107 resultados para Direct Fourier Method

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Cold-formed steel members are subject to failure caused by buckling, normally under loads smaller than those corresponding to partial or total yielding of the cross section. The buckling of members in bending can be classified as local or global, and the occurrence of one or the other type is expected by the members' geometric characteristics and by the constraints and load conditions. One of the local instability modes that can characterize a member's failure is distortional buckling of the cross section occurring on its own plane and involving lateral displacements and rotations. This paper presents and discusses the procedures and results obtained from experimental tests of cold-formed steel members under bending. Forty-eight beams were carried out on members in simple lipped channel, in pairs, with 6-meter spans and loads applied by concentrated forces at every 1/3 of the span. The thickness, width and dimensions, of the stiffeners were chosen so that the instability by distortion buckling of the cross section was the principal failure mode expected. The experimental results are compared with the obtained results by using the direct strength method.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Analisar, comparativamente, a obtenção minimamente invasiva com o uso do MINI-HARVEST® e com instrumental tradicional adaptado. MÉTODO: de junho de 1996 a janeiro de 1999, 63 pacientes submetidos à cirurgia de revascularização do miocárdio tiveram suas veias safenas retiradas segundo técnica minimamente invasiva. Nos 30 primeiros pacientes da série utilizou-se método de visão direta com auxílio de dois afastadores de Langenbeck, e nos 33 restantes utilizou-se o MINI-HARVEST®. RESULTADOS: A idade média dos pacientes era de 61 ± 8,75 anos, sendo 52 homens e 11 mulheres. Quarenta e cinco pacientes eram diabéticos, 45 apresentavam sobrepeso/obesidade, 25 eram tabagistas ativos, 32 apresentavam história pregressa de infarto do miocárdio. O tempo médio de retirada da veia safena com afastadores Langenbeck foi de 34,2 ± 8,14 minutos e com o MINI-HARVEST® de 39,20 ± 9,12 minutos. A extensão de veia retirada foi similar nos dois grupos, variando de 10 a 30 cm. Houve uma deiscência superficial no grupo com afastadores de Langenbeck. Houve necessidade de reversão para método tradicional de retirada em dois casos do grupo MINI-HARVEST® e um do grupo Langenbeck. A incidência de infarto transoperatório foi 4,5% (três) no grupo Langenbeck e 3,1%(dois) no grupo MINI-HARVEST®. CONCLUSÕES: Podemos concluir que o método de obtenção de veia safena minimamente invasivo sob visão direta é efetivo e seguro, tanto com o uso de instrumentos tradicionais adaptados para este fim, como com afastadores especialmente constituídos, ressaltando-se que o MINI-HARVEST® dispensa a presença de um auxiliar.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Toxoplasmosis is a worldwide distributed zoonosis that affects man and most warm-blooded animals, with a great economic impact in animal and public health. Serum samples from nine 9-banded armadillos, three 6-banded armadillos, three coatimundis, two opossums and one nutria were submitted for anti-Toxoplasma gondii antibody detection by means of a modified direct agglutination method. Encephalic tissue of three 6-banded armadillos, one 9-banded armadillo, one coatimundi and one nutria were digested in acid pepsin solution and inoculated into Swiss mice for parasite isolation. Only one serum sample from a nine-banded armadillo and two from six-banded armadillos reacted producing titers equal to 256, 512 and 512, respectively. T gondii was isolated in two 6-banded armadillos, one of which was not positive in the serological test. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The protozoan parasite Giardia lamblia is responsible for a common intestinal infection in all regions of the world. In this study, four laboratory tests were evaluated for diagnostic reproducibility in the detection of this infection: Coprotest®, Direct modified method, Faust method and iron-hematoxylin staining. Positive diagnoses were tested for association with factors such as the age group and gender of the subject and the month when the sample was taken. Feces of 200 children in the Araraquara region (SP, Brazil) were examined by all four methods and the results compared. G. lamblia was found to be the most frequent parasite and 8.0% of the children showed giardiasis. There was no apparent correlation with gender, but most of the parasites were found in three- to five-year-olds. The highest frequency of infection occurred in January. The most reliable diagnostic results for G. lamblia were achieved by combining at least two methods of good reproducibility, i.e. Coprotest-Faust, Direct-Faust or Coprotest-Direct (A > 0.81).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Planar waveguides with controlled refractive index were produced using thin films of sol-gel derived organic-inorganic hybrids, so called di-ureasils. Spectroscopic ellipsometry was used to characterize the films thickness and refractive index. UV-laser direct-writing method was used to produce Y-splitter structures with coupling ratio of 50% without the need of photoinitiators.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to compare the efficacy of a direct clinical evaluation method with an indirect digital photographic method in assessing the quality of dental restorations. Seven parameters (color, occlusal marginal adaptation, anatomy form, roughness, occlusal marginal stain, luster, and secondary caries) were assessed in 89 Class I and Class II restorations from 36 adults using the modified US Public Health Service/Ryge criteria. Standardized photographs of the same restorations were digitally processed by Adobe Photoshop software, separated into the following four groups and assessed by two calibrated examiners: Group A: The original photograph displayed at 100%, without modifications (IMG100); Group B: Formed by images enlarged at 150% (IMG150); Group C: Formed by digital photographs displayed at 100% (mIMG100), with digital modifications (levels adjustment, shadow and highlight correction, color balance, unsharp Mask); and Group D: Formed by enlarged photographs displayed at 150% with modifications (mIMG150), with the same adjustments made to Group C. Photographs were assessed on a calibrated screen (Macbook) by two calibrated clinicians, and the results were statistically analyzed using Wilcoxon tests (SSPS 11.5) at 95% CI. Results: The photographic method produced higher reliability levels than the direct clinical method in all parameters. The evaluation of digital images is more consistent with clinical assessment when restorations present some moderate defect (Bravo) and less consistent when restorations are clinically classified as either satisfactory (Alpha) or in cases of severe defects (Charlie). Conclusion: The digital photographic method is a useful tool for assessing the quality of dental restorations, providing information that goes unnoticed with the visual-tactile clinical examination method. Additionally, when analyzing restorations using the Ryge modified criteria, the digital photographic method reveals a significant increase of defects compared to those clinically observed with the naked eye. Photography by itself, without the need for enlargement or correction, provides more information than clinical examination and can lead to unnecessary overtreatment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Block diagrams and signal-flow graphs are used to represent and to obtain the transfer function of interconnected systems. The reduction of signal-flow graphs is considered simpler than the reduction of block diagrams for systems with complex interrelationships. Signal-flow graphs reduction can be made without graphic manipulations of diagrams, and it is attractive for a computational implementation. In this paper the authors propose a computational method for direct reduction of signal-flow graphs. This method uses results presented in this paper about the calculation of literal determinants without symbolic mathematics tools. The Cramer's rule is applied for the solution of a set of linear equations, A program in MATLAB language for reduction of signal-flow graphs with the proposed method is presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In most cases, the cost of a control system increases based on its complexity. Proportional (P) controller is the simplest and most intuitive structure for the implementation of linear control systems. The difficulty to find the stability range of feedback systems with P controllers, using the Routh-Hurwitz criterion, increases with the order of the plant. For high order plants, the stability range cannot be easily obtained from the investigation of the coefficient signs in the first column of the Routh's array. A direct method for the determination of the stability range is presented. The method is easy to understand, to compute, and to offer the students a better comprehension on this subject. A program in MATLAB language, based on the proposed method, design examples, and class assessments, is provided in order to help the pedagogical issues. The method and the program enable the user to specify a decay rate and also extend to proportional-integral (PI), proportional-derivative (PD), and proportional-integral-derivative (PID) controllers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Direct expressions for the design of a lead-lag continuous compensator using the root locus method and the procedure described in the 1970 and 1990 books by Ogata are presented. These results are useful in the Ogata design method because they avoid the geometrical determination of poles and zeros, making it easier to create a computer-based design.