84 resultados para Doppler lidar

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Brazilian Geodetic Network started to be established in the early 40's, employing classical surveying methods, such as triangulation and trilateration. With the introduction of satellite positioning systems, such as TRANSIT and GPS, that network was densified. That data was adjusted by employing a variety of methods, yielding distortions in the network that need to be understood. In this work, we analyze and interpret study cases in an attempt to understand the distortions in the Brazilian network. For each case, we performed the network adjustment employing the GHOST software suite. The results show that the distortion is least sensitive to the removal of invar baselines in the classical network. The network would be more affected by the inexistence of Laplace stations and Doppler control points, with differences up to 4.5 m.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The central and western portion of the S̃ao Paulo State has large areas of sugar cane plantations, and due to the growing demand for biofuels, the production is increasing every year. During the harvest period some plantation areas are burnt a few hours before the manual cutting, causing significant quantities of biomass burning aerosol to be injected into the atmosphere. During August 2010, a field campaign has been carried out in Ourinhos, situated in the south-western region of S̃ao Paulo State. A 2-channel Raman Lidar system and two meteorological S-Band Doppler Radars are used to indentify and quantify the biomass burning plumes. In addiction, CALIPSO Satellite observations were used to compare the aerosol optical properties detected in that region with those retrieved by Raman Lidar system. Although the campaign yielded 30 days of measurements, this paper will be focusing only one case study, when aerosols released from nearby sugar cane fires were detected by the Lidar system during a CALIPSO overpass. The meteorological radar, installed in Bauru, approximately 110 km northeast from the experimental site, had recorded echoes (dense smoke comprising aerosols) from several fires occurring close to the Raman Lidar system, which also detected an intense load of aerosol in the atmosphere. HYSPLIT model forward trajectories presented a strong indication that both instruments have measured the same air masss parcels, corroborated with the Lidar Ratio values from the 532 nm elastic and 607 nm Raman N2 channel analyses and data retrieved from CALIPSO have indicated the predominance of aerosol from biomass burning sources. © 2011 SPIE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ObjectiveTo compare cardiac output (CO) measured by Doppler echocardiography and thermodilution techniques in spontaneously breathing dogs during continuous infusion of propofol. To do so, CO was obtained using the thermodilution method (CO(TD)) and Doppler evaluation of pulmonary flow (CO(DP)) and aortic flow (CO(DA)).Study designProspective cohort study.AnimalsEight adult dogs weighing 8.3 +/- 2.0 kg.MethodsPropofol was used for induction (7.5 +/- 1.9 mg kg-1 IV) followed by a continuous rate infusion at 0.7 mg kg-1 minute-1. The animals were positioned in left lateral recumbency on an echocardiography table that allowed for positioning of the transducer at the 3rd and 5th intercostal spaces of the left hemithorax for Doppler evaluation of pulmonary and aortic valves, respectively. CO(DP) and CO(DA) were calculated from pulmonary and aortic velocity spectra, respectively. A pulmonary artery catheter was inserted via the jugular vein and positioned inside the lumen of the pulmonary artery in order to evaluate CO(TD). The first measurement of CO(TD), CO(DP) and CO(DA) was performed 30 minutes after beginning continuous infusion (T0) and then at 15-minute intervals (T15, T30, T45 and T60). Numeric data were submitted to two-way anova for repeated measurements, Pearson's correlation coefficient and Bland & Altman analysis. Data are presented as mean +/- SD.ResultsAt T0, CO(TD) was lower than CO(DA). CO(DA) was higher than CO(TD) and CO(DP) at T30, T45 and T60. The difference between the CO(TD) and CO(DP), when all data were included, was -0.04 +/- 0.22 L minute-1 and Pearson's correlation coefficient (r) was 0.86. The difference between the CO(TD) and CO(DA) was -0.87 +/- 0.54 L minute-1 and r = 0.69. For CO(TD) and CO(DP), the difference was -0.82 +/- 0.59 L minute-1 and r = 0.61.ConclusionDoppler evaluation of pulmonary flow was a clinically acceptable method for assessing the CO in propofol-anesthetized dogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a method is proposed to allow the indirect orientation of images using photogrammetric control extracted through integration of data derived from Photogrammetry and Light Detection and Ranging (LiDAR) system. The photogrammetric control is obtained by using an inverse photogrammetric model, which allows the projection of image space straight lines onto the object space. This mathematical model is developed based on the intersection between the collinearity-based straight line and a DSM of region, derived from LiDAR data. The mathematical model used in the indirect orientation of the image is known as the model of equivalent t planes. This mathematical model is based on the equivalence between the vector normal to the projection plane in the image space and to the vector normal to the rotated projection plane in the object space. The goal of this work is to verify the quality, efficiency and potential of photogrammetric control straight lines obtained with proposed method applied to the indirect orientation of images. The quality of generated photogrammetric control was statistically available and the results showed that proposed method is promising and it has potential for the indirect orientation of images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the cardiovascular features of Ullrich-Turner's syndrome using echocardiography and magnetic resonance imaging, and to correlate them with the phenotype and karyotype of the patients. The diagnostic concordance between the 2 methods was also assessed. METHODS: Fifteen patients with the syndrome were assessed by echocardiography and magnetic resonance imaging (cardiac chambers, valves, and aorta). Their ages ranged from 10 to 28 (mean of 16.7) years. The karyotype was analyzed in 11 or 25 metaphases of peripheral blood lymphocytes, or both. RESULTS: The most common phenotypic changes were short stature and spontaneous absence of puberal development (100%); 1 patient had a cardiac murmur. The karyotypes detected were as follows: 45,X (n=7), mosaics (n=5), and deletions (n=3). No echocardiographic changes were observed. In regard to magnetic resonance imaging, coarctation and dilation of the aorta were found in 1 patient, and isolated dilation of the aorta was found in 4 patients. CONCLUSION: The frequencies of coarctation and dilation of the aorta detected on magnetic resonance imaging were similar to those reported in the literature (5.5% to 20%, and 6.3% to 29%, respectively). This confirmed the adjuvant role of magnetic resonance imaging to Doppler echocardiography for diagnosing cardiovascular alterations in patients with Ullrich-Turner's syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess structural and functional cardiac changes in asymptomatic pregnant women with chronic arterial hypertension (CAH). METHODS: One hundred pregnant women with CAH underwent conventional Doppler echocardiography. The Student t test was used to compare them with 29 normotensive pregnant women (NT) in their third gestational trimester. RESULTS: Systolic (SBP; mmHg) and diastolic (DBP; mmHg) blood pressure values were higher (p<0.001) in the CAH pregnant women (SBP: 139±19 and DBP: 92± 18) as compared with those of the NT group (SBP: 112±10 and DBP: 74±9). A significant enlargement of the left atrium (4.10±0.48 cm vs 3.6±0.3 cm; p<0.001) and of the left ventricular normalized mass (59.6±19.7 g/cm2,7 vs 41.9±3.4 g/cm2,7; p<0.001) was observed. Cardiac output (CO, L/min) and systolic volume (SV, mL) were significantly higher in the CAH group (CO: 6.0±1.54 vs 4.9±2.1, p<0.01; SV: 77.3±19.8 vs 56.5±25.8, p<0.001). CONCLUSION: Chronic hypertensive pregnant women have structural and functional cardiac changes that justify routine cardiologic assessment, even in the absence of cardiopulmonary symptoms.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo: Avaliar o efeito do tartarato de brimonidina a 0,2% tópico, instilado de 12/12 horas, na circulação retrobulbar em pacientes portadores de glaucoma. Métodos: Foram estudados os 2 olhos de 16 pacientes portadores de glaucoma primário de ângulo aberto e glaucoma crônico de ângulo estreito com iridotomia. Usando o Doppler colorido foram avaliados: velocidade sistólica máxima, velocidade diastólica final e índice de resistência das artéria central da retina, artéria ciliar posterior curta temporal e artéria oftálmica. As avaliações foram feitas antes e depois do uso da brimonidina. Resultados: O tartarato de brimonidina a 0,2% aumentou significativamente a velocidade sistólica máxima (28,24 para 34,23 cm/seg) e velocidade diastólica final (6,62 para 8,10 cm/seg) no olho direito e reduziu o índice de resistência (0,75 para 0,71) no olho esquerdo da artéria oftálmica. Conclusão: O tartarato de brimonidina 0,2% 2x/dia aumentou significativamente a velocidade sistólica máxima e velocidade diastólica final e reduziu índice de resistência da artéria oftálmica de pacientes glaucomatosos. Este efeito sugere que a brimonidina pode beneficiar pacientes glaucomatosos com insuficiência vascular na cabeça do nervo óptico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A perfusão total do fígado e suas contribuições relativas, pelo sistema portal e pela artéria hepática, podem estar alteradas por vários processos hepáticos, como doença hepato-celular difusa, neoplasia e shunts intra-hepáticos. O estudo do comportamento do fluxo sangüíneo nos vasos do fígado por meio da ultra-sonografia Doppler tem demonstrado que este é um método viável não-invasivo e de grande auxílio, principalmente na avaliação da hemodinâmica portal. São duas as modalidades de ultra-sonografia Doppler com maior aplicação na rotina para avaliação de fluxo nos vasos abdominais, o Doppler espectral e o Doppler colorido. Na doença hepática crônica, ocorre alteração da complacência hepática devido à fibrose ou à cirrose, as quais acarretam alterações vasculares, levando ao aumento da pressão venosa portal. As principais indicações desse exame são os casos em que há suspeita de hipertensão portal. A hemodinâmica portal é avaliada pela mensuração de sua área, da velocidade média, do volume de fluxo no vaso e do índice de congestão portal. Esta revisão de literatura tem como objetivo descrever os princípios físicos básicos da ultra-sonografia Doppler e sua aplicação na avaliação da hemodinâmica portal nos cães.