16 resultados para ELUTING STENTS

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Solvents represent an important group of environmental pollutants to which people are exposed daily in the workplace. The physico chemical properties of solvents may result in disturbances to cellular structures, including damage to DNA. However, the effects of mixtures of solvents are not well known. Mutations caused by environmental agents are related to cancer development and other degenerative diseases. The work in a research laboratory that uses several types of solvents is equally predisposed to these hazards. In this study, we evaluated the mutagenicity of urine from 29 subjects exposed occupationally to solvents in a chemistry research laboratory and 29 subjects without occupational exposure (controls). Urine samples were collected in polyethylene containers at the end of the work shift. For the concentration and extraction of urine samples the XAD-2 resin was used with acetone as an eluting agent. Several strains of Salmonella typhimurium (TA100, TA98, TA97a, TA1535, YG1024) should be used to assess mutagenic susceptibilities among workers exposed to organic solvents. Different doses of extract (1.5; 3.0; 6.0 and 12.0 m/ equivalents of urine per plate) were tested on S. typhimurium strains TA100 and YG 1024, with and without metabolic activation. The mutagenic activity, measured in Salmonella typhimurium YGI1024 with S9 mix, was significantly greater in urine from workers than from controls (p <= 0.05). These results indicate the relevance of using biomarkers to assess the risk of occupational exposure to organic solvents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A canaliculite é uma afecção rara da via lacrimal. Os autores apresentam uma série de cinco casos tratados na Faculdade de Medicina de Botucatu-UNESP, comentam os achados à luz da literatura pertinente e tecem considerações sobre o tratamento efetuado, ressaltando que a canaliculotomia pode ter bons resultados mesmo que o canalículo não receba suturas ou moldes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To present our series of patients who underwent laparoscopic correction of iatrogenic lesions and a review of the literature.Patients and Methods: We evaluated 23 patients who underwent laparoscopic correction of iatrogenic lesions. Thirteen patients had open surgery, 6 had an endoscopic procedure, and 4 had a laparoscopic approach as the first surgical procedure. Vesicovaginal fistulas (VVF) developed in seven patients after open abdominal hysterectomies, and 1 patient presented with a VVF after ureterolithotripsy. A urethral cutaneous fistula developed in one patient after a laparoscopic resection of endometriosis nodules, and 1 patient presented with a ureterovaginal fistula after a perineoplasty. Three patients presented with encrusted ureteral stents after ureterolithotripsy. Ureteral stenosis developed in seven patients: three after open abdominal surgery, three after ureteroscopy, and one after pyeloplasty. One patient had a ureteral injury during laparoscopic partial nephrectomy, and two patients had bowel injuries after a tension-free vaginal tape procedure and a laparoscopic radical prostatectomy.Results: All patients underwent laparoscopic correction of the iatrogenic injuries. One patient had an early recurrence of a VVF, and one patient had a recurrence of a ureteral stenosis. There was one conversion to open surgery because of technical difficulties and one major bleeding event that necessitated blood transfusion. A lower limb compartmental syndrome developed in one patient.Conclusion: Despite the small number of patients and different types of surgeries performed, laparoscopic management of iatrogenic lesions seems to be feasible and safe in experienced hands. Its precise role in the management of this stressful condition still needs to be determined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim. The authors assess a modified Greenfield filter (GF) for the long-term patency, filter tilting and histopathologic alterations of the inferior vena cava (IVC).Methods. Adult sheep (n=7) underwent modified GF placement in the IVC. Cavograms were obtained every 3 months and pulmonary angiography at 12 months. Histopathologic and scanning electron microscopy (SEM) analyses were performed on the IVC explanted at 12 months.Results. Cavograms showed that all IVC were patent at the end of the study. Filter tilting occurred in 2/7 animals and extrusion of struts was not observed. Macroscopic examination at explantation showed minimal venous wall thickening. Microscopic examination showed minimal IVC fibrosis and intimal hyperplasia. SEM showed endothelium on the IVC surface at the filter implantation site and a presumed endothelial layer covering partially or totally the struts. The interface filter-IVC was covered by deposits of leucocytes and platelets. No signs of pulmonary embolism were found in all pulmonary angiograms of both groups.Conclusion. The modified filter presented good biocompatibility, stability and absence of thrombogenicity at 12 months. It presented low tendency to tilting and extrusion of struts. The long-term histopathologic alterations in vena caval wall were minimal and the appearance of the studied filters in the IVC was similar to stents placed in the arterial system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An on-line dialysis flow system coupled to inductively coupled plasma mass spectrometry to determine trace elements in serum samples by isotope dilution is presented. Isotope dilution was performed on samples incubated with enriched Cu-65, Zn-66, Se-77 and Pb-206 for 24 h at 36degreesC prior to dialysis to quantified total element concentrations. The sample and acceptor solutions flowed through the dialysis unit with cellophane membrane placed in between the compartments. The serum sample (1 mL) was left to recycle in a closed path while the acceptor solution was continuously pumped along the dialyzer channel and through a cationic AG50W X-8 resin column. After 10 min, around 70% of Na, K and Cl migrate from the sample. Three replicate injections of 0.1 mL were performed for the clean sample after each separation step. The on-line coupling of the dialyzer to ICP-MS allowed isotope dilution for total element determination either in the cleaned sample or by eluting the cations retained in the resin to be carried out. Results demonstrated no matrix effects from alkaline elements or spectral interference from ArNa+ on Cu-63, ArCl+ on Se-77 and (SO2+)-S-34 on Zn-66. The precision of isotope ratio measurements for Cu and Zn was around 1% and for Se and Pb was around 2.5%. The values found for the reference serum sample IMEP-17 were in good agreement with the certified values for Cu, Zn and Se.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and efficient method for the simultaneous gas chromatographic determination of ten organochlorine pesticides (alpha-HCH, beta-HCH, gamma-HCH, p,p'-DDT, o,p'-DDT, p,p'-DDD, p,p'-DDE, aldrin, endrin, and dieldrin) and six congeners of PCBs (PCB 28, 52, 118, 138, 153, and 180) in municipal solid waste compost is described. The procedure involves a solid-phase dispersion matrix using celite as dispersant sorbent, alumina as clean up sorbent and hexane-dichloromethane (7:3, v/v) mixture as eluting solvent. An additional purification step with copper was necessary to eliminate sulphur. Analysis of the sample was performed by GC-ECD. The method was validated with fortified samples at two concentration levels (0.025 and 0.05 mg kg(-1)). Average recovery ranged from 77 to 121% with relative standard deviation between 1 and 18%. The detection limits, which ranged from 0.003 to 0.01 mg kg-1, were lower than those established by the Baden-Wurttemberg directive (0.033 mg kg(-1)).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 24-year-old male patient was the victim of a firearm wound that penetrated the thorax. He arrived at another hospital hemodynamically unstable and was submitted to exploratory surgery by means of bithoracotomy. A lesion of the left branch of the pulmonary artery was detected and successfully repaired. He was submitted for computer-aided tomography on the fifth postoperative day, and a lesion of the mid-thoracic aorta was detected, which formed a saccular image. Considering that the patient had already been submitted to a bithoracotomy and that a direct approach to repair would involve another thoracotomy within a short period of time, endovascular treatment was chosen in our hospital. The procedure was performed under fluoroscopy. A second computer-aided tomography indicated adequate treatment of the lesion, with no indication of an endoleak. He has undergone ambulatory follow-up for 36 months without any problem related to the procedure. While endovascular treatment of the aorta has developed enormously, multicenter studies are needed to better define the long-term results of this approach. © 2008 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Fondaparinux is considered an agent with a well-established safety and efficacy profile in the treatment of non-ST segment elevation acute coronary syndromes, but when used alone, is associated to a higher incidence of thrombotic complications during invasive coronary procedures, requiring the supplementation of an anti-IIa agent. This study aimed to evaluate the efficacy and safety of percutaneous coronary intervention (PCI) in patients with non-ST segment elevation acute coronary syndromes previously treated with fondaparinux. Methods: Prospective, controlled registry enrolling 127 consecutive patients submitted to an early invasive stratification during treatment with fondaparinux, with supplementation of intravenous unfractionated heparin at a dose of 85 U/kg at the time of PCI. Results: The rate of the composite primary endpoint including death, acute myocardial infarction, stroke, stent thrombosis or emergency myocardial revascularization was 3.2%. The cumulative incidence of major bleeding and vascular complications was 3.2%. There were no cases of guidecatheter thrombosis or abrupt vessel closure. Conclusions: PCI in patients with acute coronary syndromes receiving fondaparinux is associated with a low rate of major adverse cardiovascular ischemic events and severe hemorrhagic complications. Supplementation of unfractionated heparin during the invasive procedures eliminates the risk of catheter-related thrombosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several alloys present the shape memory effect and among them, the equiatomic NiTi alloy, nitinol, is the most important one. It is usually used in several engineering applications and also in biomedical devices, in the fabrication of orthodontic wire, stents and Judet staples. Although a considerable amount of these biomedical devices is utilized in Brazil and a fraction of it is already made here, all nitinol used is bought abroad. Thus, it is important to develop the necessary know-how to fabricate NiTi wire and sheet. It would mean less importation with job creation and wealth generation for the country. In this work nitinol was obtained powder metallurgy from elemental powders of Ti and Ni using uniaxial compression and uniaxial compression followed by isostatic compression. The final densities achieved were determined by the Archimedes method. The precipitation of intermetallic secondary phases was studied and the samples were characterized by metallographic analysis, optical microscopy and X-ray diffraction. Results indicated that 50 hours sintering route showed a low amount of intermetallics, and no trace of unreacted powder. XRD and metallography at room temperature indicated B19’ as the predominant phase, which corresponds to martensite. Although density results showed little dispersion, the most dense sample was compacted under uniaxial compression and presented 4.8 g/cm3, corresponding to 20.84% porosity. Density variation was considered normal to the measurement process and independent of the compaction mode

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For some time, oral surgeons have tried several surgical procedures to improve the alveolar ridge for prosthetic appliance construction. The techniques used for this purpose are divided into four groups: submucosal vestibuloplasty; secondary epithelization; soft tissue grafting and transpositional flaps. Twenty patients who had problems to wear dentures due to unsatisfactory retention and stability were selected at the Oral and MaxilloFacial Surgery and Traumatology Clinic of Dental School of São José dos Campos. They were divided in two groups and operated by submucosal vestibuloplasty using stents and secondary epithelization vestibuloplasty by Clark's technique and were evaluated twelve months after operations in relationship of the sulcus depth. The results were obtained by clinical and radiological examination before and after surgery, and they are similar to those found in the literature reaching satisfactory functional judgement