117 resultados para Efficiency analysis
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
This paper presents an efficiency investigation of an isolated high step-up ratio dc-dc converter aimed to be used for energy processing from low-voltage high-current energy sources, like batteries, photovoltaic modules or fuel-cells. The considered converter consists of an interleaved active clamp flyback topology combined with a voltage multiplier at the transformer secondary side capable of two different operating modes, i.e. resonant and non-resonant according to the design of the output capacitors. The main goal of this paper is to compare these two operating modes from the component losses point of view with the aim of maximize the overall converter efficiency. The approach is based on losses prediction using steady-state theoretical models (designed in Mathcad environment), taking into account both conduction and switching losses. The models are compared with steady-state simulations and experimental results considering different operating modes to validate the approach. © 2012 IEEE.
Resumo:
There is much concern about the social and environmental impacts caused by the economic growth of nations. Thus, to evaluate the socio-economic performance of nations, economists have increasingly addressed matters related to social welfare and the environment. It is within the scope of this context that this work discusses the performance of countries in the BRICS group regarding sustainable development. The objective of this study regards evaluating the efficiency of these countries in transforming productive resources and technological innovation into sustainable development. The proposed objective was achieved by using econometric tools as well as the data envelopment analysis method to then create economic, environmental, and social efficiency rankings for the BRICS countries, which enabled to carry out comparative analyses on the sustainable development of those countries. The results of such assessments can be of interest for more specific scientific explorations.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Energy efficiency has gained significant importance in recent years, mainly due to cyclical climatic conditions and current supply of natural resources. The present work deals with the procedures and requirements necessary to evaluate a building to a level of efficiency corresponding to your project and the actual implemented. To perform this analysis, we adopted the technical regulation efficiency prepared by Procel along with other agencies of the sector. The Regulation aims to create a model for the technical evaluation of the efficiency of buildings, popularize and expand the theme specification of conditions drawn up today. The building analyzed in this study was the library of UNESP, Guaratinguetá. Still, after the completion of the final efficiency analysis, are presented proposals for intervention that can improve and enhance the present situation of the building. The interventions are based on many technical factors and local conditions of climate and supply of resource. The issue of sustainability was explained in order to serve as a tool to expand the options available to upgrade a building in front of their impact on the environment
Resumo:
The study aimed to identify pharmacoeconomic studies in pharmacovigilance and to observe the economic outcomes in post-marketing surveillance. Therefore, a bibliographic survey was performed in databases Lilacs, PubMed/ Bireme. The search strategy was done by using scientific health descriptors [ "adverse drug reaction reporting systems " OR " medication errors " OR "product surveillance, postmarketing" OR " sentinel surveillance" ] AND [ " cost-benefit analysis" OR "cost efficiency analysis " OR " costs and cost analysis " OR " hospital costs " OR " cost-effectiveness " OR " cost-effectiveness evaluation " OR " drug costs " ]. Manuscripts published in the last 10 years were selected. We chose 13 articles, of which 12 corresponded to cost-benefit analysis and only one to cost-effectiveness assessment. In only one study there was no economy, all the other ones generated savings, ranging from 13.7 to 30% in spending valued service. Surveillance actions were: continuing education; active search through tracking devices and / or implementation of round; teamwork and multidisciplinary deployment; computerized security services management, enabling traceability of information and alerts. The results of the proposed actions have led to the prevention of adverse drug reactions, to decline of risks to the patient, to the reduction of inappropriate prescriptions, as well as the length of hospital stay spending valued service. Surveillance actions were: continuing education; active search through tracking devices and / or implementation of round; teamwork and multidisciplinary deployment; computerized security services management, enabling traceability of information and alerts. The results of the proposed actions have led to the prevention of adverse drug reactions, to decline of risks to the patient, to the reduction of inappropriate prescriptions, as well as the length of hospital stay
Resumo:
An analytical procedure has been developed for simultaneous determination of solvent mixture vapors to enable evaluation of occupational exposure. To determine the desorption efficiency the volatile components of the solvent mixtures were generated from a glass tube filled with glass wool. This device is easy to prepare and use. These vapors were then collected in activated charcoal tubes and analyzed by capillary gas chromatography. The method was tested with a mixture of 22 solvents, including aliphatic and aromatic hydrocarbons, alcohols, ethers, esters, and ketones, oil at low concentrations. All the components were defected. When a 99: 1 mixture of carbon disulfide-dimethylformamide was used for desorption the efficiency was > 75% for most of the solvents.
Resumo:
The bacterial spot in yellow passion fruit plants, caused by the bacteria Xanthomonas axonopodis pv. passiflorae, occurs in all producing areas of the country, and is responsible for great economic losses in the culture of passion fruit. This study aimed to test the efficiency of the silicate clay in the inhibition of the bacteria Xanthomonas axonopodis pv. passiflorae in vitro, and in both preventive and curative control of the bacterial spot in seedlings of yellow passion fruit plants. The silicate clay was added to the growth medium at concentrations of. 0.5, 1.0, 1.5 and 2.0%, placed in Petri dishes. After the culture medium was cooler, the bacterial suspension was inoculates (10(7) UFC.mL(-1)) with a handle, and left incubating at 28 degrees C for three days, and then the bacterial growth was evaluated. Subsequently, the product at the same concentrations above was sprayed on seedlings of 'Afruvec' passion fruit, as preventive or curative. The inoculation of the bacteria was made by foliar spraying of bacterial suspension (10(7) ufc.mL(-1)), 24 hours before or after the curative and preventive treatments, respectively. The severity of the disease was measured comparing each four true leaves from bottom up, with a diagrammatic scale. In the concentrations evaluated, the silicate clay inhibited both bacteria in vitro and symptoms of bacterial spot in the curative treatment. In preventive treatment, significant results were obtained using more than 1.0% of clay silicates. Based on these results, the clay silicate can be recommended, the concentration of 1.0-2.0% for the control of bacterial spot of passion fruit plants, in foliar sprays.
Resumo:
The increase in the use of natural gas in Brazil has stimulated public and private sectors to analyse the possibility of using combined cycle systems for generation of electrical energy. Gas turbine combined cycle power plants are becoming increasingly common due to their high efficiency, short lead times, and ability to meet environmental standards. Power is produced in a generator linked directly to the gas turbine. The gas turbine exhaust gases are sent to a heat recovery steam generator to produce superheated steam that can be used in a steam turbine to produce additional power. In this paper a comparative study between a 1000 MW combined cycle power plant and 1000 kW diesel power plant is presented. In first step, the energetic situation in Brazil, the needs of the electric sector modification and the needs of demand management and integrated means planning are clarified. In another step the characteristics of large and small thermoelectric power plants that use natural gas and diesel fuel, respectively, are presented. The ecological efficiency levels of each type of power plant is considered in the discussion, presenting the emissions of particulate material, sulphur dioxide (SO2), carbon dioxide (CO2) and nitrogen oxides (NOx). (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
This work aims with an approach for cogeneration plants evaluation based on thermoeconomic functional diagram analysis. The second law of thermodynamics is used to develop a methodology to analyse cogeneration systems, based on exergoeconomics evaluation. The thermoeconomic optimisation method developed is applied to allow a better configuration of the cogeneration plant associated to a university hospital. Also ecological efficiency is evaluated. The method was efficient and contributes for thermoeconomics modelling and analysis and can be applied to any sort of thermal system, especially those with combined heat and power in thermal parity. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: This study assessed masticatory efficiency and duration of the masticatory cycle in 14 asymptomatic patients with severe bone resorption. All patients had worn complete dentures for over 10 years. Recall visits were scheduled at 5 months and 1 year after receiving new dentures.Materials and Methods: Fourteen patients were evaluated in this study. The Research Diagnostic Criteria questionnaire and tests of the efficiency and duration of the masticatory cycle were performed with artificial food before, 5 months after, and 1 year after new dentures were delivered. Masticatory efficiency was assessed using a sieve system; artificial food was ground for 35 masticatory cycles and monitored by the operator.Results: Masticatory efficiency at 5 months was significantly improved for the 0.42-mm mesh. An improvement in masticatory efficiency and a reduction in mastication time were observed with the new dentures after 1 year.Conclusion: The results of this study indicated that 5 months did not allow enough time to demonstrate improved muscular capacity and ability after receiving new dentures. After 1 year, the duration of the masticatory cycle was reduced, and masticatory efficiency was significantly improved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The conventional, grinding methods in some cases are not very efficient because the arising of thermal damages in the pieces is very common. Optimization methods of cutting fluid application in the grinding zone are essential to prevent thermal problems from interaction of the wheel grains with the workpiece. surface. The optimization can happen through the correct selection of the cut parameters and development of devices that eliminate air layer effects generated around the grinding wheel. This article will collaborate with the development of an experimentation methodology which allows evaluating, comparatively, the performance of the deflectors in the cutting region to minimize the air layer effect of the high speed of the grinding wheel. The air layers make the cutting fluid jet to dissipate in the machine. An optimized nozzle was used in order to compare the results with the conventional method (without baffles or deflectors) of cutting fluid application. The results showed the high eficciency of the deflectors or baffles in the finish results. Copyright © 2006 by ABCM.
Resumo:
Brazil is the world's largest producer of sugar cane and which in the state of São Paulo concentrate the greatest amount of sugar cane field of the country. The sugar-alcohol sector has the capacity to produce sufficient thermal and electrical energy to be used in their process of production and commercialize of surplus in electricity distribution network. Therefore it is necessary to evaluate the energy efficiency and rationality within the mill. Accordingly this research proposed analyze the sugar-alcohol mill's sectors globally and individually, located in the west center of the São Paulo state, using the valuation methodology employed by the Agência Nacional de Energia Elétrica (ANEEL) in the industries that do not have systems of cogeneration. In this analysis, the hyperboloids of load and potency were applied based on the indexes of potency factor and load factor that allow estimate the efficiency and rationality. © 2013 IEEE.
Resumo:
Although an essential condition for the occurrence of human development, economic growth is not always efficiently converted into quality of life by nation-states. Accordingly, the objective of this study is to measure the social efficiency-the ability of a nation-state to convert its produced wealth into quality of life-of a set of 101 countries. To achieve this goal, the Data Envelopment Analysis method was used in its standard, cross-multiplicative and inverted form, by means of a new approach called 'triple index'. The main results indicated that the former Soviet republics and Eastern European countries stood out in terms of social efficiency. The developed countries, notwithstanding their high social indicators, did not excel in efficiency; however, the countries of south of Africa, despite having the worst social conditions, were also the most inefficient.
Resumo:
This work focuses basically on the design and analysis of simple and low cost hardware systems efficiency for temperature measurement in agricultural area. The main objective is to prove quantitatively, through statistical data analysis, to what extent a simple hardware designed with inexpensive components can be used safely in the indoor temperature measurement in farm buildings, such as greenhouses, warehouse or silos. To verify the of simple hardware efficiency, its data were compared with data from measurements with a high performance LabVIEW platform. This work proved that a simple hardware based on a microcontroller and the LM35 sensor can perform well. It presented a good accuracy but a relatively low precision that can be improved when performed some consecutive signal sampling and then used its average value. Although there are many papers that explain these components, this work has the distinction of presenting a data analysis in numerical form and using high performance systems to ensure critical data comparison.