajustou-se um modelo matemático para quantificar o efeito do rendimento do motor elétrico sobre os custos de um sistema de bombeamento para irrigação na estrutura tarifária de energia elétrica convencional e horo-sazonal verde, bem como calcular o tempo de recuperação do capital investido no equipamento de maior rendimento. em seguida, o mesmo foi aplicado a um sistema de irrigação tipo pivô central em duas opções de rendimento do motor elétrico: 92,6% (linha padrão) e 94,3% (linha alto rendimento), sendo que o custo de aquisição do primeiro correspondeu a 70% do segundo. A potência do motor elétrico era de 100 cv. Os resultados mostraram que o modelo permitiu avaliar se um motor de alto rendimento era viável economicamente em relação ao motor-padrão em cada estrutura tarifária. Nas duas estruturas tarifárias, o motor de alto rendimento não foi viável. Na tarifa horo-sazonal verde, somente seria viável se seu rendimento fosse 4,46% superior ao do motor-padrão. Na tarifa convencional, somente seria viável se o ganho de rendimento superasse 2,71%.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective. Measure physical therapists' exposure to the electric and magnetic fields produced by 17 shortwave diathermy devices in physical therapy clinics in the city of Presidente Prudente, São Paulo State, Brazil. Compare the observed values with the exposure levels recommended by the International Commission on Non-ionizing Radiation Protection (ICNIRP). Observe the efficacy of Faraday cages as a means of protecting physical therapists from exposure to oscillating electric and magnetic fields.Methods. Electric and magnetic field measurements were taken at four points during actual physical therapy sessions: in proximity to the operator's pelvis and head, the devices' electrical cables, and the electrodes. The measuring equipment was a Wandel & Goltermann EMR-200.Results. The values obtained in proximity to the electrodes and cables were 10 to 30 times higher than ICNIRP's recommended occupational reference levels. In the shortwave diathermy treatment rooms with Faraday cages, the fields were even higher than in treatment rooms not so equipped-principally the magnetic field, where the values were more than 100 times higher than the ICNIRP exposure limit.Conclusions. The electric and magnetic field intensities obtained in this study are generally above the exposure levels recommend in ICNIRP standards. It was also observed that the Faraday cage offers physical therapists no protection, and instead, increases their level of exposure.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The polarization effects of in-plane electric fields and eccentricity on electronic and optical properties of semiconductor quantum rings (QRs) are discussed within the effective-mass approximation. As eccentric rings may appropriately describe real (grown or fabricated) QRs, their energy spectrum is studied. The interplay between applied electric fields and eccentricity is analysed, and their polarization effects are found to compensate for appropriate values of eccentricity and field intensity. The importance of applied fields in tailoring the properties of different nanoscale materials and structures is stressed.
Resumo:
The effects of an in-plane electric field and eccentricity on the electronic spectrum of a GaAs quantum ring in a perpendicular magnetic field are studied. The effective-mass equation is solved by two different methods: an adiabatic approximation and a diagonalization procedure after a conformal mapping. It is shown that the electric field and the eccentricity may suppress the Aharonov-Bohm oscillations of the lower energy levels. Simple expressions for the threshold energy and the number of flat energy bands are found. In the case of a thin and eccentric ring, the intensity of a critical field which compensates the main effects of eccentricity is determined. The energy spectra are found in qualitative agreement with previous experimental and theoretical works on anisotropic rings.
Resumo:
Electron quasi-stationary states in a periodic semiconductor superlattice are calculated, as linear combinations of Wannier-Kohn functions, for different values of an electric field applied along the heterostructure. A comparison with an alternative approach, which is based on the localization of quasi-stationary states, is performed. (C) 2004 Elsevier Ltd. All rights reserved.
Power performance evaluation of an electric home fan with triac-based automatic speed control system
Resumo:
In order to provide a low cost system of thermal comfort, a common model of home fan, 40 cm diameter size, had its manual four-button control system replaced by an automatic speed control. The new control system has a temperature sensor feeding a microcontroller that, by using an optic coupling, DIAC or TRIAC-based circuit, varies the RMS value of the fan motor input voltage and its speed, according to the room temperature. Over a wide range of velocity, the fan net power and the motor fan input power were measured working under both control system. The temperature of the motor stator and the voltage waveforms were observed too. Measured values analysis showed that the TRIAC-based control system makes the fan motor work at a very low power factor and efficiency values. The worst case is at low velocity range where the higher fan motor stator temperatures were registered. The poor power factor and efficiency and the harmonics signals inserted in the motor input voltage wave by the TRIAC commutation procedure are correlated.
Resumo:
The use of mean values of thermal and electric demand can be justifiable for synthesising the configuration and for estimating the economic results because it simplifies the analysis in a preliminary feasibility study of a cogeneration plant. For determining the cogeneration scheme that best fits the energetic needs of a process several cycles and combinations must be considered, and those technically feasible will be analysed according to economic models. Although interesting for a first approach, this procedure do not consider that the peaks and valleys present in the load patterns will impose additional constraints relatively to the equipment capacities. In this paper, the effects of thermal and electric load fluctuation to the cogeneration plant design were considered. An approach for modelling these load variability is proposed for comparing two competing thermal and electric parity competing schemes. A gas turbine associated to a heat recovery steam generator was then proposed and analysed for thermal- and electric-following operational strategies. Thermal-following option revealed to be more attractive for the technical and economic limits defined for this analysis. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
The distribution of natural gas is carried out by means of long ducts and intermediate compression stations to compensate the pressure drops due to friction. The natural gas compressors are usually driven by an electric motor or a gas turbine system, offering possibilities for energy management, one of these consisting in generating energy for use in-plant or to commercialize as independent power producer. It can be done by matching the natural gas demand, at the minimum pressure allowed in the reception point, and the storage capacity of the feed duct with the maximum compressor capacity, for storing the natural gas at the maximum permitted pressure. This allows the gas turbine to drive an electric generator during the time in which the decreasing pressure in duct is above the minimum acceptable by the sink unit. In this paper, a line-pack management analysis is done for an existing compression station considering its actual demand curve for determining the economic feasibility of maintaining the gas turbine system driver generating electricity in a peak and off-peak tariff structure. The potential of cost reduction from the point of view of energy resources (natural gas and electric costs) is also analyzed. (C) 2010 Elsevier Ltd. All rights reserved.