12 resultados para ELECTROMYOGRAPHIC EVALUATION
em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"
Resumo:
CAUDA equina syndrome (CES) has long been recognized as a rare complication of spinal anesthesia.(1) CES has been described after administration of spinal anesthetics with lidocaine(2) and bupivacaine.(3) In 1991,(4) CES was reported after continuous spinal anesthesia with 1% tetracaine. In 1980, at our university hospital, six adult female patients underwent perineal gynecologic surgery using a spinal anesthetic of 2 ml tetracaine, 1.2%, in 10% glucose. The concentration of the injected tetracaine was unknown by the anesthetists. In all cases, lumbar puncture was performed at the L3-L4 interspace with a disposable spinal needle while the patients were in the sitting position. CES was first diagnosed 72 h or later postoperatively; previous diagnosis was not possible because patients had an indwelling urethral catheter. The diagnosis of CES was confirmed in all patients. During the past year, after institutional approval and informed consent, clinical, magnetic resonance imaging, electromyographic examinations, and conduction studies were performed in three of the above patients. Examinations were not possible on the other three patients because one had recently died, another could not be located, and the third refused to participate. T1 and T2 magnetic resonance image readings were obtained with Gadolinium contrast from a 0.5 Tesla General Electric apparatus (General Electric, Tokyo, Japan). Bilateral sensory and motor conduction studies of the sciatic nerve branches were obtained using a two-channel Nihon-Kohden Neuropack 2 (Nihom-Kohden Corporation, Tokyo, Japan). Electromyography was performed in accordance with conventional techniques.(5,6)
Resumo:
The rectus femoris was analysed in 10 volunteers during knee flexion and extension with the feet in normal, plantar flexion and dorsal flexion positions. Hewlett-Packard surface electrodes, an electromyographic signal amplifier, a computer equipped with an A/D conversion plaque (Model CAD 10/26), software specially designed to record and analyse the signals, Horizontal Leg Press, and electrogoniometers were used. The rectus femoris muscle showed strong potentials at the beginning of knee extension. In the simultaneous bendings of the knee and hip the activity was strong toward the end of the movement. The rectus femoris showed a similar activity both in the upper and lower platforms. As for foot positions, the rectus femoris showed the smallest potentials with the foot in plantar flexion and the largest ones with the foot in dorsal flexion.
Resumo:
Objective: The aim of this study was to assess the existence of myofunctional alterations before and after first premolar extraction in Class II/1 malocclusion patients that could endanger the long-term dental arch stability. Materials and Methods: The study was performed by means of morphological, functional and electromyographic analyses in 17 Class II/1 malocclusion patients (group T) and 17 Class I malocclusion patients (group C), both groups with 12-30-year age range (mean age: 20.93 ± 4.94 years). Results: Data analyzed statistically by Student's t-test showed a significant decrease in the maxillary and mandibular dental arch perimeters after orthodontic treatment (p<0.05). The Kruskal-Wallis test analyzed data from tongue posture at rest and during swallowing, not showing significant differences after treatment (groups Tb and Ta) (p>0.05). However, group T differed significantly from group C (p<0.05). The electromyographic data showed that the anterior right and left suprahyoid muscles acted synergistically in both groups, while having a lower myoelectric activity in group T during swallowing. Conclusions: Myofunctional alterations observed after the orthodontic treatment in Class II/1 malocclusion seemed to jeopardize the long-term orthodontic stability, making recurrence possible. Further research should be conducted to compare electromyographic data before and after orthodontic treatment in order to corroborate the results of the present investigation.
Resumo:
The aim of this study was to assess the electrical activity of the masseter and anterior temporal muscles in patients with severe bone resorption, with complete dentures worn for over ten years, and five months after having new dentures put in place. The RDC questionnaire was applied to twelve asymptomatic patients, before and five months after new dentures were put in place. The electrical activity recordings were made in the mandibular position at rest, and during maximum tooth clenching. The electrical activity of the masseter and anterior temporal muscles in the position at rest presented no statistically significant difference after five months of wearing the new complete dentures. Electrical activity during tooth clenching exhibited a statistically significant reduction only in the right temporal muscle. A period longer than five months of wearing the new complete dentures is required for adaptation and the acquisition of functional capacity.
Resumo:
The present study aimed at analyzing and comparing longitudinally the EMG (electromyographic activity) of the superior orbicularis oris muscle according to the breathing mode. The sample, 38 adolescents with Angle Class II Division 1 malocclusion with predominantly nose (PNB) or mouth (PMB) breathing, was evaluated at two different periods, with a two-year interval between them. For that purpose, a 16-channel electromyography machine was employed, which was properly calibrated in a PC equipped with an analogue-digital converter, with utilization of surface, passive and bipolar electrodes. The RMS data (root mean square) were collected at rest and in 12 movements and normalized according to time and amplitude, by the peak value of EMG, in order to allow comparisons between subjects and between periods. Comparison of the muscle function of PNB and PMB subjects at period 1 (P1), period 2 (P2) and the variation between periods (Δ) did not reveal statistically significant differences between groups (p < 0.05). However, longitudinal evaluation of the muscle function in PNB and PMB subjects demonstrated different evolutions in the percentage of required EMG for accomplishment of the movements investigated. It was possible to conclude that there are differences in the percentage of electric activity of the upper lip with the growth of the subjects according to the breathing mode.
Resumo:
This is the first study performed with an interocclusal splint with a vibrating device on patients with sleep bruxism. The purpose of the present study was to evaluate the effectiveness of the splint with vibrating device on patients who suffer from sleep bruxism through computerized electromyography (EMG) of the anterior temporal muscles. Eight male and female patients, ranging in age from 18 to 28 years, with evident signs and symptoms of bruxism were selected. The splint were made for the upper arch. The patients was treated with the interocclusal splint with a vibrating device, and submitted to EMG evaluations of the anterior temporal muscles on both sides. The evaluations were performed at the beginning of treatment and after 21 days of splint use. Electromyography was performed in an isometric contractions measuring of the temporal muscles. The following results obtained revealed that: when closing the mandible (isometric contraction), the anterior temporal muscles had an expressive reduction in electromyographic activity (p. < 0.10), so this splints were considered effective for patients who suffer from sleep bruxism. © 2009 Springer-Verlag.
Resumo:
The aim of this study was to evaluate the electromyographic and histopathological changes in skeletal muscles of dogs naturally infected by L. infantum. Twenty five mixed breed adult dogs with parasitological, molecular and serological diagnosis were selected. The evaluated muscles were: triceps brachial, extensor carpi radialis, biceps femoris and gastrocnemius. One dog had locomotor clinical signs with hind limbs paresis associated with severe muscle atrophy. Twenty-three (92%) had some type of muscular change, and in 22 (88%) such changes were directly identified by electromyography. Even without any clinical signs of the disease, 10 (40%) dogs had electromyographic and histopathological changes. Leishmania antigens were detected in muscles of four (16%) dogs. The electromyographic evaluation indicated the occurrence of chronic polymyositis in 13 (52%) dogs, the presence of both acute and chronic muscle inflammation four (16%), acute myopathy in two (8%) and absence of electromyographic abnormalities in three (12%) dogs. The most frequently observed histopathological changes were degeneration and necrosis of myofibers and inflammatory infiltration observed in 12 (48%) dogs. Other changes were decreased diameter of muscle fibers in 15 (60%) and peri or endomysial fibrosis in 14 (56%) animals. The changes observed in the present study showed that even in the absence of clinical signs, most dogs infected by Leishmania infantum have chronic polymyositis.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fabrication of occlusal splints in centric relation for temporomandibular disorders (TMD) patients is arguable, since this position has been defined for asymptomatic stomatognathic system. Thus, maximum intercuspation might be employed in patients with occlusal stability, eliminating the need for interocclusal records. This study compared occlusal splints fabricated in centric relation and maximum intercuspation in muscle pain reduction of TMD patients. Twenty patients with TMD of myogenous origin and bruxism were divided into 2 groups treated with splints in maximum intercuspation (I) or centric relation (II). Clinical, electrognathographic and electromyographic examinations were performed before and 3 months after therapy. Data were analyzed by the Student's t test. Differences at 5% level of probability were considered statistically significant. There was a remarkable reduction in pain symptomatology, without statistically significant differences (p>0.05) between the groups. There was mandibular repositioning during therapy, as demonstrated by the change in occlusal contacts on the splints. Electrognathographic examination demonstrated a significant increase in maximum left lateral movement for group I and right lateral movement for group II (p<0.05). There were no significant differences (p>0.05) in the electromyographic activities at rest after utilization of both splints. In conclusion, both occlusal splints were effective for pain control and presented similar action. The results suggest that maximum intercuspation may be used for fabrication of occlusal splints in patients with occlusal stability without large discrepancies between centric relation and maximum intercuspation. Moreover, this technique is simpler and less expensive.
Resumo:
In order to evaluate the relationship between the morphology of the upper lip and muscle activity in a sample of 38 subjects (17 males and 21 females) with Angle Class II division 1 malocclusions, cephalometric and electromyographic analyses were conducted. The sample was subdivided into either predominantly nose or mouth breathers. The individuals were evaluated at two different periods, with a 2 year interval. At the first observation, the subjects were 11 years to 14 years 11 months of age and at the second observation, 13 years 4 months to 16 years 6 months of age. Height and thickness of the upper lip were measured on lateral cephalograms with the aid of a digital pachymeter. For each individual, electromyographic records were obtained of the orbicularis oris superior muscle at rest and in a series of 12 movements. The electromyographic data were normalized as a function of amplitude, for achievement of the percentage value of each movement. Pearson and Spearman correlation tests were applied.The results showed some correlation between morphology and muscle function (at a confidence level of 95 per cent). However, as the values of the correlation coefficient (r) were too low to establish associations between variables, it was concluded that the dimensions of the upper lip are not correlated with muscle activity.
Resumo:
It was evaluated movements of lower limb in the double pulley system equipment on ten male volunteers during contraction of gastrocnemius (caput laterale ) and gluteus maximus muscles in the following movements: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. Myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. We observed weak gastrocnemius muscle activity for all movements studied. In the case of gluteus maximus, the most important potentials were observed for movement 2, while for the remaining movements the actions were of reasonable intensity. Compared to gluteus, gastrocnemius was less required for all movements.