88 resultados para Duplex Coating

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The absorption edge and the bandgap transition of sol-gel-dip-coating SnO2 thin films, deposited on quartz substrates, are evaluated from optical absorption data and temperature dependent photoconductivity spectra. Structural properties of these films help the interpretation of bandgap transition nature, since the obtained nanosized dimensions of crystallites are determinant on dominant growth direction and, thus, absorption energy. Electronic properties of the bulk and (110) and (101) surfaces are also presented, calculated by means of density functional theory applied to periodic calculations at B3LYP hybrid functional level. Experimentally obtained absorption edge is compared to the calculated energy band diagrams of bulk and (110) and (101) surfaces. The overall calculated electronic properties in conjunction with structural and electro-optical experimental data suggest that the nature of the bandgap transition is related to a combined effect of bulk and (101) surface, which presents direct bandgap transition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aqueous-based polyurethane dispersions have been widely utilized as lubricants in textile, shoes, automotive, biomaterial and many other industries because they are less aggressive to surrounding environment. In this work thin films with different thickness were deposited on biocompatible polyurethane by plasma polymerization process using diethylene glycol dimethyl ether (Diglyme) as monomer. Molecular structure of the films was analyzed by Fourier Transform Infrared spectroscopy. The spectra exhibited absorption bands of O-H (3500-3200cm(-1)), C-H (3000-2900cm(-1)), C=O (1730-1650cm(-1)), C-O and C-O-C bonds at 1200-1600cm(-1). The samples wettability was evaluated by measurements of contact angle using different liquids such as water, glycerol, poly-ethane and CMC. The polyurethane surface showed hydrophilic behavior after diglyme plasma-deposition with contact angle dropping from 85(0) to 22(0). Scanning Electron Microscopy revealed that diglyme films covered uniformly the polyurethane surfaces ensuring to it a biocompatible characteristic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the most interesting alternatives for replacement of hard chrome plating is tungsten carbide thermal spray coating applied by the high velocity oxy-fuel (HVOF) process which presents a safer, cleaner and less expensive alternative to chromium plating. The objective of this research is to compare the influence of the tungsten carbide-17cobalt (WC- 17Co) coating applied by high velocity oxy fuel (HVOF) process with that of hard-chromium electroplating on the fatigue strength and abrasive wear of AISI 4340 steel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shot peening is a surface process widely used to improve the fatigue strength of materials, through compressive residual stresses induced in their surface layers. Considering mechanical components for high responsible applications, wear and corrosion control is currently accomplished by the use of coated materials.In the case of chrome plating or hard anodizing, lower fatigue strength in comparison to uncoated parts are associated to high residual tensile stresses and microcracks density. Under constant or variable amplitude loading microcracks will propagate and cross the interface coating substrate without impediment.The aim of the present study is to analyze the influence of WC-10Ni coating applied by HVOF process on the axial fatigue strength of AISI 4340 steel. The shot peening effect on the fatigue performance of coated AISI 4340 steel was also evaluated. The fractured fatigue specimens were investigated using a scanning electron microscope in order to obtain information about the crack initiation points. (C) 2010 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fatigue failure is a result of a crack initiation and propagation, in consequence of a cyclical load. In aeronautical components as landing gear the fatigue strength is an important parameter to be considered in project, as well as the corrosion and wear resistance.The thermal sprayed HVOF technology it's normally used to protect components against wear and corrosion, and are being considerate an alternative to replace chromium by the aeronautical industry. With respect to fatigue life, the HVOF technique induces residual stress on the interface. In the case of tensile residual stresses, the initiation and propagation phases of fatigue process are accelerated; on the other hand, compressive residual stresses close to the surface may increase fatigue life. The technique to improve the coated materials fatigue strength is the shot peening process, which induces residual stress in the surface in order to delay the nucleation and propagation process.The aim of present study is to compare the influence of WC-10 Ni coating applied by HVOF on the fatigue strength of AISI 4340 steel, with and without shot peening. S-N curves were obtained in axial fatigue tests for material base, and tungsten carbide coated specimens. (C) 2010 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Currently, high-strength materials, particularly AISI 4340 steel, are used in several landing gear components. Due to the high resistance to wear and corrosion required, the components are usually coating by hard chromium. This treatment produces waste, such as Cr+ 6 (hexavalent chromium), generally after applying the coating of hard chromium which is harmful to health and the environment. The process HVOF (High-velocity-oxygen-fuel) is considered a promising technique for deposition of hard chromium alternative coatings, for example, coatings based on tungsten carbide. This technique provides high hardness and good wear strength and more resistance to fatigue when compared to AISI 4340 hard chromium coated. To minimize loss fatigue due to the process of deposition, shot peening is used to obtain a compressive residual stress. The aim of this study was to analyze the effects of the tungsten carbide thermal spray coating applied by the HVOF, in comparison to the conventional hard chromium electroplating on the AISI 4340 high strength steel behavior in fatigue. Optical microscopy and scanning electron microscopy were used to observe crack origin sites, thickness and adhesion of the coating. (C) 2010 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. Duplex scanning has been used in the evaluation of the aorta and proximal arteries of the lower extremities, but has limitations in evaluating the arteries of the leg. The utilization of ultrasonographic contrast (USC) may be helpful in improving the quality of the image in these arteries. The objective of the present study was to verify whether the USC increases the diagnostic accuracy of patency of the leg arteries and if it diminishes the time needed to perform duplex scanning.Methods. Twenty patients with critical ischemia (20 lower extremities) were examined by standard duplex scanning, duplex scanning with contrast and digital subtraction arteriography (DSA). The 3 arteries of the leg were divided into 3 segments, for a total of 9 segments per limb. Each segment was evaluated for patency in order to compare the 3 diagnostic methods. Comparison was made between standard duplex scanning and duplex scanning with contrast in terms of quality of the color-coded Doppler signal and of the spectral curve, and also of the time to perform the exams.Results. Duplex scanning with contrast was similar to arteriography in relation to patency diagnosis (p>0.3) and even superior in some of the segments. Standard duplex scanning was inferior to arteriography and to duplex scanning with contrast (p<0.001). There were improvements of 70% in intensity of the color-coded Doppler signal and 76% in the spectral curve after the utilization of contrast. The time necessary to perform the examinations was 23.7 minutes for standard duplex scanning and 16.9 minutes for duplex scanning with contrast (p<0.001).Conclusion. The use of ultrasonographic contrast increased the accuracy of the diagnosis of patency of leg arteries and diminished the time necessary for the execution of duplex scanning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. Extrinsic compression of the popliteal artery and absence of surrounding anatomical abnormalities characterize the functional popliteal artery entrapment syndrome (PAES). The diagnosis is confirmed to individuals who have typical symptoms of popliteal entrapment and occlusion or important stenosis of the popliteal artery with color duplex sonography (CDS), magnetic resonance imaging (MRI) or arteriography during active plantar flexion-extension maneuvers. However, variable result findings in normal asymptomatic subjects have raised doubts as to the validity of these tests. The purpose of this study was to compare the frequency of popliteal artery compression in 2 groups of asymptomatic subjects, athletes and non-athletes.Methods. Forty-two individuals were studied. Twenty-one subjects were indoor soccer players, and 21 were sedentary individuals. Physical activity was evaluated through questionnaires, anthropometric measurements, and cardiopulmonary exercise test. Evaluation of popliteal artery compression was performed in lower limbs with CDS, ankle-brachial index (ABI) measurements and continuous wave Doppler of the posterior tibial artery.Results. The athletes studied fulfilled the criteria of high level of physical activity whereas sedentary subjects met the criteria of low level of activity. Popliteal artery compression was observed with CDS in 6 (14.2%) studied subjects; 2 of whom (4.7%) were athletes and 4 (9.5%) were non-athletes. This difference was not statistically significant (p=0.21). Doppler of the tibial arteries and ABI measurements gave good specificity and sensibility in the identification of popliteal artery compression.Conclusion. The frequency of popliteal artery compression during maneuvers in normal subjects was 14.2% irrespective of whether or not they performed regular physical activities. Both Doppler and ABI showed good agreement with CDS and should be considered in screening popliteal arteries in individuals suspected of PAES.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. One of the major causes of chronic venous disease is venous reflux, the identification and quantification of which are important for diagnosis. Duplex scanning allows for the detection and quantification of reflux in individual veins. Evaluation of the great saphenous vein in primary varicosis is necessary for its preservation. Objective of the study is to evaluate a possible correlation between the intensity of reflux at the saphenofemoral junction, diameter alterations of the incompetent great saphenous vein and the practical effect of such correlation. Also to compare the clinical severity of the CEAP classification with such parameters.Methods. Three hundred limbs were submitted to duplex evaluation of their insufficient saphenous veins. Vein diameter was measured on five different points. Velocity and flow at reflux peak and reflux time were determined. The saphenous vein's diameters were correlated with velocity, flow and time. The three latter parameters and diameters were compared with clinical severity according to CEAP.Results. Correlation was found between the saphenous vein's diameters, velocity and flow. No correlation was observed between time and diameter in the thigh's upper and middle thirds. When comparing diameter, velocity and flow with CEAP clinical severity classification, an association was observed. The correlation between reflux time with clinical severity was weak.Conclusion. Reflux time is a good parameter for identifying the presence of reflux, but not for quantifying it. Velocity and peak flow were better parameters for evaluating reflux intensity as they were correlated with great saphenous vein alterations, and were associated with the disease's clinical severity. [Int Angiol 2010;29:323-30]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface and biomechanical analysis of titanium implant surfaces modified by laser beam with and without hydroxyapatite. Titanium implants with 3 different surfaces were inserted into the tibias of 30 rabbits: group I (GI) machined surface (control group), group II irradiated with laser (GII), and group III irradiated with laser and hydroxyapatite coating applied-biomimetic method (GIII). Topographical analysis with scanning electron microscopy was made before surgery in the tibia. These rabbits were distributed into 2 periods of observation: 4 and 8 weeks postsurgery, after which biomechanical analysis (removal torque) was conducted. Statistical analysis used the Student-Newman-Keuls method. Surface showed roughness in GII and GIII. Biomechanical analysis demonstrated values with significant differences in GII and GIII. Titanium implants modified by laser irradiation can increase osseointegration during the initial phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)