32 resultados para Efficiency versus safety

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objectives of the present study were to evaluate the safety of mixer/loaders and applicators of paraquat to maize crop by knapsack sprayers and to determine the efficacy of safety measures applied to the sprayers. Potential dermal exposure (PDE) was evaluated in 22 worker body parts. The Cu2+ cation of a copper-based fungicide was used as tracer in the spray solution. Sanitary pads and cotton gloves were used to collect the pesticide solution on the sampled body parts. It was observed that paraquat application in front of the applicator's body (0.5 and 1.0 m lance) is unsafe because PDE was 1,979.8 ml/day (for 0.5 m lance) and 1,290.4 ml/day (for 1.0 m lance) and needs 50-80% and 37-69% control of PDE respectively. Control can be achieved by the use of protective garment on the legs and feet only, which received 92-93% of the PDE. Switching the spray nozzle to the back of the operator reduced the PDE by 98% and was sufficient to make working conditions safe, while maintaining the efficiency of application and making the work lighter and more comfortable. Mixer/loaders received 86% of the PDE to the hands and the work condition was safe (MOS > 1), however impermeable gloves could be used as a further safety measure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We did a numerical investigation of the propagation of short light pulses in the region of 1.55 mu m and the conversion efficiency (CE) for the four wave mixing generation (FWM) of ordinary and dispersion decreasing fibers for use in wavelength division multiplexing (WDM) systems, Our simulations studies three different profiles, linear, hyperbolic. and constant, One conclude that for all the profiles there is decrease of the conversion efficiency with the increase in the channel separation. The hyperbolic profile present a higher efficiency of around 1000 above in magnitude compared with the others profiles at 0.2 nm of channel separation. We calculate the conversion efficiency versus the fiber length for the three profiles. The conversion efficiency for the hyperbolic profile is higher when compared to the constant and linear profiles. The other interesting point of the hyperbolic profile is that the increase of the CE in the beginning of the fiber does not show my oscillation in the CE value (log eta), which was observed for the constant and linear profiles. For all the profiles there is an increase of the conversion efficiency with the increase of the pump power. The compression factor C-i for the generated FWM signal at omega(3) was measured along the DDF's and the constant profile fibers. One can conclude that with the use of decreasing dispersion profile (DDF) fibers one can have a control of the (CE) conversion efficiency and the compression factor of the four wave mixing (FWM) generation in WDM systems. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FMVZ

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The increase in the use of natural gas in Brazil has stimulated public and private sectors to analyse the possibility of using combined cycle systems for generation of electrical energy. Gas turbine combined cycle power plants are becoming increasingly common due to their high efficiency, short lead times, and ability to meet environmental standards. Power is produced in a generator linked directly to the gas turbine. The gas turbine exhaust gases are sent to a heat recovery steam generator to produce superheated steam that can be used in a steam turbine to produce additional power. In this paper a comparative study between a 1000 MW combined cycle power plant and 1000 kW diesel power plant is presented. In first step, the energetic situation in Brazil, the needs of the electric sector modification and the needs of demand management and integrated means planning are clarified. In another step the characteristics of large and small thermoelectric power plants that use natural gas and diesel fuel, respectively, are presented. The ecological efficiency levels of each type of power plant is considered in the discussion, presenting the emissions of particulate material, sulphur dioxide (SO2), carbon dioxide (CO2) and nitrogen oxides (NOx). (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

CONTEXTO E OBJETIVO: Os tubos traqueais são dispositivos utilizados para manutenção da ventilação. A hiperinsuflação do balonete do tubo traqueal, causada pela difusão do óxido nitroso (N2O), pode determinar lesões traqueais, que se manifestam clinicamente como odinofagia, rouquidão e tosse. A lidocaína, quando injetada no balonete do tubo traqueal, difunde-se através de sua parede, determinando ação anestésica local na traquéia. O objetivo foi avaliar a efetividade e a segurança do balonete do tubo traqueal preenchido com ar comparado com o balonete preenchido com lidocaína, considerando os desfechos: sintomas cardiovasculatórios (HAS, taquicardia); odinofagia, tosse, rouquidão e tolerância ao tubo traqueal. TIPO DE ESTUDO E LOCAL: Estudo clínico prospectivo, realizado no Departamento de Anestesiologia da Faculdade de Medicina da Unesp, campus de Botucatu. MÉTODOS: A pressão do balonete do tubo traqueal foi medida, entre 50 pacientes, antes, 30, 60, 90 e 120 minutos após o início da inalação de N2O anestésico. As pacientes foram distribuídas aleatoriamente em dois grupos: Air, em que o balonete foi inflado com ar para obtenção de pressão de 20 cm H2O, e Lido, em que o balonete foi preenchido com lidocaína a 2% mais bicarbonato de sódio a 8,4% para obtenção da mesma pressão. O desconforto antes da extubação, e manifestações clínicas como dor de garganta, rouquidão e tosse foram registrados no momento da alta da unidade de cuidados pós-anestésicos, e dor de garganta e rouquidão foram avaliadas também 24 horas após a anestesia. RESULTADOS: Os valores da pressão no balonete em G2 foram significativamente menores do que os de Air em todos os tempos de estudo, a partir de 30 minutos (p < 0,001). A proporção de pacientes que reagiu ao tubo traqueal no momento da desintubação foi significantemente menor em Lido (p < 0,005). A incidência de odinofagia foi significantemente menor em Lido no primeiro dia de pós-operatório (p < 0,05). A incidência de tosse e rouquidão não diferiu entre os grupos. CONCLUSÕES: Durante ventilação artificial, empregando-se a mistura de oxigênio e N2O, a insuflação do balonete com lidocaína 2% alcalinizada impede que ocorra aumento significante da pressão no balonete e determina maior tolerância ao tubo traqueal e menor incidência de odinofagia no pós-operatório, podendo então ser considerada mais segura e com maior efetividade.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Treatment of deep-vein thrombosis (DVT) with a once-daily regimen of enoxaparin, rather than a continuous infusion of unfractionated heparin (UFH) is more convenient and allows for home care in some patients. This study was designed to compare the efficacy and safety of these two regimens for the treatment of patients with proximal lower limb DVT. Methods: 201 patients with proximal lower limb DVT from 13 centers in Brazil were randomized in an open manner to receive either enoxaparin [1.5 mg/kg subcutaneous (s.c.) OD] or intravenous (i.v.) UFH (adjusted to aPTT 1.5-2.5 times control) for 5-10 days. All patients also received warfarin (INR 2-3) for at least 3 months. The primary efficacy endpoint Was recurrent DVT (confirmed by venography or ultrasonography), and safety endpoints included bleeding and serious adverse events. The rate of pulmonary embolism (PE) was also collected. Hospitalization was at the physician's discretion. Results: Baseline patient characteristics were comparable between groups. The duration of hospital stay was significantly shorter with enoxaparin than with UFH (3 versus 7 days). In addition, 36% of patients receiving enoxaparin did not need to be hospitalized, whereas all of the patients receiving UFH were! hospitalized. The treatment duration was slightly longer with enoxaparin (8 versus 7 days). There was a nonsignificant trend toward a reduction in the rate of recurrent DVT with enoxaparin versus UFH, and similar safety. Conclusions: A once-daily regimen of enoxaparin 1.5 mg/kg subcutaneous is at least as effective and safe as conventional treatment with a continuous intravenous infusion of UFH. However, the once daily enoxaparin regimen is easier to administer (subcutaneous versus intravenous), does not require aPTT monitoring, and leads to both a reduced number of hospital admissions and an average 4-day-shorter hospital stay. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work evaluates the environmental impact resulting from the natural gas and diesel combustion in thermoelectric power plants that utilize the combined cycle technology (CC), as regarding to Brazilian conditions according to Thermopower Priority Plan JPP). In the regions where there are not natural gas the option has been the utilization of diesel and consequentily there are more emission of pollutants. The ecological efficiency concept, which evaluates by and large the environmental impact, caused by CO2, SO2, NOx and particulate matter (PM) emissions. The combustion gases of the thermoelectric power plants working with natural gas (less pollutant) and diesel (more pollutant) cause problems to the environment, for their components harm the human being life, animals and directly the plants. The resulting pollution from natural gas and diesel combustion is analyzed, considering separately the CO2, SO2, NO2 and particulate matter gas emission and comparing them with the in use international standards regarding the air quality. It can be concluded that it is possible to calculate thermoelectric power plant quantitative and qualitative environment factor, and on the ecological standpoint, for plant with total power of 41441 kW, being 27 170 kW for the gas turbine and 14271 kW for the steam turbine. The natural gas used as fuel is better than the diesel, presenting ecological efficiency of 0.944 versus 0.914 for the latter, considering a thermal efficiency of 54% for the combined cycle. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To compare the efficiency of an Aeroneb Pro vibrating plate and an Atomisor MegaHertz ultrasonic nebulizer for providing ceftazidime distal lung deposition.Design: In vitro experiments. One gram of cetazidime was nebulized in respiratory circuits and mass median aerodynamic diameter of particles generated by ultrasonic and vibrating plate nebulizers was compared using a laser velocimeter. In vivo experiments. Lung tissue concentrations and extrapulmonary depositions were measured in ten anesthetized ventilated piglets with healthy lungs that received 1 g of ceftazidime by nebulization with either an ultrasonic (n = 5), or a vibrating plate (n = 5) nebulizer.Setting: A two-bed Experimental Intensive Care Unit of a University School of Medicine.Intervention: Following sacrifice, 5 subpleural specimens were sampled in dependent and nondependent lung regions for measuring ceftazidime lung tissue concentrations by high-performance liquid chromatography.Measurements and results: Mass median aerodynamic diameters generated by both nebulizers were similar with more than 95% of the particles between 0.5 and 5 mu m. Lung tissue concentrations were 553 +/- 123 [95% confidence interval: 514-638] mu g g(-1) using ultrasonic nebulizer, and 452 +/- 172 [95% confidence interval: 376-528] mu g g(-1) using vibrating plate nebulizers (NS). Extrapulmonary depositions were, respectively, of 38 +/- 5% (ultrasonic) and 34 +/- 4% (vibrating plate) (NS).Conclusions: Vibrating plate nebulizer is comparable to ultrasonic nebulizers for ceftazidime nebulization. It may represent a new attractive technology for inhaled antibiotic therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The selection of developmentally competent human gametes may increase the efficiency of assisted reproduction. Spermatozoa and oocytes are usually assessed according to morphological criteria. Oocyte morphology can be affected by the age, genetic characteristics, and factors related to controlled ovarian stimulation. However, there is a lack of evidence in the literature concerning the effect of gonadotropin-releasing hormone (GnRH) analogues, either agonists or antagonists, on oocyte morphology. The aim of this randomized study was to investigate whether the prevalence of oocyte dysmorphism is influenced by the type of pituitary suppression used in ovarian stimulation.Methods: A total of 64 patients in the first intracytoplasmic sperm injection (ICSI) cycle were prospectively randomized to receive treatment with either a GnRH agonist with a long-term protocol (n: 32) or a GnRH antagonist with a multi-dose protocol (n: 32). Before being subjected to ICSI, the oocytes at metaphase II from both groups were morphologically analyzed under an inverted light microscope at 400x magnification. The oocytes were classified as follows: normal or with cytoplasmic dysmorphism, extracytoplasmic dysmorphism, or both. The number of dysmorphic oocytes per total number of oocytes was analyzed.Results: Out of a total of 681 oocytes, 189 (27.8 %) were morphologically normal, 220 (32.3 %) showed cytoplasmic dysmorphism, 124 (18.2%) showed extracytoplasmic alterations, and 148 (21.7%) exhibited both types of dysmorphism. No significant difference in oocyte dysmorphism was observed between the agonist- and antagonist- treated groups (P > 0.05). Analysis for each dysmorphism revealed that the most common conditions were alterations in polar body shape (31.3%) and the presence of diffuse cytoplasmic granulations (22.8%), refractile bodies (18.5%) and central cytoplasmic granulations (13.6%). There was no significant difference among individual oocyte dysmorphisms in the agonist- and antagonist-treated groups (P > 0.05).Conclusions: Our randomized data indicate that in terms of the quality of oocyte morphology, there is no difference between the antagonist multi-dose protocol and the long-term agonist protocol. If a GnRH analogue used for pituitary suppression in IVF cycles influences the prevalence of oocyte dysmorphisms, there does not appear to be a difference between the use of an agonist as opposed to an antagonist.